Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Series Title
      Series Title
      Clear All
      Series Title
  • Reading Level
      Reading Level
      Clear All
      Reading Level
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Content Type
    • Item Type
    • Is Full-Text Available
    • Subject
    • Publisher
    • Source
    • Donor
    • Language
    • Place of Publication
    • Contributors
    • Location
11,879 result(s) for "Anderson, Michael S"
Sort by:
Development, qualification, and validation of the Filovirus Animal Nonclinical Group anti-Ebola virus glycoprotein immunoglobulin G enzyme-linked immunosorbent assay for human serum samples
The need for an efficacious vaccine against highly pathogenic filoviruses was reinforced by the recent and devastating 2014-2016 outbreak of Ebola virus (EBOV) disease in Guinea, Sierra Leone, and Liberia that resulted in more than 10,000 casualties. Such a vaccine would need to be vetted through a U.S. Food and Drug Administration (FDA) traditional, accelerated, or Animal Rule or similar European Medicines Agency (EMA) regulatory pathway. Under the FDA Animal Rule, vaccine-induced immune responses correlating with survival of non-human primates (NHPs), or another well-characterized animal model, following lethal EBOV challenge will need to be bridged to human immune response distributions in clinical trials. When possible, species-neutral methods are ideal for detection and bridging of these immune responses, such as methods to quantify anti-EBOV glycoprotein (GP) immunoglobulin G (IgG) antibodies. Further, any method that will be used to support advanced clinical and non-clinical trials will most likely require formal validation to assess suitability prior to use. Reported here is the development, qualification, and validation of a Filovirus Animal Nonclinical Group anti-EBOV GP IgG Enzyme-Linked Immunosorbent Assay (FANG anti-EBOV GP IgG ELISA) for testing human serum samples.
Efficacy of ceftazidime in a murine model following a lethal aerosol exposure to Burkholderia pseudomallei
Melioidosis is an endemic disease in numerous tropical regions. Additionally, the bacterium that causes melioidosis, Burkholderia pseudomallei , has potential to be used as a biological weapon. Therefore, development of effective and affordable medical countermeasures to serve regions affected by the disease and to have medical countermeasures available in the event of a bioterrorism attack remains critical. The current study evaluated the efficacy of eight distinct acute phase ceftazidime treatment regimens administered therapeutically in the murine model. At the conclusion of the treatment period, survival rates were significantly greater in several of the treated groups when compared to the control group. Pharmacokinetics of a single dose of ceftazidime were examined at 150 mg/kg, 300 mg/kg, and 600 mg/kg and were compared to an intravenous clinical dose administered at 2000 mg every eight hours. The clinical dose has an estimated 100% f T > 4*MIC which exceeded the highest murine dose of 300 mg/kg every six hours at 87.2% f T > 4*MIC. Based upon survival at the end of the treatment regimen and supplemented by pharmacokinetic modeling, a daily dose of 1200 mg/kg of ceftazidime, administered every 6 h at 300 mg/kg, provides protection in the acute phase of inhalation melioidosis in the murine model.
Method feasibility for cross-species testing, qualification, and validation of the Filovirus Animal Nonclinical Group anti-Ebola virus glycoprotein immunoglobulin G enzyme-linked immunosorbent assay for non-human primate serum samples
An anti-Zaire Ebola virus (EBOV) glycoprotein (GP) immunoglobulin G (IgG) enzyme linked immunosorbent assay (ELISA) was developed to quantify the serum levels of anti-EBOV IgG in human and non-human primate (NHP) serum following vaccination and/or exposure to EBOV. This method was validated for testing human serum samples as previously reported. However, for direct immunobridging comparability between humans and NHPs, additional testing was warranted. First, method feasibility experiments were performed to assess cross-species reactivity and parallelism between human and NHP serum samples. During these preliminary assessments, the goat anti-human IgG secondary antibody conjugate used in the previous human validation was found to be favorably cross-reactive with NHP samples when tested at the same concentrations previously used in the validated assay for human sample testing. Further, NHP serum samples diluted in parallel with human serum when tested side-by-side in the ELISA. A subsequent NHP matrix qualification and partial validation in the anti-GP IgG ELISA were performed based on ICH and FDA guidance, to characterize assay performance for NHP test samples and supplement the previous validation for human sample testing. Based on our assessments, the anti-EBOV GP IgG ELISA method is considered suitable for the intended use of testing with both human and NHP serum samples in the same assay for immunobridging purposes.
