Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
35 result(s) for "Ahn, Seong-Hun"
Sort by:
A cytological observation of the fluid in the primo-nodes and vessels on the surfaces of mammalian internal organs
We report on the preliminary cytological observation of fluid in the primo-nodes and vessels on the surfaces of the internal organs of mammals. With some microsurgical procedures, we observed many cells and microcells that spread out of the nodes on the organ surfaces of rats and rabbits. These cells generally showed the following morphologies: (1) round or oval cells, 10 μm in size, with predominantly little cytoplasm; (2) cells with nuclei that exhibited a collapsed shape; (3) binucleated cells, 20 μm in size; (4) spherical granules, ranging 0.5–2.0 μm in size (primo-microcells); and (5) aggregations of such granules. These findings on the existence of cells with diverse morphologies in the fluid of primo-nodes and vessels could be evidence supporting the hypothesis that the anatomical basis of acupuncture meridians (i.e., primo-vascular system) may be a migration channel for various kind of cells.
Safety recommendations for moxa use based on the concentration of noxious substances produced during commercial indirect moxibustion
BackgroundMoxibustion therapy has been used historically for thousands of years and there are many clinical trials supporting its efficacy and effectiveness for various conditions. Moxa smoke has been a major reason for avoiding moxibustion due to its smell and potential risks to the human body.Methods10 units of commercial indirect moxa (CIM) from six manufacturers (A–F) were burnt in a 2.5×2.5×2.5 m chamber without ventilation, and concentrations of carbon oxides (CO and CO2), nitrogen oxides (NOx), and volatile organic compounds (VOCs) from the indoor air samples were measured.ResultsFor brands A, B, C, D, E, and F, respectively, relative to baseline values, we observed an increase in CO (from 0.002 to 0.007, 0.006, 0.005, 0.006, 0.005, and 0.006 parts per billion (ppb)), NOx (from 0.009 to 0.051, 0.025, 0.015, 0.050, 0.019, and 0.020 ppb), and total VOCs (TVOC; from 48.06 to 288.83, 227.93, 140.82, 223.22, 260.15, and 161.35 μg/m3), while the concentration of CO2 was not elevated. Each CIM brand demonstrated different VOC emission characteristics, which could be divided into three groups. On average, we estimated that 20 units of CIM or 2.41 g moxa floss would need to be combusted in order to exceed the safe levels set by Korean environmental law. This limit is likely to be greater in the case of a larger room or use of ventilation.ConclusionsDespite increased CO/NOx/VOC concentrations, overall levels remained within safe limits. These findings may help clinicians to maintain safe moxibustion treatment conditions to help keep both patients and clinicians safe from the pollutants generated by moxa combustion.
Mechanical Stimulation of the HT7 Acupuncture Point to Reduce Ethanol Self-Administration in Rats
Background. Alcoholism, which is a disabling addiction disorder, is a major public health problem worldwide. The present study was designed to determine whether the application of acupuncture at the Shenmen (HT7) point suppresses voluntary alcohol consumption in addicted rats and whether this suppressive effect is potentiated by the administration of naltrexone. Methods. Rats were initially trained to self-administer a sucrose solution by operating a lever. A mechanical acupuncture instrument (MAI) for objective mechanical stimulation was used on rats whose baseline response had been determined. In addition, the effect of HT7 acupuncture on beta-endorphin concentration and ethanol intake via naltrexone were investigated in different groups. Results. We found that ethanol intake and beta-endorphin level in rats being treated with the MAI at the HT7 point reduced significantly. The treatment of naltrexone at high doses reduced the ethanol intake and low-dose injection of naltrexone in conjunction with the MAI also suppressed ethanol intake. Conclusions. The results of the current study indicate that using the MAI at the HT7 point effectively reduces ethanol consumption in rats. Furthermore, the coadministration of the MAI and a low dose of naltrexone can produce some more potent reducing effect of ethanol intake than can acupuncture alone.
Effects of Intermittent Traction Therapy in an Experimental Spinal Column Model
Traction therapy, which is known to be a treatment method for scoliosis, one of many muscles disease, has been used since Hippocrates introduced it. However, the effects of traction therapy are still not clear. In addition, the meridian sinew theory, which is related to muscle treatment and is mentioned in the book on meridian sinews in the Miraculous Pivot of Huangdi’s Internal Classic, has not been the subject of much study. For these reasons, experimental spinal models were made for this study to observe and analyze the lengths of vertebral interspaces after intermittent traction therapy, which is known to be excellent among muscle treatment methods, with various tensile forces. The results showed that the effects of intermittent traction therapy were unclear and that it might be harmful, especially when the pain was induced by muscle weakness. Because the results of this study on intermittent traction therapy were different from those expected from osteopathy or craniosacral theory, better studies of the subject are necessary.
