Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
12
result(s) for
"Arturo Larco, Jorge L"
Sort by:
Systematic review and meta-analysis of current rates of first pass effect by thrombectomy technique and associations with clinical outcomes
by
Abbasi, Mehdi
,
Kadirvel, Ramanathan
,
Fitzgerald, Seán
in
Aged
,
Bias
,
Brain Ischemia - diagnostic imaging
2021
BackgroundFirst pass effect (FPE) in mechanical thrombectomy is thought to be associated with good clinical outcomes.ObjectiveTo determine FPE rates as a function of thrombectomy technique and to compare clinical outcomes between patients with and without FPE.MethodsIn July 2020, a literature search on FPE (defined as modified Thrombolysis in Cerebral Infarction (TICI) 2c–3 after a single pass) and modified FPE (mFPE, defined as TICI 2b–3 after a single pass) and mechanical thrombectomy for stroke was performed. Using a random-effects meta-analysis, we evaluated the following outcomes for both FPE and mFPE: overall rates, rates by thrombectomy technique, rates of good neurologic outcome (modified Rankin Scale score ≤2 at day 90), mortality, and symptomatic intracerebral hemorrhage (sICH) rate.ResultsSixty-seven studies comprising 16 870 patients were included. Overall rates of FPE and mFPE were 28% and 45%, respectively. Thrombectomy techniques shared similar FPE (p=0.17) and mFPE (p=0.20) rates. Higher odds of good neurologic outcome were found when we compared FPE with non-FPE (56% vs 41%, OR=1.78) and mFPE with non-mFPE (57% vs 44%, OR=1.73). FPE had a lower mortality rate (17% vs 25%, OR=0.62) than non-FPE. FPE and mFPE were not associated with lower sICH rate compared with non-FPE and non-mFPE (4% vs 18%, OR=0.41 for FPE; 5% vs 7%, OR=0.98 for mFPE).ConclusionsOur findings suggest that approximately one-third of patients achieve FPE and around half of patients achieve mFPE, with equivalent results throughout thrombectomy techniques. FPE and mFPE are associated with better clinical outcomes.
Journal Article
Preclinical testing platforms for mechanical thrombectomy in stroke: a review on phantoms, in-vivo animal, and cadaveric models
2021
Preclinical testing platforms have been instrumental in the research and development of thrombectomy devices. However, there is no single model which fully captures the complexity of cerebrovascular anatomy, physiology, and the dynamic artery-clot-device interaction. This article provides a critical review of phantoms, in-vivo animal, and human cadaveric models used for thrombectomy testing and provides insights into the strengths and limitations of each platform. Articles published in the past 10 years that reported thrombectomy testing platforms were identified. Characteristics of each test platform, such as intracranial anatomy, artery tortuosity, vessel friction, flow conditions, device-vessel interaction, and visualization, were captured and benchmarked against human cerebral vessels involved in large-vessel occlusion stroke. Thrombectomy phantoms have been constructed from silicone, direct 3D-printed polymers, and glass. These phantoms represent oversimplified patient-specific cerebrovascular geometry but enable adequate visualization of devices and clots under appropriate flow conditions. They do not realistically mimic the artery-clot interaction. For the animal models, arteries from swine, canines, and rabbits have been reported. These models can reasonably replicate the artery-clot-device interaction and have the unique value of evaluating the safety of thrombectomy devices. However, the vasculature geometries are substantially less complex and flow conditions are different from human cerebral arteries. Cadaveric models are the most accurate vascular representations but with limited access and challenges in reproducibility of testing conditions. Multiple test platforms should be likely used for comprehensive evaluation of thrombectomy devices. Interpretation of the testing results should take into consideration platform-specific limitations.
