Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Series TitleSeries Title
-
Reading LevelReading Level
-
YearFrom:-To:
-
More FiltersMore FiltersContent TypeItem TypeIs Full-Text AvailableSubjectCountry Of PublicationPublisherSourceTarget AudienceDonorLanguagePlace of PublicationContributorsLocation
Done
Filters
Reset
276,049
result(s) for
"Laboratory Medicine"
Sort by:
Animals and Medicine
by
R. Morrison, Adrian
,
Botting, Jack
in
Animal experimentation-History
,
animal experiments
,
cancer research
2015
Animals and Medicine: The Contribution of Animal Experiments to the Control of Disease offers a detailed, scholarly historical review of the critical role animal experiments have played in advancing medical knowledge. Laboratory animals have been essential to this progress, and the knowledge gained has saved countless lives—both human and animal. Unfortunately, those opposed to using animals in research have often employed doctored evidence to suggest that the practice has impeded medical progress. This volume presents the articles Jack Botting wrote for the Research Defence Society News from 1991 to 1996, papers which provided scientists with the information needed to rebut such claims. Collected, they can now reach a wider readership interested in understanding the part of animal experiments in the history of medicine—from the discovery of key vaccines to the advancement of research on a range of diseases, among them hypertension, kidney failure and cancer. This book is essential reading for anyone curious about the role of animal experimentation in the history of science from the nineteenth century to the present.
Overlapping morphological, immunohistochemical and genetic features of superficial CD34-positive fibroblastic tumor and PRDM10-rearranged soft tissue tumor
2022
Superficial CD34-positive fibroblastic tumor (SCD34FT) is a recently recognized soft tissue tumor that is considered to be of borderline malignancy. The pathogenesis of this tumor remains incompletely understood, but it has been suggested that SCD34FT overlaps with tumors showing fusions involving the PRDM10 gene. Previous analyses of PRDM10-rearranged tumors have demonstrated that they have a distinct gene expression profile, resulting in high expression of CADM3 (also known as SynCam3), which can be detected immunohistochemically. Here, we investigated a series (n = 43) of SCD34FT or PRDM10-rearranged tumors and potential mimics (n = 226) with regard to morphological, genetic, and immunohistochemical features. The results show that SCD34FT and PRDM10-rearranged tumor are morphologically indistinguishable; 41 of 43 tumors of both entities are CADM3-positive. Hence, we suggest that they constitute a single entity, preferably referred to as SCD34FT. Expression of CADM3 was only rarely seen in other soft tissue tumors, except in tumors with Schwann cell differentiation. Thus, IHC for CADM3, in combination with the characteristic morphological features, is a valuable adjunct in the diagnosis of SCD34FT.
Journal Article
Next generation healthcare systems using soft computing techniques
\"This book provides applications of soft computing techniques related to healthcare systems and can be used as a reference guide for assessing the roles that various techniques such as machine learning, fuzzy logic, and statistical mathematics play in the advancements of smart healthcare systems. The book presents the basics as well as the advanced concepts to help beginners, as well as industry professionals get up to speed on the latest developments in healthcare systems. The book will examine descriptive, predictive, and social network techniques, as well as provide a discussion on analytical tools and the important role they play in finding solutions to problems in healthcare systems\"-- Provided by publisher.
Commutability assessment of new standard reference materials (SRMs) for determining serum total 25-hydroxyvitamin D using ligand binding and liquid chromatography–tandem mass spectrometry (LC–MS/MS) assays
by
Vogl, Christian
,
Le Goff, Caroline
,
Popp, Christian
in
25-Hydroxyvitamin D
,
25-Hydroxyvitamin D2
,
25-Hydroxyvitamin D3
2025
Commutability is where the measurement response for a reference material (RM) is the same as for an individual patient sample with the same concentration of analyte measured using two or more measurement systems. Assessment of commutability is essential when the RM is used in a calibration hierarchy or to ensure that clinical measurements are comparable across different measurement procedures and at different times. The commutability of three new Standard Reference Materials
®
(SRMs) for determining serum total 25-hydroxyvitamin D [25(OH)D], defined as the sum of 25-hydroxyvitamin D
2
[25(OH)D
2
] and 25-hydroxyvitamin D
3
[25(OH)D
3
], was assessed through an interlaboratory study. The following SRMs were assessed: (1) SRM 2969 Vitamin D Metabolites in Frozen Human Serum (Total 25-Hydroxyvitamin D Low Level), (2) SRM 2970 Vitamin D Metabolites in Frozen Human Serum (25-Hydroxyvitamin D
2
High Level), and (3) SRM 1949 Frozen Human Prenatal Serum. These SRMs represent three clinically relevant situations including (1) low levels of total 25(OH)D, (2) high level of 25(OH)D
2
, and (3) 25(OH)D levels in nonpregnant women and women during each of the three trimesters of pregnancy with changing concentrations of vitamin D-binding protein (VDBP). Twelve laboratories using 17 different ligand binding assays and eight laboratories using nine commercial and custom liquid chromatography–tandem mass spectrometry (LC–MS/MS) assays provided results in this study. Commutability of the SRMs with patient samples was assessed using the Clinical and Laboratory Standards Institute (CLSI) approach based on 95% prediction intervals or a pre-set commutability criterion and the recently introduced International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) approach based on differences in bias for the clinical and reference material samples using a commutability criterion of 8.8%. All three SRMs were deemed as commutable with all LC–MS/MS assays using both CLSI and IFCC approaches. SRM 2969 and SRM 2970 were deemed noncommutable for three and seven different ligand binding assays, respectively, when using the IFCC approach. Except for two assays, one or more of the three pregnancy levels of SRM 1949 were deemed noncommutable or inconclusive using different ligand binding assays and the commutability criterion of 8.8%. Overall, a noncommutable assessment for ligand binding assays is determined for these SRMs primarily due to a lack of assay selectivity related to 25(OH)D
2
or an increasing VDBP in pregnancy trimester materials rather than the quality of the SRMs. With results from 17 different ligand binding and nine LC–MS/MS assays, this study provides valuable knowledge for clinical laboratories to inform SRM selection when assessing 25(OH)D status in patient populations, particularly in subpopulations with low levels of 25(OH)D, high levels of 25(OH)D
2
, women only, or women who are pregnant.
