Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
1 result(s) for "Śliwiak Dominik"
Sort by:
XEN Gel Stent in the management of primary open-angle glaucoma
PurposeTo assess the efficacy and safety of the XEN Gel Stent in patients with primary open-angle glaucoma.Materials and methodsTwenty eyes of 17 patients (6 males, 11 females) with primary open-angle glaucoma were implanted with XEN Gel Stent. The following data were ascertained in each participant at baseline and at 1, 3, 6, 9 and 12 months following implanting procedure: intraocular pressure, number of anti-glaucoma medications, retinal sensitivity (PS 24/2 w/w), pattern electroretinogram (ISCEV standard), as well as the number of complications.ResultsThe mean intraocular pressure reduction in a 1-year follow-up was 18% (21.56 vs. 17.69 mmHg, p < 0.001). The mean number of anti-glaucoma medications was reduced from 3.2 to 1.6 (p = 0.001). The PERG parameters at baseline and at 12 months postoperatively included a stable amplitude of P50 (2.55 µV vs. 2.65 µV, p = 0.024) and N95 (3.45 µV vs. 3.38 µV, p = ns) waves. The delta N95 and delta P50 amplitudes remained stable over the follow-up period (p = ns). The mean deviation (MD) of PS 24/2 was − 6.54 dB vs. − 8.43 dB, p = ns, whereas the pattern standard deviation (PSD) was 6.18 dB vs. 6.91 dB, p = ns. Transient hypotony within the first postoperative week occurred in 18 eyes (90%), whereas hyphema occurred in two eyes (10%). Needle revision of a filtration bleb was performed in five eyes (25%).ConclusionsThe XEN Gel Stent enables significant reduction in intraocular pressure with very low complication rates. It ensures a stabilization of the retinal function as established with the PERG.