Journal Article
Transvenous embolization of cerebrospinal fluid-venous fistulas: Independent validation and feasibility of upper-extremity approach and using dual-microcatheter and balloon pressure cooker technique
by
Rozen, Todd D
,
Clendenen, Steven
,
Vibhute, Prasanna
in
Brain
,
Catheters
,
Central Nervous System Vascular Malformations - therapy
2023
BackgroundTransvenous embolization is emerging as a promising treatment for cerebrospinal fluid-venous fistulas (CVF) associated with spontaneous intracranial hypotension (SIH).ObjectiveTo perform an independent validation of the efficacy and safety of the procedure and describe the procedural techniques used at our institution.MethodsA retrospective review was performed including consecutive patients with SIH who had undergone CVF embolization with 3-month clinical and imaging follow-up. Clinical evaluation included the Patient Global Impression of Change (PGIC) Scale and six-item Headache Impact Test (HIT-6). Bern SIH score was used for imaging evaluation on brain MRI. Post-treatment changes in scores were assessed by Wilcoxon signed rank test. Procedural technical details, including use of upper-extremity access and dual-microcatheter pressure cooker technique, were recorded.Results18 patients (13 female, median age 60 years) were included. 17 (94%) procedures were performed with upper-extremity access and 12 (67%) using dual-microcatheter pressure cooker technique. After embolization, 16 (89%) patients reported much or very much improved at follow-up PGIC; median (IQR) HIT-6 score improved from 68 (62–72) to 36 (36–38) and Bern SIH score improved from 8 (6–8) to 3 (1.5–3.5), p values <0.001. Side effects were transient embolization site back pain in 15 (83%) and rebound intracranial hypertension requiring medical management in 9 (50%) patients. HIT-6 and Bern SIH score changes were similar between conventional and pressure cooker techniques (p values >0.05).ConclusionTransvenous embolization is independently validated as a highly effective and safe treatment for CVF and is feasible using upper-extremity venous access. Dual-microcatheter and balloon/coil pressure cooker techniques may be used to optimize distribution of embolic material and potentially, treatment efficacy.
Journal Article
Bioresorbable flow diverters for the treatment of intracranial aneurysms: review of current literature and future directions
by
Kadirvel, Ramanathan
,
Carlson, Kent D
,
Kallmes, David F
in
Absorbable Implants
,
Acids
,
Alloys
2023
The use of flow diverters is a rapidly growing endovascular approach for the treatment of intracranial aneurysms. All FDA-approved flow diverters are composed of nitinol or cobalt-chromium, which will remain in the patient for the duration of their life. Bioresorbable flow diverters have been proposed by several independent investigators as the next generation of flow diverting devices. These devices aim to serve their transient function of occluding and healing the aneurysm prior to being safely resorbed by the body, eliminating complications associated with the permanent presence of conventional flow diverters. Theoretical advantages of bioresorbable flow diverters include (1) reduction in device-induced thrombosis; (2) reduction in chronic inflammation and device-induced stenosis; (3) reduction in side branch occlusion; (4) restoration of physiological vasomotor function; (5) reduction in imaging artifacts; and (6) use in pediatric applications. Advances made in the similar bioresorbable coronary stenting field highlight some of these advantages and demonstrate the feasibility and safety of bioresorbable endovascular devices in the clinic. The current work aims to review the progress of bioresorbable flow diverters, identify opportunities for further investigation, and ultimately stimulate the advancement of this technology.
Journal Article
Aneurysm healing after endovascular treatment in the Helsinki sidewall aneurysm model: a systematic review
by
Kallmes, David F
,
Arturo Larco, Jorge L
,
Kadirvel, Ramanathan
in
Aneurysm
,
Aneurysms
,
Animals
2023
AimsIntracranial aneurysms are treated with a variety of endovascular devices including coils, stents, and flow diverters. The mechanisms by which these devices result in aneurysm occlusion and subsequent healing have been the subject of significant research using various animal models. The murine Helsinki aneurysm model is a sidewall aneurysm created by the end-to-side anastomosis of a donor aortic graft onto the abdominal aorta of a recipient animal. The aim of this systematic review is to assess the efficacy of different endovascular devices for the treatment of the Helsinki model aneurysm.MethodsWe performed a systematic review of Pubmed in accordance with PRISMA guidelines, yielding eight studies detailing the results of endovascular treatment of this preclinical aneurysm model. Studies were included if they provided rates of complete aneurysm occlusion after treatment.ResultsIn these studies, aneurysms were treated with coiling (n=81, 7 studies), stenting (n=67, 3 studies), stent-coiling (n=13, 1 study), and flow diversion (n=49, 2 studies). The results of each individual study are discussed with the goal of providing a measure of the relative efficacy of different endovascular devices for the treatment of this particular model aneurysm. We also pay special attention to insights into the mechanisms underlying aneurysm healing after different forms of endovascular therapy.ConclusionThe data presented here may be useful to investigators attempting to demonstrate superiority of novel endovascular devices relative to previous device iterations using this preclinical model.
