Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Series Title
      Series Title
      Clear All
      Series Title
  • Reading Level
      Reading Level
      Clear All
      Reading Level
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Content Type
    • Item Type
    • Is Full-Text Available
    • Subject
    • Country Of Publication
    • Publisher
    • Source
    • Target Audience
    • Donor
    • Language
    • Place of Publication
    • Contributors
    • Location
257,083 result(s) for "Laboratory medicine "
Sort by:
Animals and Medicine
Animals and Medicine: The Contribution of Animal Experiments to the Control of Disease offers a detailed, scholarly historical review of the critical role animal experiments have played in advancing medical knowledge. Laboratory animals have been essential to this progress, and the knowledge gained has saved countless lives—both human and animal. Unfortunately, those opposed to using animals in research have often employed doctored evidence to suggest that the practice has impeded medical progress. This volume presents the articles Jack Botting wrote for the Research Defence Society News from 1991 to 1996, papers which provided scientists with the information needed to rebut such claims. Collected, they can now reach a wider readership interested in understanding the part of animal experiments in the history of medicine—from the discovery of key vaccines to the advancement of research on a range of diseases, among them hypertension, kidney failure and cancer. This book is essential reading for anyone curious about the role of animal experimentation in the history of science from the nineteenth century to the present.
Overlapping morphological, immunohistochemical and genetic features of superficial CD34-positive fibroblastic tumor and PRDM10-rearranged soft tissue tumor
Superficial CD34-positive fibroblastic tumor (SCD34FT) is a recently recognized soft tissue tumor that is considered to be of borderline malignancy. The pathogenesis of this tumor remains incompletely understood, but it has been suggested that SCD34FT overlaps with tumors showing fusions involving the PRDM10 gene. Previous analyses of PRDM10-rearranged tumors have demonstrated that they have a distinct gene expression profile, resulting in high expression of CADM3 (also known as SynCam3), which can be detected immunohistochemically. Here, we investigated a series (n = 43) of SCD34FT or PRDM10-rearranged tumors and potential mimics (n = 226) with regard to morphological, genetic, and immunohistochemical features. The results show that SCD34FT and PRDM10-rearranged tumor are morphologically indistinguishable; 41 of 43 tumors of both entities are CADM3-positive. Hence, we suggest that they constitute a single entity, preferably referred to as SCD34FT. Expression of CADM3 was only rarely seen in other soft tissue tumors, except in tumors with Schwann cell differentiation. Thus, IHC for CADM3, in combination with the characteristic morphological features, is a valuable adjunct in the diagnosis of SCD34FT.
Next generation healthcare systems using soft computing techniques
\"This book provides applications of soft computing techniques related to healthcare systems and can be used as a reference guide for assessing the roles that various techniques such as machine learning, fuzzy logic, and statistical mathematics play in the advancements of smart healthcare systems. The book presents the basics as well as the advanced concepts to help beginners, as well as industry professionals get up to speed on the latest developments in healthcare systems. The book will examine descriptive, predictive, and social network techniques, as well as provide a discussion on analytical tools and the important role they play in finding solutions to problems in healthcare systems\"-- Provided by publisher.
Achromatopsia: Genetics and Gene Therapy
Achromatopsia (ACHM), also known as rod monochromatism or total color blindness, is an autosomal recessively inherited retinal disorder that affects the cones of the retina, the type of photoreceptors responsible for high-acuity daylight vision. ACHM is caused by pathogenic variants in one of six cone photoreceptor-expressed genes. These mutations result in a functional loss and a slow progressive degeneration of cone photoreceptors. The loss of cone photoreceptor function manifests at birth or early in childhood and results in decreased visual acuity, lack of color discrimination, abnormal intolerance to light (photophobia), and rapid involuntary eye movement (nystagmus). Up to 90% of patients with ACHM carry mutations in CNGA3 or CNGB3 , which are the genes encoding the alpha and beta subunits of the cone cyclic nucleotide-gated (CNG) channel, respectively. No authorized therapy for ACHM exists, but research activities have intensified over the past decade and have led to several preclinical gene therapy studies that have shown functional and morphological improvements in animal models of ACHM. These encouraging preclinical data helped advance multiple gene therapy programs for CNGA3 - and CNGB3 -linked ACHM into the clinical phase. Here, we provide an overview of the genetic and molecular basis of ACHM, summarize the gene therapy-related research activities, and provide an outlook for their clinical application.