Evaluating Acupuncture Point and Nonacupuncture Point Stimulation with EEG: A High-Frequency Power Spectrum Analysis
To identify physical and sensory responses to acupuncture point stimulation (APS), nonacupuncture point stimulation (NAPS) and no stimulation (NS), changes in the high-frequency power spectrum before and after stimulation were evaluated with electroencephalography (EEG). A total of 37 healthy subjects received APS at the LI4 point, NAPS, or NS with their eyes closed. Background brain waves were measured before, during, and after stimulation using 8 channels. Changes in the power spectra of gamma waves and high beta waves before, during, and after stimulation were comparatively analyzed. After NAPS, absolute high beta power (AHBP), relative high beta power (RHBP), absolute gamma power (AGP), and relative gamma power (RGP) tended to increase in all channels. But no consistent notable changes were found for APS and NS. NAPS is believed to cause temporary reactions to stress, tension, and sensory responses of the human body, while APS responds stably compared to stimulation of other parts of the body.
Automatic Cephalometric Landmark Identification System Based on the Multi-Stage Convolutional Neural Networks with CBCT Combination Images
This study was designed to develop and verify a fully automated cephalometry landmark identification system, based on multi-stage convolutional neural networks (CNNs) architecture, using a combination dataset. In this research, we trained and tested multi-stage CNNs with 430 lateral and 430 MIP lateral cephalograms synthesized by cone-beam computed tomography (CBCT) to make a combination dataset. Fifteen landmarks were manually and respectively identified by experienced examiner, at the preprocessing phase. The intra-examiner reliability was high (ICC = 0.99) in manual identification. The results of prediction of the system for average mean radial error (MRE) and standard deviation (SD) were 1.03 mm and 1.29 mm, respectively. In conclusion, different types of image data might be the one of factors that affect the prediction accuracy of a fully-automated landmark identification system, based on multi-stage CNNs.
Geometry of anchoring miniscrew in the lateral palate that support a tissue bone borne maxillary expander affects neighboring root damage
Anchoring miniscrews used for a tissue bone borne maxillary expander (C-expander) can fail if they contact tooth roots or perforate the maxillary sinus. Cone beam computed tomography images were reviewed retrospectively to evaluate the geometric factors of miniscrew placement in the palate that contribute to root proximity (RP) and sinus perforation (SP), and to investigate the differences of miniscrew placement depth (PD) and placement angle (PA) among the groups in each variable from 340 anchoring miniscrews on 70 patients whose C-expanders showed sufficient stability after palatal expansion for orthodontic treatment. Two types of miniscrews were used: a self-tapping miniscrew with 1.8 mm-in-diameter, and a self-drilling miniscrew with 1.6 mm-in-diameter. While the self-tapping larger diameter miniscrew influenced root proximity significantly, the screw location and PD affected the rate of sinus perforation. PA was significantly different between the right and left sides of the palate. The results of this study confirmed that root proximity and sinus perforation of anchoring miniscrews in a tissue bone borne palatal expander occurred due to certain risk factors, even when the palates were expanded successfully. Knowledge of these factors can help the clinician place miniscrews with less risk of root proximity or sinus perforation.
Comparing zero-profile and conventional cage and plate in anterior cervical discectomy and fusion using finite-element modeling
Conventional cage and plate (CCP) implants usually used in ACDF surgery, do have limitations such as the development of postoperative dysphagia, adjacent segment degeneration, and soft tissue injury. To reduce the risk of these complications, zero-profile stand-alone cage were developed. We used finite-element modeling to compare the total von Mises stress applied to the bone, disc, endplate, cage and screw when using CCP and ZPSC implants. A 3-dimensional FE (Finite element) analysis was performed to investigate the effects of the CCP implant and ZPSC on the C3 ~ T1 vertebrae. We confirmed that the maximum von Mises stress applied with ZPSC implants was more than 2 times greater in the endplate than that applied with CCP implants. The 3D analysis of the ZPSC model von Mises stress measurements of screw shows areas of higher stress in red. Although using ZPSC implants in ACDF reduces CCP implant-related sequalae such as dysphagia, we have shown that greater von Mises stress is applied to the endplate, and screw when using ZPSC implants. This may explain the higher subsidence rate associated with ZPSC implant use in ACDF. When selecting an implant in ACDF, surgeons should consider patient characteristics and the advantages and disadvantages of each implant type.