Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
2,572 result(s) for "Rats, Inbred Lew"
Sort by:
Intrahepatic Vascular Anatomy in Rats and Mice—Variations and Surgical Implications
The intra-hepatic vascular anatomy in rodents, its variations and corresponding supplying and draining territories in respect to the lobar structure of the liver have not been described. We performed a detailed anatomical imaging study in rats and mice to allow for further refinement of experimental surgical approaches. LEWIS-Rats and C57Bl/6N-Mice were subjected to ex-vivo imaging using μCT. The image data were used for semi-automated segmentation to extract the hepatic vascular tree as prerequisite for 3D visualization. The underlying vascular anatomy was reconstructed, analysed and used for determining hepatic vascular territories. The four major liver lobes have their own lobar portal supply and hepatic drainage territories. In contrast, the paracaval liver is supplied by various small branches from right and caudate portal veins and drains directly into the vena cava. Variations in hepatic vascular anatomy were observed in terms of branching pattern and distance of branches to each other. The portal vein anatomy is more variable than the hepatic vein anatomy. Surgically relevant variations were primarily observed in portal venous supply. For the first time the key variations of intrahepatic vascular anatomy in mice and rats and their surgical implications were described. We showed that lobar borders of the liver do not always match vascular territorial borders. These findings are of importance for the design of new surgical procedures and for understanding eventual complications following hepatic surgery.
How Similar Are Inbred Rats? The Influence of Anatomical Variations, Shipment and Sampling Time on Experimental Surgery
Variations among inbred rats in terms of anatomy and routine laboratory values can potentially blur surgical experimental results. Therefore, a retrospective analysis aiming at investigating hepatic and perihepatic anatomical variations, liver weight, body weight, liver weight/body weight ratio (LBWR), variations in routine laboratory values, and the influence of shipment and repeated sampling was performed. In our study, liver weight of rats seemed to be strain-specific. LBWR was weakly and negatively correlated with body weight in rats. A statistically significant difference in routine blood tests was found among normal rats grouped by different body weight or shipment. Weekly repeated sampling from the same rats revealed a statistically significant difference in a blood test. In conclusion, the fact that variation among rats or their environment can blur the results of a surgical experimental study should be kept in mind.
Halofuginone attenuates osteoarthritis by inhibition of TGF-β activity and H-type vessel formation in subchondral bone
ObjectivesExamine whether osteoarthritis (OA) progression can be delayed by halofuginone in anterior cruciate ligament transection (ACLT) rodent models.Methods3-month-old male C57BL/6J (wild type; WT) mice and Lewis rats were randomised to sham-operated, ACLT-operated, treated with vehicle, or ACLT-operated, treated with halofuginone. Articular cartilage degeneration was graded using the Osteoarthritis Research Society International (OARSI)-modified Mankin criteria. Immunostaining, flow cytometry, RT-PCR and western blot analyses were conducted to detect relative protein and RNA expression. Bone micro CT (μCT) and CT-based microangiography were quantitated to detect alterations of microarchitecture and vasculature in tibial subchondral bone.ResultsHalofuginone attenuated articular cartilage degeneration and subchondral bone deterioration, resulting in substantially lower OARSI scores. Specifically, we found that proteoglycan loss and calcification of articular cartilage were significantly decreased in halofuginone-treated ACLT rodents compared with vehicle-treated ACLT controls. Halofuginone reduced collagen X (Col X), matrix metalloproteinase-13 and A disintegrin and metalloproteinase with thrombospondin motifs 5 (ADAMTS 5) and increased lubricin, collagen II and aggrecan. In parallel, halofuginone-attenuated uncoupled subchondral bone remodelling as defined by reduced subchondral bone tissue volume, lower trabecular pattern factor (Tb.pf) and increased thickness of subchondral bone plate compared with vehicle-treated ACLT controls. We found that halofuginone exerted protective effects in part by suppressing Th17-induced osteoclastic bone resorption, inhibiting Smad2/3-dependent TGF-β signalling to restore coupled bone remodelling and attenuating excessive angiogenesis in subchondral bone.ConclusionsHalofuginone attenuates OA progression by inhibition of subchondral bone TGF-β activity and aberrant angiogenesis as a potential preventive therapy for OA.