Links between accuracy and effectiveness of laboratory medicine equipment: use of the EUnetHTA core model to compare two analyzers by measuring HbA1c
In the field of Laboratory Medicine, the evolution of knowledge and the innovation of technologies are the basis of analytical and diagnostic progress, leading to the development of new solutions based on innovative technologies. However, these advances must be accompanied by evidence of appropriateness, diagnostic effectiveness, and organizational efficiency, considering the test's first impact on patient outcomes. The Health Technology Assessment (HTA) is a valid management tool to support Laboratory Medicine professionals in assessing technologies and which is the most appropriate to adopt. This study is an illustrative case of the application of HTA, exploiting the EUnetHTA Core Model, on two analyzers able to determine the glycated hemoglobin (Hemoglobin A1c, HbA1c), the Capillarys 2 Flex piercing analyzer and the HLC-723G11 analyzer in the Laboratory Medicine Service of the IRCCS San Raffaele Hospital (Milan, IT). The main focus is related to potential differences in methods, organizational aspects, and clinical effectiveness of these approaches for measuring HbA1c. The EUnetHTA Core Model has proven to be the optimal method for HTA in the field of Laboratory Medicine, as it allows to highlight both the peculiarities of the methods on which the analyzers are based and the clinical efficacy of the laboratory test on specific patient populations, considering individual variations in treatment responses, assessing the potential benefits for individual patients or small groups. This granular analysis helps provide insights into the effectiveness and value of healthcare interventions at the patient level, contributing to evidence-based decision-making in clinical practice and healthcare policy.
Assessment of serum total 25-hydroxyvitamin D assay commutability of Standard Reference Materials and College of American Pathologists Accuracy-Based Vitamin D (ABVD) Scheme and Vitamin D External Quality Assessment Scheme (DEQAS) materials: Vitamin D Standardization Program (VDSP) Commutability Study 2
An interlaboratory study was conducted through the Vitamin D Standardization Program (VDSP) to assess commutability of Standard Reference Materials® (SRMs) and proficiency testing/external quality assessment (PT/EQA) samples for determination of serum total 25-hydroxyvitamin D [25(OH)D] using ligand binding assays and liquid chromatography-tandem mass spectrometry (LC-MS/MS). A set of 50 single-donor serum samples were assigned target values for 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3] using reference measurement procedures (RMPs). SRM and PT/EQA samples evaluated included SRM 972a (four levels), SRM 2973, six College of American Pathologists (CAP) Accuracy-Based Vitamin D (ABVD) samples, and nine Vitamin D External Quality Assessment Scheme (DEQAS) samples. Results were received from 28 different laboratories using 20 ligand binding assays and 14 LC-MS/MS methods. Using the test assay results for total serum 25(OH)D (i.e., the sum of 25(OH)D2 and 25(OH)D3) determined for the single-donor samples and the RMP target values, the linear regression and 95% prediction intervals (PIs) were calculated. Using a subset of 42 samples that had concentrations of 25(OH)D2 below 30 nmol/L, one or more of the SRM and PT/EQA samples with high concentrations of 25(OH)D2 were deemed non-commutable using 5 of 11 unique ligand binding assays. SRM 972a (level 4), which has high exogenous concentration of 3-epi-25(OH)D3, was deemed non-commutable for 50% of the LC-MS/MS assays.
