Eye movement characteristics and visual fatigue assessment of virtual reality games with different interaction modes
2023
This study aimed to investigate the eye movement characteristics and visual fatigue of virtual reality games with different interaction modes. Eye movement data were recorded using the built-in eye tracker of the VR device and eye movement parameters were calculated from the recorded raw data. The Visual Fatigue Scales and Simulator Sickness Questionnaire were used to subjectively assess visual fatigue and overall discomfort of the VR experience. Sixteen male and 17 female students were recruited for this study. Results showed that both the primary and 360 mode of VR could cause visual fatigue after 30 min of gameplay, with significant differences observed in eye movement behavior between the two modes. The primary mode was more likely to cause visual fatigue, as shown by objective measurements of blinking and pupil diameter. Fixation and saccade parameters also showed significant differences between the two modes, possibly due to the different interaction modes employed in the 360 mode. Further research is required to examine the effects of different content and interactive modes of VR on visual fatigue, as well as to develop more objective measures for assessing it.
Journal Article
Axial Length Measurement Failure Rates with the IOLMaster and Lenstar LS 900 in Eyes with Cataract
2015
To evaluate axial length (AL) measurement failure rate with the IOLMaster (Carl Zeiss AG, Germany) and Lenstar LS 900 (Haag-Streit AG, Switzerland) in eyes with cataract.
Two hundred and ninety-six eyes of 170 patients with cataract were enrolled. Cataract type and severity were graded using the Lens Opacities Classification System III (LOCS III) and AL measurements were attempted with IOLMaster (version 5.4) and Lenstar LS 900 (version 1.1). Chi-squared analysis was used to assess if the difference in AL measurement acquisition rate was statistically significant between the two devices. The association of the different cataract types and severity with the AL measurement acquisition rate was evaluated with logistic regression analysis.
AL measurements were obtained in 184 eyes (62.16%) using the IOLMaster and 191 eyes (64.53%) using the Lenstar, which corresponds to a failure rate of 37.84% and 35.47% respectively. Chi-square analysis indicated no significant difference between the Lenstar and IOLMaster for AL measurement failure rate (x2 = 0.356, P = 0.550). Logistic regression analysis indicated no association between acquisition rates and cortical or nuclear cataracts with either device. There was a statistically significant association between acquisition rates and increasing severity of posterior subcapsular cataracts with the IOLMaster (β = -1.491, P<0.001) and Lenstar LS 900 (β = -1.507, P<0.001).
The IOLMaster and Lenstar LS 900 have similar AL measurement failure rates (35-38%) for Chinese public hospital cataract patients. Increasing severity of posterior subcapsular cataracts was problematic for both devices.
Journal Article
Assessment of age-related change of the ocular support system
by
Makarem, Ahmed
,
Elsheikh, Ahmed
,
Abass, Ahmed
in
Bioengineering and Biotechnology
,
Boundary conditions
,
Cornea
2023
To estimate the material stiffness of the orbital soft tissue in human orbits using an inverse numerical analysis approach, which could be used in future studies to understand the behaviour under dynamic, non-contact tonometry or simulate various ophthalmological conditions. Clinical data were obtained for the left eye of 185 Chinese participants subjected to a complete ophthalmic examination, including tests by the Corvis ST and Pentacam. 185 numerical models of the eye globes were built with idealised geometry of the sclera while considering the corneal tomography measured by the Pentacam. The models were extended to include representations of the orbital soft tissue (OST), which were given idealised geometry. The movement of the whole eye in response to an air-puff directed at the central cornea was examined and used in an inverse analysis process to estimate the biomechanical stiffness parameters of the OST. The results indicated a weak correlation of E t with the progression of age, regardless of the stress at which E t was calculated. However, there was evidence of significant differences in E t between some of the age groups. There was statistical evidence of significant differences between E t in the age range 20< years < 43 relative to E t in OST with age ranges 43< years < 63 ( p = 0.022) and 63< years < 91 ( p = 0.011). In contrast, E t in OST with age ranges 43< years < 63 and 63< years < 91 were not significantly different ( p = 0.863). The optimised mechanical properties of the OST were found to be almost four times stiffer than properties of fatty tissue of previous experimental work. This study consolidated previous findings of the role of extraocular muscles on the ocular suppor system. In addition, the rotation of the globe during corvis loading is suggested to be of posterior components of the globe and shall be further investigated.
