Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
13 result(s) for "Badian, Reza A"
Sort by:
Seasonal variations in presenting symptoms and signs of dry eye disease in Norway
The study investigated the seasonal variations of presenting symptoms and signs of dry eye disease (DED) in Norway. 652 consecutive DED patients examined between August 2012 and May 2015 in Oslo, Norway, were included. Presenting symptoms and signs were related to the season according to when each patient was examined. Weather report data from the examination day were compared with the presenting symptoms and signs. Oslo's mean seasonal temperatures during spring, summer, fall, and winter were 6.4 °C, 15.6 °C, 9.3 °C, and − 2.1 °C, respectively. Dry eye severity level and self-reported symptoms measured by the Ocular surface disease index questionnaire did not differ between seasons. Schirmer I was lower during summer than in other seasons (P < 0.01). The percentage of patients with a pathological tear meniscus height (< 0.2 mm) was higher during fall (P < 0.01) and lower during winter (P < 0.05) compared to the other seasons. Signs and symptoms of DED generally did not correlate with weather report data, although intraocular pressure was weakly associated with mean daily air temperature (r = − 0.22; P < 0.001). Neither dry eye severity level nor dry eye symptoms differ between seasons in Oslo, Norway. However, some parameters for assessing DED show seasonal variations (Schirmer I and tear meniscus height), which are essential to consider when examining patients with DED.
Meibomian gland dysfunction is highly prevalent among first-time visitors at a Norwegian dry eye specialist clinic
To investigate the prevalence of meibomian gland dysfunction (MGD) in patients presenting with subjective dry eye-related symptoms at their first-time consultation in a Norwegian specialized ocular surface clinic. Additionally, to explore the accuracy of the ocular surface disease index score (OSDI) as an extensively applied tool to assess the severity of dry eye symptoms and MGD diagnosis. Patients with subjective dry eye-related complaints (n = 900) attending the clinic for the first time, from 2012 to 2016, were included in the study. At the baseline, patients completed the OSDI questionnaire. Subsequently, objective clinical tests, including fluorescein break-up time (FBUT), Schirmer-I test, ocular surface staining (OSS), and meibomian gland function assessment using gland expressibility and meibum quality were performed. The association between MGD and its severity in relation to symptom severity defined by OSDI-score was examined. MGD was found in 93.8% of the study group. MGD prevalence was not significantly different between groups based on age (p = 0.302) or sex (p = 0.079). There was a significant association between severity of MGD and dry eye-related symptoms (p = 0.014). OSS was significantly higher in patients with severe symptoms (p = 0.031). Sensitivity and specificity of positive symptom-score (OSDI ≥ 13) for disclosing MGD were 85.5% and 30.4%, respectively. MGD was highly prevalent, not associated with age and sex. OSDI ≥ 13 had high sensitivity and high positive predictive value (PPV), but low specificity and negative predictive value (NPV) for disclosing MGD. This underscores the importance of meibomian gland assessment in patients with dry eye-related symptoms.
TheraPearl Eye Mask and Blephasteam for the treatment of meibomian gland dysfunction: a randomized, comparative clinical trial
Meibomian gland dysfunction (MGD) is the most common cause of dry eye disease (DED). In this study, we aimed to compare the effects of eyelid warming treatment using either TheraPearl Eye Mask (Bausch & Lomb Inc., New York, USA) or Blephasteam (Spectrum Thea Pharmaceuticals LTD, Macclesfield, UK) in a Norwegian population with mild to moderate MGD-related DED. An open label, randomized comparative trial with seventy patients (49 females, 21 males; mean age 53.6 years). Patients were randomly assigned to treatment with Blephasteam (n = 37) or TheraPearl (n = 33). All received a hyaluronic acid based artificial tear substitute (Hylo-Comod, Ursapharm, Saarbrücken, Germany). Patients were examined at baseline, and at three and six months initiation of treatment. Treatment efficacy was primarily evaluated by fluorescein breakup time (FBUT) and Ocular Surface Disease Index (OSDI) scores. Other outcome measures included ocular surface staining (OSS), Schirmer’s test, and meibomian quality and expressibility. Baseline parameter values did not differ between the groups. After six months of treatment, Blephasteam improved FBUT by 3.9 s (p < 0.01) and OSDI by 13.7 (p < 0.01), TheraPearl improved FBUT by 2.6 s (p < 0.01) and OSDI by 12.6 (p < 0.01). No difference between treatments was detected at 6 months (p = 0.11 for FBUT and p = 0.71 for OSDI), nor were there differences in the other tested parameters between the treatment groups. Blephasteam and TheraPearl are equally effective in treating mild to moderate MGD in a Norwegian population after 6-months of treatment. Clinicaltrials.gov ID: NCT03318874; Protocol ID: 2014/1983; First registration: 24/10/2017.