Required growth facilitators propel axon regeneration across complete spinal cord injury
Transected axons fail to regrow across anatomically complete spinal cord injuries (SCI) in adults. Diverse molecules can partially facilitate or attenuate axon growth during development or after injury 1 – 3 , but efficient reversal of this regrowth failure remains elusive 4 . Here we show that three factors that are essential for axon growth during development but are attenuated or lacking in adults—(i) neuron intrinsic growth capacity 2 , 5 – 9 , (ii) growth-supportive substrate 10 , 11 and (iii) chemoattraction 12 , 13 —are all individually required and, in combination, are sufficient to stimulate robust axon regrowth across anatomically complete SCI lesions in adult rodents. We reactivated the growth capacity of mature descending propriospinal neurons with osteopontin, insulin-like growth factor 1 and ciliary-derived neurotrophic factor before SCI 14 , 15 ; induced growth-supportive substrates with fibroblast growth factor 2 and epidermal growth factor; and chemoattracted propriospinal axons with glial-derived neurotrophic factor 16 , 17 delivered via spatially and temporally controlled release from biomaterial depots 18 , 19 , placed sequentially after SCI. We show in both mice and rats that providing these three mechanisms in combination, but not individually, stimulated robust propriospinal axon regrowth through astrocyte scar borders and across lesion cores of non-neural tissue that was over 100-fold greater than controls. Stimulated, supported and chemoattracted propriospinal axons regrew a full spinal segment beyond lesion centres, passed well into spared neural tissue, formed terminal-like contacts exhibiting synaptic markers and conveyed a significant return of electrophysiological conduction capacity across lesions. Thus, overcoming the failure of axon regrowth across anatomically complete SCI lesions after maturity required the combined sequential reinstatement of several developmentally essential mechanisms that facilitate axon growth. These findings identify a mechanism-based biological repair strategy for complete SCI lesions that could be suitable to use with rehabilitation models designed to augment the functional recovery of remodelling circuits. Stimulating the intrinsic growth capacity of neurons and providing growth-supportive substrate and chemoattraction can allow axon regrowth across anatomically complete spinal cord injuries in adult rodents.
Bioresorbable silicon electronic sensors for the brain
Electronic implants are often used in diagnosing and treating human illness, but permanent implants come with problems; here, devices are described that can sense temperature, pressure, pH or thermal characteristics, and—crucially—are fully resorbable by the body. A bioresorbable electronic interface to the brain This study reports the design, fabrication, and in vivo implementation of a silicon-based bioresorbable sensor for monitoring the pressure and temperature within the brain. Individually, all the materials that form the device were previously known to be resorbable. But this is the first demonstration of a functional sensor that completely dissolves in vivo after use with no apparent ill effects. Making the sensors completely resorbable avoids the need for surgical removal. The applications of such devices are not restricted to the brain — they can be modified for use in a range of medical conditions. Percutaneous wires were eliminated by implanting a telemetry device, though this device was not completely resorbable. Many procedures in modern clinical medicine rely on the use of electronic implants in treating conditions that range from acute coronary events to traumatic injury 1 , 2 . However, standard permanent electronic hardware acts as a nidus for infection: bacteria form biofilms along percutaneous wires, or seed haematogenously, with the potential to migrate within the body and to provoke immune-mediated pathological tissue reactions 3 , 4 . The associated surgical retrieval procedures, meanwhile, subject patients to the distress associated with re-operation and expose them to additional complications 5 , 6 , 7 , 8 . Here, we report materials, device architectures, integration strategies, and in vivo demonstrations in rats of implantable, multifunctional silicon sensors for the brain, for which all of the constituent materials naturally resorb via hydrolysis and/or metabolic action 9 , 10 , 11 , 12 , eliminating the need for extraction. Continuous monitoring of intracranial pressure and temperature illustrates functionality essential to the treatment of traumatic brain injury 2 , 13 ; the measurement performance of our resorbable devices compares favourably with that of non-resorbable clinical standards. In our experiments, insulated percutaneous wires connect to an externally mounted, miniaturized wireless potentiostat for data transmission. In a separate set-up, we connect a sensor to an implanted (but only partially resorbable) data-communication system, proving the principle that there is no need for any percutaneous wiring. The devices can be adapted to sense fluid flow, motion, pH or thermal characteristics, in formats that are compatible with the body’s abdomen and extremities, as well as the deep brain, suggesting that the sensors might meet many needs in clinical medicine.
An organoid-based organ-repurposing approach to treat short bowel syndrome
The small intestine is the main organ for nutrient absorption, and its extensive resection leads to malabsorption and wasting conditions referred to as short bowel syndrome (SBS). Organoid technology enables an efficient expansion of intestinal epithelium tissue in vitro 1 , but reconstruction of the whole small intestine, including the complex lymphovascular system, has remained challenging 2 . Here we generate a functional small intestinalized colon (SIC) by replacing the native colonic epithelium with ileum-derived organoids. We first find that xenotransplanted human ileum organoids maintain their regional identity and form nascent villus structures in the mouse colon. In vitro culture of an organoid monolayer further reveals an essential role for luminal mechanistic flow in the formation of villi. We then develop a rat SIC model by repositioning the SIC at the ileocaecal junction, where the epithelium is exposed to a constant luminal stream of intestinal juice. This anatomical relocation provides the SIC with organ structures of the small intestine, including intact vasculature and innervation, villous structures, and the lacteal (a fat-absorbing lymphatic structure specific to the small intestine). The SIC has absorptive functions and markedly ameliorates intestinal failure in a rat model of SBS, whereas transplantation of colon organoids instead of ileum organoids invariably leads to mortality. These data provide a proof of principle for the use of intestinal organoids for regenerative purposes, and offer a feasible strategy for SBS treatment. In a rat model of short bowel syndrome, transplantation of small intestinal organoids into the colon partially restores intestinal function and improves survival—a proof of principle that organoid transplantation might have therapeutic benefit.
