MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Accuracy of 10 MHz ultrasonography for evaluation of posterior lens capsule in traumatic cataract
Accuracy of 10 MHz ultrasonography for evaluation of posterior lens capsule in traumatic cataract
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Accuracy of 10 MHz ultrasonography for evaluation of posterior lens capsule in traumatic cataract
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Accuracy of 10 MHz ultrasonography for evaluation of posterior lens capsule in traumatic cataract
Accuracy of 10 MHz ultrasonography for evaluation of posterior lens capsule in traumatic cataract

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Accuracy of 10 MHz ultrasonography for evaluation of posterior lens capsule in traumatic cataract
Accuracy of 10 MHz ultrasonography for evaluation of posterior lens capsule in traumatic cataract
Journal Article

Accuracy of 10 MHz ultrasonography for evaluation of posterior lens capsule in traumatic cataract

2024
Request Book From Autostore and Choose the Collection Method
Overview
Purpose To investigate the performance of 10 MHz ultrasonography in detecting posterior lens capsule defects before traumatic cataract surgery. Methods This retrospective analysis includes patients with traumatic cataracts who underwent cataract surgery. Preoperative 10 MHz ultrasonography was performed to evaluate whether the posterior lens capsule was defective or intact, and the results were compared to the intraoperative findings. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and kappa were calculated. Results The study included 140 eyes of 140 patients. There were 68 eyes with closed-globe injuries and 72 eyes with open-globe injuries. The sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and kappa of 10 MHz ultrasonography was 86.76%, 90.28%, 89.39%, 87.84%, 88.57% and 0.771, respectively. The accuracy was 86.11% and 91.18% in open-globe and closed-globe injury groups, respectively. Conclusion The accuracy of 10 MHz ultrasonography in evaluating the posterior lens capsule in traumatic cataracts is high. Preoperative 10 MHz ultrasonography would help to make an appropriate surgical plan.