MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Automated measurement of fetal head circumference using 2D ultrasound images
Automated measurement of fetal head circumference using 2D ultrasound images
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Automated measurement of fetal head circumference using 2D ultrasound images
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Automated measurement of fetal head circumference using 2D ultrasound images
Automated measurement of fetal head circumference using 2D ultrasound images

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Automated measurement of fetal head circumference using 2D ultrasound images
Automated measurement of fetal head circumference using 2D ultrasound images
Journal Article

Automated measurement of fetal head circumference using 2D ultrasound images

2018
Request Book From Autostore and Choose the Collection Method
Overview
In this paper we present a computer aided detection (CAD) system for automated measurement of the fetal head circumference (HC) in 2D ultrasound images for all trimesters of the pregnancy. The HC can be used to estimate the gestational age and monitor growth of the fetus. Automated HC assessment could be valuable in developing countries, where there is a severe shortage of trained sonographers. The CAD system consists of two steps: First, Haar-like features were computed from the ultrasound images to train a random forest classifier to locate the fetal skull. Secondly, the HC was extracted using Hough transform, dynamic programming and an ellipse fit. The CAD system was trained on 999 images and validated on an independent test set of 335 images from all trimesters. The test set was manually annotated by an experienced sonographer and a medical researcher. The reference gestational age (GA) was estimated using the crown-rump length measurement (CRL). The mean difference between the reference GA and the GA estimated by the experienced sonographer was 0.8 ± 2.6, -0.0 ± 4.6 and 1.9 ± 11.0 days for the first, second and third trimester, respectively. The mean difference between the reference GA and the GA estimated by the medical researcher was 1.6 ± 2.7, 2.0 ± 4.8 and 3.9 ± 13.7 days. The mean difference between the reference GA and the GA estimated by the CAD system was 0.6 ± 4.3, 0.4 ± 4.7 and 2.5 ± 12.4 days. The results show that the CAD system performs comparable to an experienced sonographer. The presented system shows similar or superior results compared to systems published in literature. This is the first automated system for HC assessment evaluated on a large test set which contained data of all trimesters of the pregnancy.

MBRLCatalogueRelatedBooks