MbrlCatalogueTitleDetail

Do you wish to reserve the book?
An optimized approach for right atrial flutter ablation: a post hoc analysis of the AURUM 8 study
An optimized approach for right atrial flutter ablation: a post hoc analysis of the AURUM 8 study
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
An optimized approach for right atrial flutter ablation: a post hoc analysis of the AURUM 8 study
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
An optimized approach for right atrial flutter ablation: a post hoc analysis of the AURUM 8 study
An optimized approach for right atrial flutter ablation: a post hoc analysis of the AURUM 8 study

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
An optimized approach for right atrial flutter ablation: a post hoc analysis of the AURUM 8 study
An optimized approach for right atrial flutter ablation: a post hoc analysis of the AURUM 8 study
Journal Article

An optimized approach for right atrial flutter ablation: a post hoc analysis of the AURUM 8 study

2017
Request Book From Autostore and Choose the Collection Method
Overview
Purpose Radiofrequency catheter ablation of typical atrial flutter can vary largely in duration from patient to patient. The purpose of this work was to determine optimal combination of ablation settings leading to the highest procedural efficacy. Methods Our retrospective multivariate analysis comprised 448 patients undergoing atrial flutter ablation with nonirrigated 8-mm catheters at 19 clinical centers. Four procedural variables were included in the prognostic model: preset maximum temperature, preset maximum power, catheter-tip material (gold vs. platinum-iridium), and ablation technique (maximum voltage-guided vs. conventional anatomical approach). Univariate and multivariate analyses were performed using the logistic regression (for acute ablation success) and Cox constant proportional hazard models (for cumulative ablation time). Results Significant multivariate predictors of acute ablation success were a higher preset maximum temperature (odds 1.083 per 1 °C, P  < 0.05) and gold-tip catheter (odds 2.096, P  < 0.05). Predictors of cumulative ablation time were the maximum voltage-guided ablation technique (hazard ratio 1.856, P  < 0.001), higher preset maximum temperature (hazard ratio 1.039 per 1 °C, P  < 0.001), and gold-tip catheter (hazard ratio 1.225, P  < 0.05). The combination of optimal settings (70 °C, 70 W, gold-tip catheter, maximum voltage-guided technique) increased the acute success rate from 91.7 % (for the entire study cohort) to 100 %, and reduced median cumulative ablation time from 8.3 to 4.3 min, median total procedure duration from 76 to 55 min, and median fluoroscopy time from 14 to 7 min. Conclusions The combination of maximum voltage-guided gold-tip ablation at 70 °C and 70 W was associated with 100 % ablation success and minimal ablation times for nonirrigated ablation of atrial flutter.