Interlaboratory comparison for the Filovirus Animal Nonclinical Group (FANG) anti-Ebola virus glycoprotein immunoglobulin G enzyme-linked immunosorbent assay
The need for an efficacious vaccine against highly pathogenic filoviruses was reinforced by the devastating 2014-2016 outbreak of Ebola virus (EBOV) disease (EVD) in Guinea, Sierra Leone, and Liberia that resulted in over 28,000 cases and over 11,300 deaths. In addition, the 2018-2020 outbreak in the Democratic Republic of the Congo currently has over 3,400 cases and over 2,200 deaths. A fully licensed vaccine and at least one other investigational vaccine are being deployed to combat this EVD outbreak. To support vaccine development and pre-clinical/clinical testing a Filovirus Animal Nonclinical Group (FANG) human anti-EBOV GP IgG ELISA was developed to measure anti-EBOV GP IgG antibodies. This ELISA is currently being used in multiple laboratories. Reported here is a characterization of an interlaboratory statistical analysis of the human anti-EBOV GP IgG ELISA as part of a collaborative study between five participating laboratories. Each laboratory used similar method protocols and reagents to measure anti-EBOV GP IgG levels in human serum samples from a proficiency panel consisting of ten serum samples created by the differential dilution of a serum sample positive for anti-GP IgG antibodies (BMIZAIRE105) with negative serum (BMI529). The total assay variability (inter- and intra-assay variability) %CVs observed at each laboratory ranged from 12.2 to 30.6. Intermediate precision (inter-assay variability) for the laboratory runs ranged from 8.9 to 21.7%CV and repeatability (intra-assay variability) %CVs ranged from 7.2 to 23.7. The estimated slope for the relationship between log.sub.10 (Target Concentration) and the log.sub.10 (Observed Concentration) across all five laboratories was 0.95 with a 90% confidence interval of (0.93, 0.97). Equivalence test results showed that the 90% confidence interval for the ratios for the sample-specific mean concentrations at the five individual labs to the overall laboratory consensus value were within the equivalence bounds of 0.80 to 1.25 for each laboratory and test sample, except for six test samples from Lab D, two samples from Lab B1, and one sample from Lab B2. The mean laboratory concentrations for Lab D were less than those from the other laboratories by 20% on average across the serum samples. The evaluation of the proficiency panel at these laboratories provides a limited assessment of assay precision (intermediate precision, repeatability, and total assay variability), dilutional linearity, and accuracy. This evaluation suggests that the within-laboratory performance of the anti-EBOV GP IgG ELISA as implemented at the five laboratories is consistent with the intended use of the assay based on the acceptance criteria used by laboratories that have validated the assay. However, the assessment of between-laboratory performance revealed lower observed concentrations at Lab D and greater variability in assay results at Lab B1 relative to other laboratories.
Evaluation of strategies to modify Anti-SARS-CoV-2 monoclonal antibodies for optimal functionality as therapeutics
The current global COVID-19 pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has resulted in a public health crisis with more than 168 million cases reported globally and more than 4.5 million deaths at the time of writing. In addition to the direct impact of the disease, the economic impact has been significant as public health measures to contain or reduce the spread have led to country wide lockdowns resulting in near closure of many sectors of the economy. Antibodies are a principal determinant of the humoral immune response to COVID-19 infections and may have the potential to reduce disease and spread of the virus. The development of monoclonal antibodies (mAbs) represents a therapeutic option that can be produced at large quantity and high quality. In the present study, a mAb combination mixture therapy was investigated for its capability to specifically neutralize SARS-CoV-2. We demonstrate that each of the antibodies bind the spike protein and neutralize the virus, preventing it from infecting cells in an in vitro cell-based assay, including multiple viral variants that are currently circulating in the human population. In addition, we investigated the effects of two different mutations in the Fc portion (YTE and LALA) of the antibody on Fc effector function and the ability to alleviate potential antibody-dependent enhancement of disease. These data demonstrate the potential of a combination of two mAbs that target two different epitopes on the SARS-CoV2 spike protein to provide protection against SARS-CoV-2 infection in humans while extending serum half-life and preventing antibody-dependent enhancement of disease.