Journal Article
Human “live cadaver” neurovascular model for proximal and distal mechanical thrombectomy in stroke
by
Madhani, Sarosh Irfan
,
Abbasi, Mehdi
,
Kadirvel, Ramanathan
in
Brain
,
Cadavers
,
Carotid arteries
2023
BackgroundPreclinical testing platforms that accurately replicate complex human cerebral vasculature are critical to advance neurointerventional knowledge, tools, and techniques. Here, we introduced and validated a human “live cadaveric” head-and-neck neurovascular model optimized for proximal and distal vascular occlusion and recanalization techniques.MethodsHuman cadaveric head-and-neck specimens were cannulated bilaterally in the jugular veins, carotid, and vertebral arteries. Specimens were then coupled with modular glass models of the aorta and extracranial carotid arteries, as well as radial and femoral access ports. Intracranial physiological flow was simulated using a flow-delivery system and blood-mimicking fluid. Baseline anatomy, histological, and mechanical properties of cerebral arteries were compared with those of fresh specimens. Radiopaque clot analogs were embolized to replicate proximal and distal arterial occlusions, followed by thrombectomy. Experienced interventionalists scored the model on different aspects.ResultsCompared with counterpart fresh human arteries, formalin-fixed arteries showed similar mechanical properties, including maximum stretch, increased tensile strength/stiffness, and friction coefficients were also not significantly different. On histology, minimal endothelial damage was noted in arteries after 3 months of light fixation, otherwise the arterial wall maintained the structural integrity. Contrast angiographies showed no micro- or macro-vasculature obstruction. Proximal and distal occlusions created within the middle cerebral arteries were consistently obtained and successfully recanalized. Additionally, interventionists scored the model highly realistic, indicating great similarity to patients’ vasculature.ConclusionsThe human “live cadaveric” neurovascular model accurately replicates the anatomy, mechanics, and hemodynamics of cerebral vasculature and allows the performance of neurointerventional procedures equivalent to those done in patients.
Journal Article
High thrombin-activatable fibrinolysis inhibitor expression in thrombi from stroke patients in elevated estrogen states
by
Larco, Jorge L Arturo
,
Agarwal, Tamanna
,
Ghozy, Sherief
in
Analysis
,
Blood clots
,
Blood coagulation factors
2024
Background
The risk of acute ischemic stroke (AIS) associated with high estrogen states, including pregnant patients and those using oral contraceptives, has been well documented. We described the histological composition of thrombi collected in these cases.
Methods
From a prospective tissue registry (STRIP registry) of thrombi retrieved during mechanical thrombectomy for AIS, we identified 5 patients with high estrogen states: 1 post-partum patient, 1 undergoing hormone replacement therapy and 3 consuming oral contraceptive pills. Five male control patients were randomly chosen matched by age. Immunohistochemistry for CD42b (platelets), von Willebrand factor (vWF), thrombin-activatable fibrinolysis inhibitor (TAFI), fibrinogen and plasminogen activator inhibitor-1 (PAI-1) was performed. Expression was quantified using Orbit Image Software. Student’s t-test was performed as appropriate.
Results
Mean TAFI content for the high estrogen state group was higher than controls (25.6 ± 11.9% versus 9.3 ± 9.0%,
p
= 0.043*). Mean platelet content for the high estrogen state group was lower than controls (41.7 ± 10.6% versus 61.8 ± 12.9%,
p
= 0.029*). No significant difference was found in vWF, fibrinogen and PAI-1 expression. Mean time to recanalize was higher in the high estrogen state group compared to the control group (57.8 ± 27.6 versus 22.6 ± 11.4 min,
p
= 0.0351*). The mean number of passes required was higher in the high estrogen group compared to controls 4.6 versus 1.2,
p
= 0.0261*).
Conclusions
TAFI expression, a powerful driver of thrombosis, was significantly higher in stroke thrombi among patients with high estrogen states compared to controls.
Journal Article
Evaluation of an in vivo preclinical model for human middle meningeal artery embolization using the posterior intercostal artery of the swine
2023
BackgroundEmbolization of the middle meningeal artery (MMA) is a promising minimally invasive technique that is gaining traction in the treatment of chronic subdural hematoma. Unfortunately, the human meninges and associated arteries are significantly larger than those of conventional laboratory animals, making the development of a clinically relevant animal model for testing of embolization agents elusive.ObjectiveTo introduce the posterior intercostal artery (PIA) model in swine and provide anatomical, angiographic, histological, and procedural data to validate its relevance in modeling the human MMA.MethodsIn human cadaveric specimens, 3D angiograms of the internal maxillary arteries (n=6) were obtained and the dura with MMA were harvested and histologically processed. Angiographic and histologic data of the human MMA were compared with the swine PIA (three animals). Then, embolization of the PIA (n=48 arteries) was conducted with liquid embolization agent (Onyx, Medtronic), and angiographic and histological results were assessed acutely (four animals) and after 30 days (two animals).ResultsThe human MMA has equivalent diameter, length, branching pattern, 3D trajectory, and wall structure to those of swine PIAs. Each swine has 12 to 14 PIAs (6–7 per side) suitable for acute or chronic embolization, which can be performed with high fidelity using the same devices, agents, and techniques currently used to embolize the MMA. The arterial wall structure and the acute and chronic histological findings in PIAs after embolization are comparable to those of humans.ConclusionsThis PIA model in swine could be used for research and development; objective benchmarking of agents, devices, and techniques; and in the training of neurointerventionalists.