Comparison of non-invasive and fluorescein tear film break-up time in a 65-year-old Norwegian population: a cross-sectional study
ObjectivesMeasurement of tear film stability is central in dry eye disease (DED) diagnosis. In this study, we aimed to compare the performance of two methods of tear film stability measurement: non-invasive tear break-up time (NIBUT) and fluorescein tear film break-up time (FTBUT).DesignCross-sectional study.Setting and participantsThe study involved 132 subjects of 65-year-old inhabitants of the Oslo region who were not seeking ophthalmic care.InterventionsThe participants underwent a battery of DED tests, including NIBUT measured on Oculus Keratograph 5M and a traditional method using fluorescein drops (FTBUT). Oculus Keratograph 5M measures two types of NIBUT:; appearance time of the first dry spot (NIBUTFirst) and average NIBUTAvg.Results74 participants (56%) were female and 58 were male (44%). Subjects presented with varying degrees of DED signs and symptoms. Mean values of NIBUTFirst and FTBUT from all the participants were significantly different (6.2±4.9 s vs 8.6±6.2 s, p<0.0001). There was also a significant difference between NIBUTFirst and NIBUTAvg values (6.2±4.9 s vs 8.3±5.5 s, p<0.0001). In contrast, no difference was observed between FTBUT and NIBUTAvg values (8.6±6.2 s vs 8.3±5.5 s, p=0.655). The receiver operating characteristic curve analysis was performed to compare NIBUT and FTBUT in regards to other clinical tests (Ocular Surface Disease Index, ocular surface staining, blink interval, eye redness, corneal sensitivity, lid debris, Schirmer I test, tear osmolarity, meibum quality, meibum expressibility, lid hyperemia, tear meniscus height,. irregular lid margin, conjunctival hyperaemia, margin telangiectasia, lipid layer and meibomian gland drop-out). While FTBUT demonstrated results with area under the curve>0.6, neither NIBUTFirst nor NIBUTAvg showed significant results.ConclusionNIBUTFirst was shorter than FTBUT. Low correlation between NIBUT and FTBUT indicates that these diagnostic tests are not interchangeable. Other DED tests had correlation, though low, while NIBUT did not demonstrate correlation.
The relationship between ocular and oral dryness in a cohort from the 65-year-old population in Norway
In the present study, the relationship between dry eyes and dry mouth was explored in 150 65-year-old subjects randomly selected from the general population in Oslo, Norway. The number of drugs, including xerogenic drugs, and current and previous systemic diseases were recorded. Ocular parameters recorded were the McMonnies Dry Eye Questionnaire, the Ocular Surface Disease Index, the Schirmer I Test, tear film break-up time and ocular surface staining. The oral parameters were xerostomia frequency, Summated Xerostomia Inventory, Clinical Oral Dryness Score, and unstimulated and stimulated whole saliva. The participants with current or previous systemic diseases had significantly more ocular and oral symptoms and significantly more oral clinical findings than the participants without a history of disease. Moreover, correlation and factor analyses demonstrated an association between subjective ocular and oral parameters. A significant correlation between the total number of drugs and the presence of ocular and oral symptoms was also noted. When the participants were categorized based on their ocular symptoms, poorer values were found for the oral parameters among the participants more troubled with dry eyes. The results in the present study call for increased awareness and an interdisciplinary approach in matters related to dry eyes and dry mouth.
