Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
4
result(s) for
"Ban, Kyoko"
Sort by:
Clinical Features of Acute Flaccid Myelitis Temporally Associated With an Enterovirus D68 Outbreak: Results of a Nationwide Survey of Acute Flaccid Paralysis in Japan, August–December 2015
by
Hata, Atsuko
,
Oba, Chizu
,
Sakajiri, Kenichi
in
Acute Disease - epidemiology
,
Adults
,
and Commentaries
2018
Acute flaccid myelitis (AFM) is an acute flaccid paralysis syndrome with spinal motor neuron involvement of unknown etiology. We investigated the characteristics and prognostic factors of AFM clusters coincident with an enterovirus D68 (EV-D68) outbreak in Japan during autumn 2015.
An AFM case series study was conducted following a nationwide survey from August to December 2015. Radiographic and neurophysiologic data were subjected to centralized review, and virology studies were conducted for available specimens.
Fifty-nine AFM cases (58 definite, 1 probable) were identified, including 55 children and 4 adults (median age, 4.4 years). The AFM epidemic curve showed strong temporal correlation with EV-D68 detection from pathogen surveillance, but not with other pathogens. EV-D68 was detected in 9 patients: 5 in nasopharyngeal, 2 in stool, 1 in cerebrospinal fluid (adult case), and 1 in tracheal aspiration, nasopharyngeal, and serum samples (a pediatric case with preceding steroid usage). Cases exhibited heterogeneous paralysis patterns from 1- to 4-limb involvement, but all definite cases had longitudinal spinal gray matter lesions on magnetic resonance imaging (median, 20 spinal segments). Cerebrospinal fluid pleocytosis was observed in 50 of 59 cases (85%), and 8 of 29 (28%) were positive for antiganglioside antibodies, as frequently observed in Guillain-Barré syndrome. Fifty-two patients showed variable residual weakness at follow-up. Good prognostic factors included a pretreatment manual muscle strength test unit score >3, normal F-wave persistence, and EV-D68-negative status.
EV-D68 may be one of the causative agents for AFM, while host susceptibility factors such as immune response could contribute to AFM development.
Journal Article
Allopurinol challenge tests performed before and after living‐related donor liver transplantation in citrullinaemia
by
Wada, Y.
,
Kidouchi, K.
,
Ban, K.
in
Allopurinol
,
Antimetabolites
,
Biological and medical sciences
2003
We performed allopurinol challenge tests to evaluate the metabolic state of a citrullinaemic patient who received a living‐relative donor liver transplant. Before transplantation, large amounts of orotic acid and orotidine were excreted during the challenge test. Following transplantation, excretion of these compounds in response to allopurinol was normalised. The challenge test was a safe and useful method to evaluate the metabolic state of the patient.
Journal Article
Clinical evaluation of a newly developed automated hemodialysis system as a clinical trial
by
Takuya Ban
,
Satoshi Funakoshi
,
Tetsunosuke Kunitomo
in
Automated system
,
Automation
,
Blood pressure
2018
Background
To cope with the increasing number of patients on long-term hemodialysis (HD), especially those with diabetic nephropathy, we designed a fully automated HD system to decrease staff workload and hence human errors related to HD treatment. In this study, we evaluated this new system as a clinical trial.
Methods
Based on a dialysis machine combined with a central dialysate delivery system (CDDS), the new system is characterized by the use of back ultrafiltrated dialysate (BUD) as a substitute fluid for priming, bonus shot and blood return, and the attachment of double endotoxin retentive filters (ETRFs).
Results
The subjects comprised 61 patients from five HD facilities enrolled in a randomized, open-labeled crossover study after giving written informed consent.
A total of 348 HD treatments for 58 of the 61 patients were studied under a protocol designed in accordance with good clinical practice (GCP) guidelines and approved by the respective institutional review boards. No severe adverse effects were observed with either the test or control systems. The incidence of clinical events, including blood pressure decline, residual blood, and error in fluid removal, was not statistically significant in either group. Neither endotoxins nor bacteria were detected in the dialysate passing through the double filters.
Conclusions
This study confirmed the safety and effectiveness of an automated HD system based on CDDS.
(This Clinical Trial No. is 21500BZZ00045000)
Journal Article