Journal Article
Correlation of von Willebrand factor and platelets with acute ischemic stroke etiology and revascularization outcome: an immunohistochemical study
by
Patel, Biraj
,
Aghaebrahim, Amin
,
Mendes Pereira, Vitor
in
Atherosclerosis
,
Basic science
,
Blood clots
2023
BackgroundPlatelets and von Willebrand factor (vWF) are key components of acute ischemic stroke (AIS) emboli. We aimed to investigate the CD42b (platelets)/vWF expression, its association with stroke etiology and the impact these components may have on the clinical/procedural parameters.MethodsCD42b/vWF immunostaining was performed on 288 emboli collected as part of the multicenter STRIP Registry. CD42b/VWF expression and distribution were evaluated. Student’s t-test and χ2 test were performed as appropriate.ResultsThe mean CD42b and VWF content in clots was 44.3% and 21.9%, respectively. There was a positive correlation between platelets and vWF (r=0.64, p<0.001**). We found a significantly higher vWF level in the other determined etiology (p=0.016*) and cryptogenic (p=0.049*) groups compared with cardioembolic etiology. No significant difference in CD42b content was found across the etiology subtypes. CD42b/vWF patterns were significantly associated with stroke etiology (p=0.006*). The peripheral pattern was predominant in atherosclerotic clots (36.4%) while the clustering (patchy) pattern was significantly associated with cardioembolic and cryptogenic origin (66.7% and 49.8%, respectively). The clots corresponding to other determined etiology showed mainly a diffuse pattern (28.1%). Two types of platelets were distinguished within the CD42b-positive clusters in all emboli: vWF-positive platelets were observed at the center, surrounded by vWF-negative platelets. Thrombolysis correlated with a high platelet content (p=0.03*). vWF-poor and peripheral CD42b/vWF pattern correlated with first pass effect (p=0.03* and p=0.04*, respectively).ConclusionsThe vWF level and CD42b/vWF distribution pattern in emboli were correlated with AIS etiology and revascularization outcome. Platelet content was associated with response to thrombolysis.
Journal Article
Clot composition and recanalization outcomes in mechanical thrombectomy
2024
BackgroundMechanical thrombectomy (MT) has become standard for large vessel occlusions, but rates of complete recanalization are suboptimal. Previous reports correlated radiographic signs with clot composition and a better response to specific techniques. Therefore, understanding clot composition may allow improved outcomes.MethodsClinical, imaging, and clot data from patients enrolled in the STRIP Registry from September 2016 to September 2020 were analyzed. Samples were fixed in 10% phosphate-buffered formalin and stained with hematoxylin-eosin and Martius Scarlett Blue. Percent composition, richness, and gross appearance were evaluated. Outcome measures included the rate of first-pass effect (FPE, modified Thrombolysis in Cerebral Infarction 2c/3) and the number of passes.ResultsA total of 1430 patients of mean±SD age 68.4±13.5 years (median (IQR) baseline National Institutes of Health Stroke Scale score 17.2 (10.5–23), IV-tPA use 36%, stent-retrievers (SR) 27%, contact aspiration (CA) 27%, combined SR+CA 43%) were included. The median (IQR) number of passes was 1 (1–2). FPE was achieved in 39.3% of the cases. There was no association between percent histological composition or clot richness and FPE in the overall population. However, the combined technique resulted in lower FPE rates for red blood cell (RBC)-rich (P<0.0001), platelet-rich (P=0.003), and mixed (P<0.0001) clots. Fibrin-rich and platelet-rich clots required a higher number of passes than RBC-rich and mixed clots (median 2 and 1.5 vs 1, respectively; P=0.02). CA showed a trend towards a higher number of passes with fibrin-rich clots (2 vs 1; P=0.12). By gross appearance, mixed/heterogeneous clots had lower FPE rates than red and white clots.ConclusionsDespite the lack of correlation between clot histology and FPE, our study adds to the growing evidence supporting the notion that clot composition influences recanalization treatment strategy outcomes.
Journal Article