Alterations in meibomian glands in patients treated with intensity-modulated radiotherapy for head and neck cancer
Patients undergoing intensity-modulated radiotherapy (IMRT) for head and neck cancer may have increased incidence of dry eye disease and the exact mechanism is unclear. The present study aims to assess tear film and meibomian gland (MG) features in patients who received IMRT for head and neck cancer not involving the orbital area. Twenty-seven patients (64.7 ± 9.8 years) and 30 age-matched controls (61.4 ± 11.0 years) underwent a comprehensive dry eye work-up. Compared to the control group, the patients had more lid margin abnormalities, and worse meibum quality. The MG loss, calculated as (tarsal area-MG area)/tarsal area, was higher in the patient group in both the upper (53.0 ± 12.0% vs. 35.1 ± 10.3%, p < 0.001) and lower lids (69.5 ± 12.6% vs. 48.5 ± 12.5%, p < 0.001). In the patient group, more MG loss in the lower lids correlated with worse meibum quality (r = 0.445, p = 0.029). In contrast, there was no significant difference in aqueous tear production level, measured with Schirmer test. Patients treated with IMRT for head and neck cancer seemed to have comparable lacrimal gland function to the controls despite more dry eye symptoms. However, the patients had MG functional and morphological changes, which may present a higher risk for developing dry eye disease.
Wide-field mosaics of the corneal subbasal nerve plexus in Parkinson’s disease using in vivo confocal microscopy
In vivo confocal microscopy (IVCM) is a non-invasive imaging technique facilitating real-time acquisition of images from the live cornea and its layers with high resolution (1–2 µm) and high magnification (600 to 800-fold). IVCM is extensively used to examine the cornea at a cellular level, including the subbasal nerve plexus (SBNP). IVCM of the cornea has thus gained intense interest for probing ophthalmic and systemic diseases affecting peripheral nerves. One of the main drawbacks, however, is the small field of view of IVCM, preventing an overview of SBNP architecture and necessitating subjective image sampling of small areas of the SBNP for analysis. Here, we provide a high-quality dataset of the corneal SBNP reconstructed by automated mosaicking, with an average mosaic image size corresponding to 48 individual IVCM fields of view. The mosaic dataset represents a group of 42 individuals with Parkinson’s disease (PD) with and without concurrent restless leg syndrome. Additionally, mosaics from a control group (n = 13) without PD are also provided, along with clinical data for all included participants. Measurement(s) Prominent corneal nerve fibers • Dendritic Cell Technology Type(s) confocal microscopy Factor Type(s) disease status • comorbidity Sample Characteristic - Organism Homo sapiens Machine-accessible metadata file describing the reported data: https://doi.org/10.6084/m9.figshare.16691452
Tissue Harvesting Site and Culture Medium Affect Attachment, Growth, and Phenotype of Ex Vivo Expanded Oral Mucosal Epithelial Cells
Transplantation of cultured oral mucosal epithelial cells (OMECs) is a promising treatment strategy for limbal stem cell deficiency. In order to improve the culture method, we investigated the effects of four culture media and tissue harvesting sites on explant attachment, growth, and phenotype of OMECs cultured from Sprague-Dawley rats. Neither choice of media or harvesting site impacted the ability of the explants to attach to the culture well. Dulbecco’s modified Eagle’s medium/Ham’s F12 (DMEM) and Roswell Park Memorial Institute 1640 medium (RPMI) supported the largest cellular outgrowth. Fold outgrowth was superior from LL explants compared to explants from the buccal mucosa (BM), HP, and transition zone of the lower lip (TZ) after six-day culture. Putative stem cell markers were detected in cultures grown in DMEM and RPMI. In DMEM, cells from TZ showed higher colony-forming efficiency than LL, BM, and HP. In contrast to RPMI, DMEM both expressed the putative stem cell marker Bmi-1 and yielded cell colonies. Our data suggest that OMECs from LL and TZ cultured in DMEM give rise to undifferentiated cells with high growth capacity, and hence are the most promising for treatment of limbal stem cell deficiency.