Graphical Abstract
Journal Article
Links between accuracy and effectiveness of laboratory medicine equipment: use of the EUnetHTA core model to compare two analyzers by measuring HbA1c
2024
In the field of Laboratory Medicine, the evolution of knowledge and the innovation of technologies are the basis of analytical and diagnostic progress, leading to the development of new solutions based on innovative technologies. However, these advances must be accompanied by evidence of appropriateness, diagnostic effectiveness, and organizational efficiency, considering the test's first impact on patient outcomes.
The Health Technology Assessment (HTA) is a valid management tool to support Laboratory Medicine professionals in assessing technologies and which is the most appropriate to adopt. This study is an illustrative case of the application of HTA, exploiting the EUnetHTA Core Model, on two analyzers able to determine the glycated hemoglobin (Hemoglobin A1c, HbA1c), the Capillarys 2 Flex piercing analyzer and the HLC-723G11 analyzer in the Laboratory Medicine Service of the IRCCS San Raffaele Hospital (Milan, IT). The main focus is related to potential differences in methods, organizational aspects, and clinical effectiveness of these approaches for measuring HbA1c.
The EUnetHTA Core Model has proven to be the optimal method for HTA in the field of Laboratory Medicine, as it allows to highlight both the peculiarities of the methods on which the analyzers are based and the clinical efficacy of the laboratory test on specific patient populations, considering individual variations in treatment responses, assessing the potential benefits for individual patients or small groups.
This granular analysis helps provide insights into the effectiveness and value of healthcare interventions at the patient level, contributing to evidence-based decision-making in clinical practice and healthcare policy.
Journal Article
Achromatopsia: Genetics and Gene Therapy
by
Michalakis, Stylianos
,
Priglinger, Siegfried
,
Priglinger, Claudia
in
Acuity
,
Amino acids
,
Animal models
2022
Achromatopsia (ACHM), also known as rod monochromatism or total color blindness, is an autosomal recessively inherited retinal disorder that affects the cones of the retina, the type of photoreceptors responsible for high-acuity daylight vision. ACHM is caused by pathogenic variants in one of six cone photoreceptor-expressed genes. These mutations result in a functional loss and a slow progressive degeneration of cone photoreceptors. The loss of cone photoreceptor function manifests at birth or early in childhood and results in decreased visual acuity, lack of color discrimination, abnormal intolerance to light (photophobia), and rapid involuntary eye movement (nystagmus). Up to 90% of patients with ACHM carry mutations in
CNGA3
or
CNGB3
, which are the genes encoding the alpha and beta subunits of the cone cyclic nucleotide-gated (CNG) channel, respectively. No authorized therapy for ACHM exists, but research activities have intensified over the past decade and have led to several preclinical gene therapy studies that have shown functional and morphological improvements in animal models of ACHM. These encouraging preclinical data helped advance multiple gene therapy programs for
CNGA3
- and
CNGB3
-linked ACHM into the clinical phase. Here, we provide an overview of the genetic and molecular basis of ACHM, summarize the gene therapy-related research activities, and provide an outlook for their clinical application.