Journal Article
Biomechanical Effects of tPRK, FS-LASIK, and SMILE on the Cornea
2022
Purpose: The objective of this study is to evaluate the in vivo corneal biomechanical response to three laser refractive surgeries. Methods: Two hundred and twenty-seven patients who submitted to transepithelial photorefractive keratectomy (tPRK), femtosecond laser-assisted in-situ keratomileusis (FS-LASIK), or small-incision lenticule extraction (SMILE) were included in this study. All cases were examined with the Corvis ST preoperatively (up to 3 months) and postoperatively at 1, 3, and 6 months, and the differences in the main device parameters were assessed. The three groups were matched in age, gender ratio, corneal thickness, refractive error corrections, optical zone diameter, and intraocular pressure. They were also matched in the preoperative biomechanical metrics provided by the Corvis ST including stiffness parameter at first applanation (SP-A1), integrated inverse radius (IIR), deformation amplitude (DA), and deformation amplitude 2 mm away from apex and the apical deformation (DARatio2mm). Results: The results demonstrated a significant decrease post-operation in SP-A1 and significant increases in IIR, DA, and DARatio2mm ( p < 0.05), all of which indicated reductions in overall corneal stiffness. Inter-procedure comparisons provided evidence that the smallest overall stiffness reduction was in the tPRK group, followed by the SMILE, and then the FS-LASIK group ( p < 0.05). These results remained valid after correction for the change in CCT between pre and 6 months post-operation and for the percentage tissue altered. In all three surgery groups, higher degrees of refractive correction resulted in larger overall stiffness losses based on most of the biomechanical metrics. Conclusion: The corneal biomechanical response to the three surgery procedures varied significantly. With similar corneal thickness loss, the reductions in overall corneal stiffness were the highest in FS-LASIK and the lowest in tPRK.
Journal Article
Corneal higher-order aberrations and their relationship with choroid in myopic patients
by
Li, Fenfen
,
Bao, Fangjun
,
Ye, Yufeng
in
Adult
,
Advancements in myopia
,
Axial Length, Eye - diagnostic imaging
2024
Background
To investigate corneal higher-order aberrations (HOAs) and choroidal characteristics in myopic individuals and explore the association between HOAs and choroidal parameters.
Methods
Myopic participants were categorized into three groups based on axial lengths (ALs). We compared corneal HOAs, including spherical (Z
4
0
), comatic (Z
3
− 1
and Z
3
1
), and trefoil (Z
3
− 3
and Z
3
3
) aberrations, as well as choroidal vascularity index (CVI) and choroidal thickness (CT). Linear regression analysis was used to assess the relationships among corneal HOAs, CVI, CT, spherical equivalent, and AL.
Results
Groups 1, 2, and 3 included 105, 98, and 118 eyes, respectively. Group 3 exhibited lower spherical HOA root mean square and Z
4
0
values than group 1(
p
< 0.05). Group 1 showed lower Z
3
1
levels than other groups (
p
< 0.001). Groups 1 and 2 had higher mean, central, and I2 vertical CVIs than group 3 (
p
< 0.05). Group 1 had a larger vertical S1 CVI than group 3 (
p
< 0.05). Group 3 had smaller horizontal CVI values in all regions except N2 (
p
< 0.05). Both the mean and CT in all regions decreased as AL increased (
p
< 0.001). The comatic (Z
3
1
) and trefoil (Z
3
3
) components were predictors of mean horizontal CVI, and the comatic (Z
3
1
) component was correlated with both mean vertical and horizontal CT.
Conclusion
Longer AL myopic patients exhibited lower absolute values of spherical aberration and horizontal coma. Alterations in choroid in myopic patients correlated with corneal HOAs. Our results suggest a potential connection between the optical quality and ocular perfusion in myopia.
Journal Article
Effect of Intraorbital Mechanical Compression on Retinal Microvascular Perfusion in Quiescent Thyroid-Associated Ophthalmopathy Based on Ocular Biomechanics Measured by Corvis ST
by
Qian, Zhenbin
,
Wang, Mengdi
,
Bao, Fangjun
in
Biomechanical phenomena
,
Graves ophthalmopathy
,
Internal Medicine
2024
Introduction
To analyze the correlation between orbital compliance and retinal vessel density (VD) based on dynamic Scheimpflug analyzer (Corvis ST) and optical coherence tomographic angiography (OCT-A).