Assays for the Evaluation of the Immune Response to Marburg and Ebola Sudan Vaccination—Filovirus Animal Nonclinical Group Anti-Marburg Virus Glycoprotein Immunoglobulin G Enzyme-Linked Immunosorbent Assay and a Pseudovirion Neutralization Assay
Since the discovery of the Marburg virus (MARV) in 1967 and Ebola virus (EBOV) in 1976, there have been over 40 reported outbreaks of filovirus disease with case fatality rates greater than 50%. This underscores the need for efficacious vaccines against these highly pathogenic filoviruses. Due to the sporadic and unpredictable nature of filovirus outbreaks, such a vaccine would likely need to be vetted through the U.S. Food and Drug Administration (FDA), following the Animal Rule or similar European Medicines Agency (EMA) regulatory pathway. Under the FDA Animal Rule, vaccine-induced immune responses correlating with survival of non-human primates (NHPs), or another well-characterized animal model, following lethal challenge, will need to be bridged for human immune response distributions in clinical trials. A correlate of protection has not yet been identified for the filovirus disease, but antibodies, specifically anti-glycoprotein (GP) antibodies, are believed to be critical in providing protection against the filovirus disease following vaccination and are thus a strong candidate for a correlate of protection. Thus, species-neutral methods capable of the detection and bridging of these antibody immune responses, such as methods to quantify anti-GP immunoglobulin G (IgG)-binding antibodies and neutralizing antibodies, are needed. Reported here is the development and qualification of two Filovirus Animal Nonclinical Group (FANG) anti-GP IgG Enzyme-Linked Immunosorbent Assays (ELISAs) to quantify anti-MARV and anti-Sudan virus (SUDV) IgG antibodies in human and NHP serum samples, as well as the development of pseudovirion neutralization assays (PsVNAs) to quantify MARV- and SUDV-neutralizing antibodies in human and NHP serum samples.
Ceftobiprole Medocaril Is an Effective Post-Exposure Treatment in the Fischer 344 Rat Model of Pneumonic Tularemia
Francisella tularensis subspecies tularensis is a category-A biothreat agent that can cause lethal tularemia. Ceftobiprole medocaril is being explored as a medical countermeasure for the treatment of pneumonic tularemia. The efficacy of ceftobiprole medocaril against inhalational tularemia was evaluated in the Fischer 344 rat model of infection. The dose was expected to be effective against F. tularensis isolates with ceftobiprole minimum inhibitory concentrations ≤0.5 µg/mL. Animals treated with ceftobiprole medocaril exhibited a 92% survival rate 31 days post-challenge, identical to the survival of levofloxacin-treated rats. By comparison, rats receiving placebo experienced 100% mortality. Terminally collected blood, liver, lung, and spleen samples confirmed disseminated F. tularensis infections in most animals that died prior to completing treatments (placebo animals and a rat treated with ceftobiprole medocaril), although levels of bacteria detected in the placebo samples were significantly elevated compared to the ceftobiprole-medocaril-treated group geometric mean. Furthermore, no evidence of infection was detected in any rat that completed ceftobiprole medocaril or levofloxacin treatment and survived to the end of the post-treatment observation period. Overall, survival rates, body weights, and bacterial burdens consistently demonstrated that treatment with ceftobiprole medocaril is efficacious against otherwise fatal cases of pneumonic tularemia in the rat model.
