MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Energy‐based devices and hyaluronic acid filler, polymer filler, and threads: Cadaveric study
Energy‐based devices and hyaluronic acid filler, polymer filler, and threads: Cadaveric study
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Energy‐based devices and hyaluronic acid filler, polymer filler, and threads: Cadaveric study
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Energy‐based devices and hyaluronic acid filler, polymer filler, and threads: Cadaveric study
Energy‐based devices and hyaluronic acid filler, polymer filler, and threads: Cadaveric study

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Energy‐based devices and hyaluronic acid filler, polymer filler, and threads: Cadaveric study
Energy‐based devices and hyaluronic acid filler, polymer filler, and threads: Cadaveric study
Journal Article

Energy‐based devices and hyaluronic acid filler, polymer filler, and threads: Cadaveric study

2024
Request Book From Autostore and Choose the Collection Method
Overview
Introduction The objective of this experiment was to investigate the thermal effects on hyaluronic acid fillers, PCL fillers, and PDO threads when exposed to controlled heat. This study aims to provide insights into how these materials respond to thermal energy, which is crucial for safe and effective cosmetic procedures involving combined modalities. Materials and Methods Cadaveric tissue was utilized to simulate clinical conditions. Hyaluronic acid fillers were injected at approximately 1 mm and 5 mm thicknesses, with variations in G' value (high and low). PCL fillers were similarly injected in 1 mm and 5 mm thicknesses. PDO threads were also inserted. All materials were injected at a depth of 2 cm. A thermometer was used to measure heat penetration, and a multi‐wavelength laser was applied to the tissue. The temperature was maintained at 60°C for 5 min to assess whether heat penetrated more than 3 cm in thickness. Observations were made regarding the heat distribution and any physical changes in the fillers and threads. Results In thick layers, heat accumulated above the PCL filler without penetrating deeper layers. In thin layers, heat penetration was observed. For the HA fillers, heat energy was not blocked, regardless of the G' value or thickness. For the threads, no significant heat blockage effect was observed. For all materials, no visual changes were detected in any of the materials due to temperature exposure. Discussion The findings suggest that the thickness and composition of fillers significantly influence heat penetration. Thick PCL fillers act as a thermal barrier, whereas thin PCL fillers allow deeper heat penetration. Hyaluronic acid fillers do not impede heat transfer, regardless of their physical properties. PDO threads do not exhibit any notable thermal resistance. These insights are essential for optimizing the safety and efficacy of combined filler and energy‐based device treatments in esthetic medicine.