Neuroprosthetic baroreflex controls haemodynamics after spinal cord injury
Spinal cord injury (SCI) induces haemodynamic instability that threatens survival 1 – 3 , impairs neurological recovery 4 , 5 , increases the risk of cardiovascular disease 6 , 7 , and reduces quality of life 8 , 9 . Haemodynamic instability in this context is due to the interruption of supraspinal efferent commands to sympathetic circuits located in the spinal cord 10 , which prevents the natural baroreflex from controlling these circuits to adjust peripheral vascular resistance. Epidural electrical stimulation (EES) of the spinal cord has been shown to compensate for interrupted supraspinal commands to motor circuits below the injury 11 , and restored walking after paralysis 12 . Here, we leveraged these concepts to develop EES protocols that restored haemodynamic stability after SCI. We established a preclinical model that enabled us to dissect the topology and dynamics of the sympathetic circuits, and to understand how EES can engage these circuits. We incorporated these spatial and temporal features into stimulation protocols to conceive a clinical-grade biomimetic haemodynamic regulator that operates in a closed loop. This ‘neuroprosthetic baroreflex’ controlled haemodynamics for extended periods of time in rodents, non-human primates and humans, after both acute and chronic SCI. We will now conduct clinical trials to turn the neuroprosthetic baroreflex into a commonly available therapy for people with SCI. An epidural spinal cord stimulation system regulates blood pressure in the acute and chronic phases of spinal cord injury.
Inhibition of TGF-β signaling in mesenchymal stem cells of subchondral bone attenuates osteoarthritis
Osteoarthritis has been believed to be caused by improper mechanical function of articular joints. Xu Cao and his colleagues now show that this mechanical process leads to upregulation of transforming growth factor β1 activity in mesenchymal stem cells of subchondral bone, resulting in aberrant bone formation, further destabilization of the joint and ultimately the onset of the disease. Osteoarthritis is a highly prevalent and debilitating joint disorder. There is no effective medical therapy for the condition because of limited understanding of its pathogenesis. We show that transforming growth factor β1 (TGF-β1) is activated in subchondral bone in response to altered mechanical loading in an anterior cruciate ligament transection (ACLT) mouse model of osteoarthritis. TGF-β1 concentrations are also high in subchondral bone from humans with osteoarthritis. High concentrations of TGF-β1 induced formation of nestin-positive mesenchymal stem cell (MSC) clusters, leading to formation of marrow osteoid islets accompanied by high levels of angiogenesis. We found that transgenic expression of active TGF-β1 in osteoblastic cells induced osteoarthritis, whereas inhibition of TGF-β activity in subchondral bone attenuated the degeneration of articular cartilage. In particular, knockout of the TGF-β type II receptor (TβRII) in nestin-positive MSCs led to less development of osteoarthritis relative to wild-type mice after ACLT. Thus, high concentrations of active TGF-β1 in subchondral bone seem to initiate the pathological changes of osteoarthritis, and inhibition of this process could be a potential therapeutic approach to treating this disease.
Cortico–reticulo–spinal circuit reorganization enables functional recovery after severe spinal cord contusion
Severe spinal cord contusions interrupt nearly all brain projections to lumbar circuits producing leg movement. Failure of these projections to reorganize leads to permanent paralysis. Here we modeled these injuries in rodents. A severe contusion abolished all motor cortex projections below injury. However, the motor cortex immediately regained adaptive control over the paralyzed legs during electrochemical neuromodulation of lumbar circuits. Glutamatergic reticulospinal neurons with residual projections below the injury relayed the cortical command downstream. Gravity-assisted rehabilitation enabled by the neuromodulation therapy reinforced these reticulospinal projections, rerouting cortical information through this pathway. This circuit reorganization mediated a motor cortex–dependent recovery of natural walking and swimming without requiring neuromodulation. Cortico–reticulo–spinal circuit reorganization may also improve recovery in humans.
Protective efficacy of in vitro synthesized, specific mRNA vaccines against influenza A virus infection
Petsch et al . apply mRNA vaccination for the first time to infectious disease, demonstrating immunogenicity and/or protective effects against influenza virus in mice, ferrets and pigs. Despite substantial improvements, influenza vaccine production—and availability—remain suboptimal. Influenza vaccines based on mRNA may offer a solution as sequence-matched, clinical-grade material could be produced reliably and rapidly in a scalable process, allowing quick response to the emergence of pandemic strains. Here we show that mRNA vaccines induce balanced, long-lived and protective immunity to influenza A virus infections in even very young and very old mice and that the vaccine remains protective upon thermal stress. This vaccine format elicits B and T cell–dependent protection and targets multiple antigens, including the highly conserved viral nucleoprotein, indicating its usefulness as a cross-protective vaccine. In ferrets and pigs, mRNA vaccines induce immunological correlates of protection and protective effects similar to those of a licensed influenza vaccine in pigs. Thus, mRNA vaccines could address substantial medical need in the area of influenza prophylaxis and the broader realm of anti-infective vaccinology.