Methods
In this prospective observational study, 65 eyes of 44 patients with thyroid-associated ophthalmopathy (TAO) in quiescent stage were included (15 males and 29 females). The whole eye movement (WEM) was detected by Corvis ST. The superficial capillary plexus VD (SCP-VD) and deep capillary plexus VD (DCP-VD) were obtained by scanning the 3 × 3 mm area around the fovea using OCT-A, while the peripapillary vessel density (ppVD) was obtained by scanning the 4.5 × 4.5 mm area around the optic disk. Covariances including biomechanically corrected intraocular pressure (bIOP), axial length, age and gender were adjusted during data analysis.
Results
The mean WEM of the participants was 0.235 ± 0.066 mm. The mean SCP-VD and DCP-VD in whole image were 46.20% ± 3.77% and 50.51% ± 3.96%; the mean whole pp-VD was 49.75% ± 2.01%. WEM was positively correlated with SCP-VD (
r
= 0.327,
p
= 0.01) and the whole pp-VD (
r
= 0.394,
p
< 0.01) after adjusting by gender, axial length (AL), age and bIOP, but it was not significantly correlated with DCP-VD (
r
= 0.072
p
= 0.581).
Conclusion
Increase in orbital pressure might reduce retinal microvascular perfusion. Our data suggest orbital mechanical compression may be an important cause of retinal VD changes in quiescent patients with TAO.
Journal Article
Assessment of Cataract Surgery Outcome Using the Modified Catquest Short-Form Instrument in China
by
Khadka, Jyoti
,
Gao, Rongrong
,
Huang, Jinhai
in
Activities of Daily Living - psychology
,
Aged
,
Analysis
2016
To assess cataract surgery outcome using the Rasch scaled Chinese version of the Catquest short-form.
The Chinese translated and culturally adapted version of the Catquest-9SF was interviewer-administered to patients, pre and post cataract surgery. Rasch analysis was performed on the baseline data to revise the Catquest. For the surgical outcome assessment, we stacked pre- and post-surgical Catquest data to demonstrate improvement in visual function scores and responsiveness of the instrument to cataract surgery.
A total of 247 cataract patients (median age, 70 yrs; male 51.0%) completed the Catquest 9SF at baseline.The Catquest-9SF possessed adequate measurement precision of 2.15. No disordering of response categories were observed and all the items perfectly fit to the Rasch model except item 7 (outfit >1.5). A slight reduction in precision was observed after removing misfitting item 7 (Catquest-8SF-CN), but the precision value was well above the acceptable value of 2.00. Notably, the instrument was well targeted (mean person location 0.30), demonstrated no evidence of multidimensionality and DIF. At 12 months post-surgery, 74 (30%) patients came for follow-up and completed the Catquest. There was a significant improvement in the Catquest scores post cataract surgery with a considerably large effect size.
The Catquest-8SF-CN demonstrated promising Rasch based psychometric properties and was highly responsive to cataract surgery.
Journal Article
Efficacy and Acceptability of Orthokeratology for Slowing Myopic Progression in Children: A Systematic Review and Meta-Analysis
2015
Background. To evaluate the efficacy and acceptability of orthokeratology for slowing myopic progression in children with a well conducted evidence-based analysis. Design. Meta-analysis. Participants. Children from previously reported comparative studies were treated by orthokeratology versus control. Methods. A systematic literature retrieval was conducted in MEDLINE, EMBASE, Cochrane Library, World Health Organization International Clinical Trials Registry Platform, and ClinicalTrials.gov. The included studies were subjected to meta-analysis using Stata version 10.1. Main Outcome Measures. Axial length change (efficacy) and dropout rates (acceptability) during 2-year follow-up. Results. Eight studies involving 769 subjects were included. At 2-year follow-up, a statistically significant difference was observed in axial length change between the orthokeratology and control groups, with a weighted mean difference (WMD) of −0.25 mm (95% CI, −0.30 to −0.21). The pooled myopic control rate declined with time, with 55, 51, 51, and 41% obtained after 6, 12, 18, and 24 months of treatment, respectively. No statistically significant difference was obtained for dropout rates between the orthokeratology and control groups at 2-year follow-up (OR, 0.79; 95% CI, 0.52 to 1.22). Conclusions. Orthokeratology is effective and acceptable for slowing myopic progression in children with careful education and monitoring.
Journal Article