Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
A novel algorithm for differential protection of untransposed transmission line using synchronized measurements
by
Dambhare, SS
, Dahane, AS
2012
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
A novel algorithm for differential protection of untransposed transmission line using synchronized measurements
by
Dambhare, SS
, Dahane, AS
2012
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
A novel algorithm for differential protection of untransposed transmission line using synchronized measurements
Conference Proceeding
A novel algorithm for differential protection of untransposed transmission line using synchronized measurements
2012
Request Book From Autostore
and Choose the Collection Method
Overview
Although there has been a practice of transposition of transmission lines, most of the real life EHV/UHV lines are untransposed. The distance protection of such lines becomes very complicated. With the advent of Global Positioning System (GPS) and Fiber optics technology, current differential protection can be a better choice for such lines. This paper proposes current differential protection scheme for protection of untransposed transmission lines based on equivalent-π line model. The proposed differential relay basically works on difference of currents in series branch (computed) from equivalent-π line model. As the measurements are time synchronized, the performance of relay is immune to line charging current. The analysis has been carried out in phase coordinates. ATP/EMTP programs have been used to simulate system disturbance and algorithm is implemented MATLAB. The result shows the efficacy and robustness of proposed algorithm. (4 pages)
Publisher
The Institution of Engineering & Technology
ISBN
9781849196208, 1849196206
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.