Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
1 result(s) for "Anic, Zvonimir"
Sort by:
Assessment of Sensor Data from an Air Quality Monitoring Network - The Need for Machine Learning-Based Recalibration and Its Relevance in Health Impact Analysis of Local Pollution Events
Accurate, high-resolution air quality data are crucial for understanding environmental health risks; however, the cost and complexity of maintaining dense, reference-grade monitoring networks remain a significant barrier. This study presents the first city-wide evaluation of next-generation air quality sensors in Zagreb, Croatia, involving 35 sensor locations, one local reference-grade station, and three national reference stations that measure PM[sub.10] and NO[sub.2]. Sensor performance was evaluated against reference data under various meteorological and temporal conditions. To better understand sensor drift and measurement bias, we developed machine learning (ML) calibration models (XGBoost) using spatiotemporal features, ERA5 meteorological variables, and traffic proxy indicators. The models significantly improved accuracy, reducing the root mean squared error (RMSE) by up to 82%, with the greatest improvements observed during pollution peaks. A rolling Root Mean Square Error (RMSE) approach was introduced to track model degradation over time, revealing that recalibration was typically needed within 1–6 months. Our findings demonstrate that, with proper calibration and maintenance, sensor networks can serve as reliable and scalable tools for urban air quality monitoring, capable of supporting both public health assessments and informed decision-making.