Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Comparison of Adhesion of Immortalized Human Iris-Derived Cells and Fibronectin on Phakic Intraocular Lenses Made of Different Polymer Base Materials
by
Yamamoto, Naoki
, Horai, Rie
, Ichikawa, Kazuo
, Tanaka, Yoshiki
, Ichikawa, Kei
, Kato, Yu
in
Cataracts
/ Cell adhesion
/ Cell adhesion & migration
/ Cell Adhesion - physiology
/ Cell adhesion molecules
/ Cell growth
/ Collagen
/ collamer
/ Comparative analysis
/ Contact angle
/ Contact lenses
/ Digital cameras
/ Ethics
/ Experiments
/ fibronectin (FN)
/ Fibronectins - analysis
/ Foreign bodies
/ Glaucoma
/ Humans
/ Immune system
/ implantable contact lens (ICL)
/ implantable phakic contact lens (IPCL)
/ Intraocular lenses
/ LENTIS comfort
/ Materials
/ Medical research
/ Patients
/ phakic implantable contact lens (Phakic-ICL)
/ Phakic Intraocular Lenses - adverse effects
/ Phakic Intraocular Lenses - standards
/ Physiological aspects
/ Polymers
/ Proteins
2025
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Comparison of Adhesion of Immortalized Human Iris-Derived Cells and Fibronectin on Phakic Intraocular Lenses Made of Different Polymer Base Materials
by
Yamamoto, Naoki
, Horai, Rie
, Ichikawa, Kazuo
, Tanaka, Yoshiki
, Ichikawa, Kei
, Kato, Yu
in
Cataracts
/ Cell adhesion
/ Cell adhesion & migration
/ Cell Adhesion - physiology
/ Cell adhesion molecules
/ Cell growth
/ Collagen
/ collamer
/ Comparative analysis
/ Contact angle
/ Contact lenses
/ Digital cameras
/ Ethics
/ Experiments
/ fibronectin (FN)
/ Fibronectins - analysis
/ Foreign bodies
/ Glaucoma
/ Humans
/ Immune system
/ implantable contact lens (ICL)
/ implantable phakic contact lens (IPCL)
/ Intraocular lenses
/ LENTIS comfort
/ Materials
/ Medical research
/ Patients
/ phakic implantable contact lens (Phakic-ICL)
/ Phakic Intraocular Lenses - adverse effects
/ Phakic Intraocular Lenses - standards
/ Physiological aspects
/ Polymers
/ Proteins
2025
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Comparison of Adhesion of Immortalized Human Iris-Derived Cells and Fibronectin on Phakic Intraocular Lenses Made of Different Polymer Base Materials
by
Yamamoto, Naoki
, Horai, Rie
, Ichikawa, Kazuo
, Tanaka, Yoshiki
, Ichikawa, Kei
, Kato, Yu
in
Cataracts
/ Cell adhesion
/ Cell adhesion & migration
/ Cell Adhesion - physiology
/ Cell adhesion molecules
/ Cell growth
/ Collagen
/ collamer
/ Comparative analysis
/ Contact angle
/ Contact lenses
/ Digital cameras
/ Ethics
/ Experiments
/ fibronectin (FN)
/ Fibronectins - analysis
/ Foreign bodies
/ Glaucoma
/ Humans
/ Immune system
/ implantable contact lens (ICL)
/ implantable phakic contact lens (IPCL)
/ Intraocular lenses
/ LENTIS comfort
/ Materials
/ Medical research
/ Patients
/ phakic implantable contact lens (Phakic-ICL)
/ Phakic Intraocular Lenses - adverse effects
/ Phakic Intraocular Lenses - standards
/ Physiological aspects
/ Polymers
/ Proteins
2025
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Comparison of Adhesion of Immortalized Human Iris-Derived Cells and Fibronectin on Phakic Intraocular Lenses Made of Different Polymer Base Materials
Journal Article
Comparison of Adhesion of Immortalized Human Iris-Derived Cells and Fibronectin on Phakic Intraocular Lenses Made of Different Polymer Base Materials
2025
Request Book From Autostore
and Choose the Collection Method
Overview
Background and Objectives: Posterior chamber phakic implantable contact lenses (Phakic-ICL) are widely used for refractive correction due to their efficacy and safety, including minimal corneal endothelial cell loss. The Collamer-based EVO+ Visian implantable contact lens (ICL), manufactured from Collamer, which is a blend of collagen and hydroxyethyl methacrylate (HEMA), has demonstrated excellent long-term biocompatibility and optical clarity. Recently, hydrophilic acrylic Phakic-ICLs, such as the Implantable Phakic Contact Lens (IPCL), have been introduced. This study investigated the material differences among Phakic-ICLs and their interaction with fibronectin (FN), which has been reported to adhere to intraocular lens (IOL) surfaces following implantation. The aim was to compare Collamer, IPCL, and LENTIS lenses (used as control) in terms of FN distribution and cell adhesion using a small number of explanted Phakic-ICLs. Materials and Methods: Three lens types were analyzed: a Collamer Phakic-ICL (EVO+ Visian ICL), a hydrophilic acrylic IPCL, and a hydrophilic acrylic phakic-IOL (LENTIS). FN distribution and cell adhesion were evaluated across different regions of each lens. An in vitro FN-coating experiment was conducted to assess its effect on cell adhesion. Results: All lenses demonstrated minimal FN deposition and cellular adhesion in the central optical zone. A thin FN film was observed on the haptics of Collamer lenses, while FN adhesion was weaker or absent on IPCL and LENTIS surfaces. Following FN coating, Collamer lenses supported more uniform FN film formation; however, this did not significantly enhance cell adhesion. Conclusions: Collamer, which contains collagen, promotes FN film formation. Although FN film formation was enhanced, the low cell-adhesive properties of HEMA resulted in minimal cell adhesion even with FN presence. This characteristic may contribute to the long-term transparency and biocompatibility observed clinically. In contrast, hydrophilic acrylic materials used in IPCL and LENTIS demonstrated limited FN interaction. These material differences may influence extracellular matrix protein deposition and biocompatibility in clinical settings, warranting further investigation.
Publisher
MDPI AG,MDPI
This website uses cookies to ensure you get the best experience on our website.