تفاصيل الأصول
MbrlCatalogueTitleDetail
هل ترغب في حجز الكتاب؟
A Pre-Column Derivatization Method for the HPLC-FLD Determination of Dimethyl and Diethyl Amine in Pharmaceuticals
بواسطة
Almpani, Sofia
, Kamaris, Georgios
, Markopoulou, Catherine K.
, Tsami, Maria
, Lotca, Georgiana-Roxana
في
Amino acids
/ Backup software
/ Carcinogens
/ Chromatography
/ Chromatography, High Pressure Liquid - methods
/ Detectors
/ diethylamine and dimethylamine
/ Diethylamines - chemistry
/ Dimethylamines - analysis
/ Dimethylamines - chemistry
/ High performance liquid chromatography
/ HPLC-FLD
/ Investigations
/ Methods
/ NBD-Cl
/ Nitrosoamines
/ Pharmaceutical Preparations - analysis
/ Pharmaceutical Preparations - chemistry
/ Pharmaceuticals
/ Phosphates
/ Phosphoric acid
/ pre-column derivatization
/ Reagents
/ Reproducibility
/ Reproducibility of Results
/ Sensors
/ SPE
/ Spectrometry, Fluorescence - methods
/ Temperature
/ Toxicity
2024
لقد وضعنا الحجز لك!
بالمناسبة ، لماذا لا تستكشف الفعاليات التي يمكنك حضورها عند زيارتك للمكتبة لإستلام كتبك
أنت حاليًا في قائمة الانتظار لالتقاط هذا الكتاب. سيتم إخطارك بمجرد انتهاء دورك في التقاط الكتاب
هل أنت متأكد أنك تريد إزالة الكتاب من الرف؟
A Pre-Column Derivatization Method for the HPLC-FLD Determination of Dimethyl and Diethyl Amine in Pharmaceuticals
بواسطة
Almpani, Sofia
, Kamaris, Georgios
, Markopoulou, Catherine K.
, Tsami, Maria
, Lotca, Georgiana-Roxana
في
Amino acids
/ Backup software
/ Carcinogens
/ Chromatography
/ Chromatography, High Pressure Liquid - methods
/ Detectors
/ diethylamine and dimethylamine
/ Diethylamines - chemistry
/ Dimethylamines - analysis
/ Dimethylamines - chemistry
/ High performance liquid chromatography
/ HPLC-FLD
/ Investigations
/ Methods
/ NBD-Cl
/ Nitrosoamines
/ Pharmaceutical Preparations - analysis
/ Pharmaceutical Preparations - chemistry
/ Pharmaceuticals
/ Phosphates
/ Phosphoric acid
/ pre-column derivatization
/ Reagents
/ Reproducibility
/ Reproducibility of Results
/ Sensors
/ SPE
/ Spectrometry, Fluorescence - methods
/ Temperature
/ Toxicity
2024
وجه الفتاة! هناك خطأ ما.
أثناء محاولة إزالة العنوان من الرف ، حدث خطأ ما :( يرجى إعادة المحاولة لاحقًا!
وجه الفتاة! هناك خطأ ما.
أثناء محاولة إضافة العنوان إلى الرف ، حدث خطأ ما :( يرجى إعادة المحاولة لاحقًا!
هل تريد طلب الكتاب؟
A Pre-Column Derivatization Method for the HPLC-FLD Determination of Dimethyl and Diethyl Amine in Pharmaceuticals
بواسطة
Almpani, Sofia
, Kamaris, Georgios
, Markopoulou, Catherine K.
, Tsami, Maria
, Lotca, Georgiana-Roxana
في
Amino acids
/ Backup software
/ Carcinogens
/ Chromatography
/ Chromatography, High Pressure Liquid - methods
/ Detectors
/ diethylamine and dimethylamine
/ Diethylamines - chemistry
/ Dimethylamines - analysis
/ Dimethylamines - chemistry
/ High performance liquid chromatography
/ HPLC-FLD
/ Investigations
/ Methods
/ NBD-Cl
/ Nitrosoamines
/ Pharmaceutical Preparations - analysis
/ Pharmaceutical Preparations - chemistry
/ Pharmaceuticals
/ Phosphates
/ Phosphoric acid
/ pre-column derivatization
/ Reagents
/ Reproducibility
/ Reproducibility of Results
/ Sensors
/ SPE
/ Spectrometry, Fluorescence - methods
/ Temperature
/ Toxicity
2024
يرجى العلم أن الكتاب الذي طلبته لا يمكن استعارته. إذا كنت ترغب في إستعارة هذا الكتاب ، يمكنك حجز نسخة أخرى
A Pre-Column Derivatization Method for the HPLC-FLD Determination of Dimethyl and Diethyl Amine in Pharmaceuticals
Journal Article
A Pre-Column Derivatization Method for the HPLC-FLD Determination of Dimethyl and Diethyl Amine in Pharmaceuticals
2024
الطلب من المخزن الآلي
واختر طريقة الاستلام
نظرة عامة
In recent years, the detection of nitrosamine precursors has become an important issue for regulatory authorities such as the European Medicines Agency (EMA) and the Food and Drug Administration (FDA). The present study provides a pre-column derivatization method for the analysis of dimethylamine (DMA) and diethylamine (DEA) in pharmaceutical products using HPLC and a fluorescence detector. Appropriate chromatographic parameters, including mobile phase composition (organic solvent, buffer, pH), elution type, flow rate, temperature, and λexcitation/emission, were investigated. Analysis was performed at λexcitation = 450 nm and λemission = 540 nm on a C18 column (at 40 °C) using gradient elution as a mobile phase with Eluent A: Phosphoric Acid Buffer (20 mM, pH = 2.8) and Eluent B: methanol, with a flow of 0.8 mL/min. The method was validated according to ICH specifications in terms of linearity (0.5–10 ng/mL for DMA and 5–100 ng/mL for DEA), specificity, and robustness, as well as repeatability, intermediate precision (%RSD < 2.9), and accuracy (% recovery 98.2–102.0%). The derivatization process was optimized using the “Crossed D-Optimal” experimental design procedure, where one mixture component was cross-correlated with two factors. The stability of the samples was studied over a period of one month. To process the samples (pharmaceuticals), various purification techniques were tried using solid/liquid or liquid/liquid extraction with dichloromethane. Finally, a straightforward solid-phase extraction (SPE, C18) method was chosen prior to derivatization. The method was successfully applied, since the extraction recoveries were >81.6% for DMA (0.5 ppm) and >81.1% for DEA (5 ppm). Based on the results obtained and the available literature, the scientific community seeks, by proposing flexible analytical methods, to delimit the problem of nitrosamines.
الناشر
MDPI AG,MDPI
موضوع
/ Chromatography, High Pressure Liquid - methods
/ diethylamine and dimethylamine
/ High performance liquid chromatography
/ HPLC-FLD
/ Methods
/ NBD-Cl
/ Pharmaceutical Preparations - analysis
/ Pharmaceutical Preparations - chemistry
/ Reagents
/ Sensors
/ SPE
/ Spectrometry, Fluorescence - methods
/ Toxicity
يستخدم هذا الموقع ملفات تعريف الارتباط لضمان حصولك على أفضل تجربة على موقعنا.