Journal Article
Assessment of serum total 25-hydroxyvitamin D assay commutability of Standard Reference Materials and College of American Pathologists Accuracy-Based Vitamin D (ABVD) Scheme and Vitamin D External Quality Assessment Scheme (DEQAS) materials: Vitamin D Standardization Program (VDSP) Commutability Study 2
by
Simpson, Christine
,
Clarke, Michael W
,
Sempos, Christopher T
in
25-Hydroxyvitamin D
,
Assaying
,
Binding
2021
An interlaboratory study was conducted through the Vitamin D Standardization Program (VDSP) to assess commutability of Standard Reference Materials® (SRMs) and proficiency testing/external quality assessment (PT/EQA) samples for determination of serum total 25-hydroxyvitamin D [25(OH)D] using ligand binding assays and liquid chromatography-tandem mass spectrometry (LC-MS/MS). A set of 50 single-donor serum samples were assigned target values for 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3] using reference measurement procedures (RMPs). SRM and PT/EQA samples evaluated included SRM 972a (four levels), SRM 2973, six College of American Pathologists (CAP) Accuracy-Based Vitamin D (ABVD) samples, and nine Vitamin D External Quality Assessment Scheme (DEQAS) samples. Results were received from 28 different laboratories using 20 ligand binding assays and 14 LC-MS/MS methods. Using the test assay results for total serum 25(OH)D (i.e., the sum of 25(OH)D2 and 25(OH)D3) determined for the single-donor samples and the RMP target values, the linear regression and 95% prediction intervals (PIs) were calculated. Using a subset of 42 samples that had concentrations of 25(OH)D2 below 30 nmol/L, one or more of the SRM and PT/EQA samples with high concentrations of 25(OH)D2 were deemed non-commutable using 5 of 11 unique ligand binding assays. SRM 972a (level 4), which has high exogenous concentration of 3-epi-25(OH)D3, was deemed non-commutable for 50% of the LC-MS/MS assays.
Journal Article
Standardization of serum creatinine is essential for accurate use of unbiased estimated GFR equations: evidence from three cohorts matched on renal function
by
Ebert, Natalie
,
Melsom, Toralf
,
Åkesson, Anna
in
Body mass index
,
Clinical Laboratory Medicine
,
Clinical Medicine
2022
Background
Differences in the performance of estimated glomerular filtration rate (eGFR) equations have been attributed to the mathematical form of the equations and to differences between patient demographics and measurement methods. We evaluated differences in serum creatinine (SCr) and eGFR in cohorts matched for age, sex, body mass index (BMI) and measured GFR (mGFR).
Methods
White North Americans from Minnesota (n = 1093) and the Chronic Renal Insufficiency Cohort (CRIC) (n = 1548) and White subjects from the European Kidney Function Consortium (EKFC) cohort (n = 7727) were matched for demographic patient characteristics (sex, age ± 3 years, BMI ± 2.5 kg/m2) and renal function (mGFR ± 3 ml/min/1.73 m2). SCr was measured with isotope dilution mass spectrometry (IDMS)-traceable assays in the Minnesota and EKFC cohorts and with non-standardized SCr assays recalculated to IDMS in the CRIC. The Minnesota cohort and CRIC shared a common method to measure GFR (renal clearance of iothalamate), while the EKFC cohort used a variety of exogenous markers and methods, all with recognized sufficient accuracy. We compared the SCr levels and eGFR predictions [for Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) and EKFC equations] of patients fulfilling these matching criteria.
Results
For 305 matched individuals, mean SCr (mg/dL) was not different between the Minnesota and EKFC cohorts (females 0.83 ± 0.20 versus 0.86 ± 0.23, males 1.06 ± 0.23 versus 1.12 ± 0.37; P > .05) but significantly different from the CRIC [females 1.13 ± 0.23 (P < .0001), males 1.42 ± 0.31 (P < .0001)]. The CKD-EPI equations performed better than the EKFC equation in the CRIC, while the opposite was true in the Minnesota and EKFC cohorts.
Conclusion
Significant differences in SCr concentrations between the Minnesota and EKFC cohorts versus CRIC were observed in subjects with the same level of mGFR and equal demographic characteristics and can be explained by the difference in SCr calibration.
Lay Summary
Standardization of serum creatinine (SCr) measurement is fundamental for estimating glomerular filtration rate (GFR). We used data with GFR measured by a reference method from three cohorts: Chronic Renal Insufficiency Cohort (CRIC, n = 1548), Minnesota cohort (n = 1093) and European Kidney Function Consortium cohort (EKFC; n = 7727). In the EKFC and Minnesota cohorts, SCr was measured by standardized methods, although SCr ‘calibration’ was more debatable in the CRIC. GFR was measured by the same method in the CRIC and Minnesota cohort. Then we matched 305 White subjects for sex, measured GFR (±3 ml/min/1.73 m2), age (±3 years) and body mass index (±2.5 kg/m2). From these matched subjects we showed that the association between SCr and measured GFR was quite similar between subjects from the Minnesota and EKFC cohorts, but different between the CRIC and EKFC cohort and between the Minnesota cohort and CRIC. These differences lead to discrepancies in the analysis of the performance of different creatinine-based equations.
Graphical Abstract
Graphical Abstract
Journal Article