Effects of Physical Activity on Orthopedic Surgery Resident Quality of Life
Although various factors have been investigated with the goal of improving orthopedic surgery residents' quality of life, there is limited information on the effect of exercise on this population. The primary purpose of this study was to investigate the effects of physical activity on the quality of life of orthopedic surgery residents, with the secondary aim of comparing the differing effects of aerobic and resistance training in this population. Additionally, this study sought to examine the relationship between burnout and quality of life, with the goal of identifying potential associations that may inform targeted interventions to support resident well-being. Sixty-seven orthopedic surgery residents from all postgraduate years were enrolled in this cross-sectional, survey-based quantitative study. Respondents completed the Maslach Burnout Inventory-Human Services Survey for Medical Personnel (MBI-HSS-MP), the International Physical Activity Questionnaire (IPAQ), the World Health Organization Quality of Life questionnaire (WHOQOL-BREF), and the Muscle-Strengthening Exercise Questionnaire (MSEQ) via a secure online platform. Analysis revealed significant negative correlations between the psychological domain of the WHOQOL-BREF and the emotional exhaustion and depersonalization subscales of the MBI-HSS-MP (r = -0.496, < .001; r = -0.267, = .034, respectively). The strongest negative significant correlation was observed between the physical domain of the WHOQOLBREF and emotional exhaustion (r = -0.519, < .001). Physical activity demonstrated a moderate positive correlation with physical quality of life (r = 0.308, = .018) and a strong positive correlation with psychological quality of life (r = 0.450, < .001). The findings suggest that quality of life and burnout are significantly correlated in the orthopedic resident population. Both aerobic and resistance training showed the greatest association with the psychological domain of quality of life, followed by a notable relationship with the physical domain.
Interlaboratory comparison for the Filovirus Animal Nonclinical Group
The need for an efficacious vaccine against highly pathogenic filoviruses was reinforced by the devastating 2014-2016 outbreak of Ebola virus (EBOV) disease (EVD) in Guinea, Sierra Leone, and Liberia that resulted in over 28,000 cases and over 11,300 deaths. In addition, the 2018-2020 outbreak in the Democratic Republic of the Congo currently has over 3,400 cases and over 2,200 deaths. A fully licensed vaccine and at least one other investigational vaccine are being deployed to combat this EVD outbreak. To support vaccine development and pre-clinical/clinical testing a Filovirus Animal Nonclinical Group (FANG) human anti-EBOV GP IgG ELISA was developed to measure anti-EBOV GP IgG antibodies. This ELISA is currently being used in multiple laboratories. Reported here is a characterization of an interlaboratory statistical analysis of the human anti-EBOV GP IgG ELISA as part of a collaborative study between five participating laboratories. Each laboratory used similar method protocols and reagents to measure anti-EBOV GP IgG levels in human serum samples from a proficiency panel consisting of ten serum samples created by the differential dilution of a serum sample positive for anti-GP IgG antibodies (BMIZAIRE105) with negative serum (BMI529). The total assay variability (inter- and intra-assay variability) %CVs observed at each laboratory ranged from 12.2 to 30.6. Intermediate precision (inter-assay variability) for the laboratory runs ranged from 8.9 to 21.7%CV and repeatability (intra-assay variability) %CVs ranged from 7.2 to 23.7. The estimated slope for the relationship between log.sub.10 (Target Concentration) and the log.sub.10 (Observed Concentration) across all five laboratories was 0.95 with a 90% confidence interval of (0.93, 0.97). Equivalence test results showed that the 90% confidence interval for the ratios for the sample-specific mean concentrations at the five individual labs to the overall laboratory consensus value were within the equivalence bounds of 0.80 to 1.25 for each laboratory and test sample, except for six test samples from Lab D, two samples from Lab B1, and one sample from Lab B2. The mean laboratory concentrations for Lab D were less than those from the other laboratories by 20% on average across the serum samples. The evaluation of the proficiency panel at these laboratories provides a limited assessment of assay precision (intermediate precision, repeatability, and total assay variability), dilutional linearity, and accuracy. This evaluation suggests that the within-laboratory performance of the anti-EBOV GP IgG ELISA as implemented at the five laboratories is consistent with the intended use of the assay based on the acceptance criteria used by laboratories that have validated the assay. However, the assessment of between-laboratory performance revealed lower observed concentrations at Lab D and greater variability in assay results at Lab B1 relative to other laboratories.