MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Performance of dedicated breast positron emission tomography in the detection of small and low-grade breast cancer
Performance of dedicated breast positron emission tomography in the detection of small and low-grade breast cancer
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Performance of dedicated breast positron emission tomography in the detection of small and low-grade breast cancer
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Performance of dedicated breast positron emission tomography in the detection of small and low-grade breast cancer
Performance of dedicated breast positron emission tomography in the detection of small and low-grade breast cancer

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Performance of dedicated breast positron emission tomography in the detection of small and low-grade breast cancer
Performance of dedicated breast positron emission tomography in the detection of small and low-grade breast cancer
Journal Article

Performance of dedicated breast positron emission tomography in the detection of small and low-grade breast cancer

2021
Request Book From Autostore and Choose the Collection Method
Overview
PurposeThis study compares the sensitivity of dedicated breast positron emission tomography (DbPET) and whole body positron emission tomography (WBPET) in detecting invasive breast cancer based on tumor size and biology. Further, we explored the relationship between maximum standardized uptake value (SUVmax) of DbPET and biological features of the tumor.MethodsA total of 639 invasive breast cancer lesions subjected to both DbPET and WBPET before surgery, between January 2016 and May 2019, were included in the study. The sensitivity of DbPET and WBPET in detection and the biology of the tumor according to the clinicopathological features were retrospectively evaluated.ResultsThe overall sensitivity of DbPET was higher than that of WBPET (91.4% vs. 80.3%, p < 0.001). Subcentimetric tumors were significant (80.9% vs. 54.3%, p < 0.001). Regardless of the nuclear grade, DbPET could detect more lesions than WBPET. The SUVmax was positively correlated with tumor size (R = 0.395, p < 0.001) and the nuclear grade (p < 0.001). Luminal A-like breast cancer had significantly lower SUVmax values than the other subtypes (p < 0.001).ConclusionsDbPET is superior to WBPET in the detection of subcentimetric, low-grade breast cancers. Further, by using SUVmax, DbPET can distinguish luminal A-like breast cancer from the other subtypes.