Assessment of serum total 25-hydroxyvitamin D assays for Vitamin D External Quality Assessment Scheme (DEQAS) materials distributed at ambient and frozen conditions
The Vitamin D External Quality Assessment Scheme (DEQAS) distributes human serum samples four times per year to over 1000 participants worldwide for the determination of total serum 25-hydroxyvitamin D [25(OH)D)]. These samples are stored at −40 °C prior to distribution and the participants are instructed to store the samples frozen at −20 °C or lower after receipt; however, the samples are shipped to participants at ambient conditions (i.e., no temperature control). To address the question of whether shipment at ambient conditions is sufficient for reliable performance of various 25(OH)D assays, the equivalence of DEQAS human serum samples shipped under frozen and ambient conditions was assessed. As part of a Vitamin D Standardization Program (VDSP) commutability study, two sets of the same nine DEQAS samples were shipped to participants at ambient temperature and frozen on dry ice. Twenty-eight laboratories participated in this study and provided 34 sets of results for the measurement of 25(OH)D using 20 ligand binding assays and 14 liquid chromatography–tandem mass spectrometry (LC–MS/MS) methods. Equivalence of the assay response for the frozen versus ambient DEQAS samples for each assay was evaluated using multi-level modeling, paired t-tests including a false discovery rate (FDR) approach, and ordinary least squares linear regression analysis of frozen versus ambient results. Using the paired t-test and confirmed by FDR testing, differences in the results for the ambient and frozen samples were found to be statistically significant at p < 0.05 for four assays (DiaSorin, DIAsource, Siemens, and SNIBE prototype). For all 14 LC–MS/MS assays, the differences in the results for the ambient- and frozen-shipped samples were not found to be significant at p < 0.05 indicating that these analytes were stable during shipment at ambient conditions. Even though assay results have been shown to vary considerably among different 25(OH)D assays in other studies, the results of this study also indicate that sample handling/transport conditions may influence 25(OH)D assay response for several assays.
Standardization of serum creatinine is essential for accurate use of unbiased estimated GFR equations: evidence from three cohorts matched on renal function
Background Differences in the performance of estimated glomerular filtration rate (eGFR) equations have been attributed to the mathematical form of the equations and to differences between patient demographics and measurement methods. We evaluated differences in serum creatinine (SCr) and eGFR in cohorts matched for age, sex, body mass index (BMI) and measured GFR (mGFR). Methods White North Americans from Minnesota (n = 1093) and the Chronic Renal Insufficiency Cohort (CRIC) (n = 1548) and White subjects from the European Kidney Function Consortium (EKFC) cohort (n = 7727) were matched for demographic patient characteristics (sex, age ± 3 years, BMI ± 2.5 kg/m2) and renal function (mGFR ± 3 ml/min/1.73 m2). SCr was measured with isotope dilution mass spectrometry (IDMS)-traceable assays in the Minnesota and EKFC cohorts and with non-standardized SCr assays recalculated to IDMS in the CRIC. The Minnesota cohort and CRIC shared a common method to measure GFR (renal clearance of iothalamate), while the EKFC cohort used a variety of exogenous markers and methods, all with recognized sufficient accuracy. We compared the SCr levels and eGFR predictions [for Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) and EKFC equations] of patients fulfilling these matching criteria. Results For 305 matched individuals, mean SCr (mg/dL) was not different between the Minnesota and EKFC cohorts (females 0.83 ± 0.20 versus 0.86 ± 0.23, males 1.06 ± 0.23 versus 1.12 ± 0.37; P > .05) but significantly different from the CRIC [females 1.13 ± 0.23 (P < .0001), males 1.42 ± 0.31 (P < .0001)]. The CKD-EPI equations performed better than the EKFC equation in the CRIC, while the opposite was true in the Minnesota and EKFC cohorts. Conclusion Significant differences in SCr concentrations between the Minnesota and EKFC cohorts versus CRIC were observed in subjects with the same level of mGFR and equal demographic characteristics and can be explained by the difference in SCr calibration. Lay Summary Standardization of serum creatinine (SCr) measurement is fundamental for estimating glomerular filtration rate (GFR). We used data with GFR measured by a reference method from three cohorts: Chronic Renal Insufficiency Cohort (CRIC, n = 1548), Minnesota cohort (n = 1093) and European Kidney Function Consortium cohort (EKFC; n = 7727). In the EKFC and Minnesota cohorts, SCr was measured by standardized methods, although SCr ‘calibration’ was more debatable in the CRIC. GFR was measured by the same method in the CRIC and Minnesota cohort. Then we matched 305 White subjects for sex, measured GFR (±3 ml/min/1.73 m2), age (±3 years) and body mass index (±2.5 kg/m2). From these matched subjects we showed that the association between SCr and measured GFR was quite similar between subjects from the Minnesota and EKFC cohorts, but different between the CRIC and EKFC cohort and between the Minnesota cohort and CRIC. These differences lead to discrepancies in the analysis of the performance of different creatinine-based equations. Graphical Abstract Graphical Abstract