Magnetic resonance imaging of the left atrial appendage post pulmonary vein isolation: Implications for percutaneous left atrial appendage occlusion
by
Shmatukha, Andriy V., PhD
,
Bastarrika, Gorka, MD
,
Wright, Graham A., PhD
in
Ablation
,
Ablation (Surgery)
,
Atrial fibrillation
2015
Abstract Background There is increasing interest in performing left atrial appendage (LAA) occlusion at the time of atrial fibrillation (AF) ablation procedures. However, to date there has been no description of the acute changes to the LAA immediately following pulmonary vein (PV) isolation and additional left atrium (LA) substrate modification. This study assessed changes in the size and tissue characteristics of the LAA ostium in patients undergoing PV isolation. Methods This series included 8 patients who underwent cardiovascular magnetic resonance evaluation of the LA with delayed enhancement magnetic resonance imaging and contrast enhanced 3-D magnetic resonance angiography pre-, within 48 h of, and 3 months post ablation. Two independent cardiac radiologists evaluated the ostial LAA diameters and area at each time point in addition to the presence of gadolinium enhancement. Results Compared to pre-ablation values, the respective median differences in oblique diameters and LAA area were +1.8 mm, +1.7 mm, and +0.6 cm2 immediately post ablation (all NS) and −2.7 mm, −2.3 mm, and −0.5 cm2 at 3 months (all NS). No delayed enhancement was detected in the LAA post ablation. Conclusion No significant change to LAA diameter, area, or tissue characteristics was noted after PV isolation. While these findings suggest the safety and feasibility of concomitant PV isolation and LAA device occlusion, the variability in the degree and direction of change of the LAA measurements highlights the need for further study.
Journal Article
Early Lung Cancer Detection Using Spiral Computed Tomography and Positron Emission Tomography
by
Bastarrika, Gorka
,
Torre, Wenceslao
,
Pueyo, Jesus
in
Adult
,
Age Distribution
,
Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy
2005
Abstract
Rationale
Lung cancer screening using computed tomography (CT) is effective in detecting lung cancer in early stages. Concerns regarding false-positive rates and unnecessary invasive procedures have been raised.
Objective
To study the efficiency of a lung cancer protocol using spiral CT and F-18-fluorodeoxyglucose positron emission tomography (FDG-PET).
Methods
High-risk individuals underwent screening with annual spiral CTs. Follow-up CTs were done for noncalcified nodules of 5 mm or greater, and FDG-PET was done for nodules 10 mm or larger or smaller (> 7 mm), growing nodules.
Results
A total of 911 individuals completed a baseline CT study and 424 had at least one annual follow-up study. Of the former, 14% had noncalcified nodules of 5 mm or larger, and 3.6% had nodules of 10 mm or larger. Eleven non–small cell lung cancers (NSCLC) and one small cell lung cancer (SCLC) were diagnosed in the baseline study (prevalence rate, 1.32%), and two NSCLCs in the annual study (incidence rate, 0.47%). All NSCLCs (92% of prevalence cancers) were diagnosed in stage I (12 stage IA, 1 stage IB). FDG-PET was helpful for the correct diagnosis in 19 of 25 indeterminate nodules. The sensitivity, specificity, positive predictive value, and negative predictive value of FDG-PET for the diagnosis of malignancy were 69, 91, 90, and 71%, respectively. However, the sensitivity and negative predictive value of the screening algorithm, which included a 3-month follow-up CT for nodules with a negative FDG-PET, was 100%.
Conclusion
A protocol for early lung cancer detection using spiral CT and FDG-PET is useful and may minimize unnecessary invasive procedures for benign lesions.
Journal Article