Parkinson’s disease with restless legs syndrome—an in vivo corneal confocal microscopy study
Small fiber neuropathy (SFN) has been suggested as a trigger of restless legs syndrome (RLS). An increased prevalence of peripheral neuropathy has been demonstrated in Parkinson’s disease (PD). We aimed to investigate, in a cross-sectional manner, whether SFN is overrepresented in PD patients with concurrent RLS relative to PD patients without RLS, using in vivo corneal confocal microscopy (IVCCM) and quantitative sensory testing (QST) as part of small fiber assessment. Study participants comprised of age- and sex-matched PD patients with (n = 21) and without RLS (n = 21), and controls (n = 13). Diagnosis of RLS was consolidated with the sensory suggested immobilization test. Assessments included nerve conduction studies (NCS), Utah Early Neuropathy Scale (UENS), QST, and IVCCM, with automated determination of corneal nerve fiber length (CNFL) and branch density (CNBD) from wide-area mosaics of the subbasal nerve plexus. Plasma neurofilament light (p-NfL) was determined as a measure of axonal degeneration. No significant differences were found between groups when comparing CNFL (p = 0.81), CNBD (p = 0.92), NCS (p = 0.82), and QST (minimum p = 0.54). UENS scores, however, differed significantly (p = 0.001), with post-hoc pairwise testing revealing higher scores in both PD groups relative to controls (p = 0.018 and p = 0.001). Analysis of all PD patients (n = 42) revealed a correlation between the duration of l-dopa therapy and CNBD (ρ = −0.36, p = 0.022), and p-NfL correlated with UENS (ρ = 0.35, p = 0.026) and NCS (ρ = −0.51, p = 0.001). Small and large fiber neuropathy do not appear to be associated with RLS in PD. Whether peripheral small and/or large fiber pathology associates with central neurodegeneration in PD merits further longitudinal studies.
Region of interest and directional analysis of subbasal nerves in wide-area corneal nerve plexus mosaics in type 2 diabetes mellitus
In vivo confocal microscopy (IVCM) imaging of the corneal subbasal nerve plexus (SBNP) is a clinical imaging modality gaining popularity for the diagnosis and follow-up of corneal neuropathy in various conditions such as diabetes mellitus. There remain, however, major limitations to the method, hindering its widespread clinical use. Finding the same exact area of the central cornea to standardize image acquisition is difficult without a reference point. Alternatively, creating wide-area mosaics of the SBNP is resource-intensive and has not yet been developed for routine clinical use. Here, we investigated whether IVCM analysis of the corneal SBNP in a predetermined, anatomically standardized region of interest (ROI) could be applied as an equivalent substitution for wide-area SBNP mosaic generation and analysis. Furthermore, we investigated nerve patterns outside the central corneal region for a possible relationship to type 2 diabetes mellitus status using a publicly available dataset. We found that corneal nerve fibre length density (CNFL) based on the ROI underestimated the mosaic-based CNFL by an average of 34% in 90% of cases (150 eyes), and did not exhibit a significant reduction with diabetes, as seen in the full SBNP. Outside the central cornea, nerve orientation differed depending on the anatomic region (left, central or right superior plexus, P < 0.001). Moreover, in long-term type 2 diabetes mellitus (≥ 10 years, 28 subjects), nerve density in the left superior sector of the SBNP was decreased (P < 0.001) while that in the central superior SBNP increased (P = 0.01) relative to 35 age-matched healthy subjects with normal glucose tolerance. These results indicate that subbasal nerve degeneration in type 2 diabetes mellitus can vary according to anatomic location, and regions with potential diagnostic value outside the central SBNP may warrant further investigation.