Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
198
result(s) for
"Baudis, N"
Sort by:
Testing T2K’s Bayesian constraints with priors in alternate parameterisations
by
Cherdack, D.
,
Elias, J.
,
Kudenko, Y.
in
Bayesian Inference
,
Formal Reasoning
,
Non-parametric Inference
2025
Bayesian analysis results require a choice of prior distribution. In long-baseline neutrino oscillation physics, the usual parameterisation of the mixing matrix induces a prior that privileges certain neutrino mass and flavour state symmetries. Here we study the effect of privileging alternate symmetries on the results of the T2K experiment. We find that constraints on the level of CP violation (as given by the Jarlskog invariant) are robust under the choices of prior considered in the analysis. On the other hand, the degree of octant preference for the atmospheric angle depends on which symmetry has been privileged.
Journal Article
Testing T2K’s Bayesian constraints with priors in alternate parameterisations
2025
Bayesian analysis results require a choice of prior distribution. In long-baseline neutrino oscillation physics, the usual parameterisation of the mixing matrix induces a prior that privileges certain neutrino mass and flavour state symmetries. Here we study the effect of privileging alternate symmetries on the results of the T2K experiment. We find that constraints on the level of CP violation (as given by the Jarlskog invariant) are robust under the choices of prior considered in the analysis. On the other hand, the degree of octant preference for the atmospheric angle depends on which symmetry has been privileged.
Journal Article
Signal selection and model-independent extraction of the neutrino neutral-current single \\(^+\\) cross section with the T2K experiment
2025
This article presents a study of single \\(^+\\) production in neutrino neutral-current interactions (NC1\\(^+\\)) using the FGD1 hydrocarbon target of the ND280 detector of the T2K experiment. We report the largest sample of such events selected by any experiment, providing the first new data for this channel in over four decades and the first using a sub-GeV neutrino flux. The signal selection strategy and its performance are detailed together with validations of a robust cross section extraction methodology. The measured flux-averaged integrated cross-section is \\( = (6.07 1.22 ) 10^-41 \\,\\, cm^2/nucleon\\), 1.3~\\(~\\) above the NEUT v5.4.0 expectation.
First differential measurement of the single \\(^+\\) production cross section in neutrino neutral-current scattering
2025
Since its first observation in the 1970s, neutrino-induced neutral-current single positive pion production (NC1\\(^+\\)) has remained an elusive and poorly understood interaction channel. This process is a significant background in neutrino oscillation experiments and studying it further is critical for the physics program of next-generation accelerator-based neutrino oscillation experiments. In this Letter we present the first double-differential cross-section measurement of NC1\\(^+\\) interactions using data from the ND280 detector of the T2K experiment collected in \\(\\)-beam mode. The measured flux-averaged integrated cross-section is \\( = (6.07 1.22 ) 10^-41 \\,\\, cm^2/nucleon\\). We compare the results on a hydrocarbon target to the predictions of several neutrino interaction generators and final-state interaction models. While model predictions agree with the differential results, the data shows a weak preference for a cross-section normalization approximately 30\\% higher than predicted by most models studied in this Letter.
R &D of wavelength-shifting reflectors and characterization of the quantum efficiency of tetraphenyl butadiene and polyethylene naphthalate in liquid argon
2022
Detectors based on liquid argon (LAr) often require surfaces that can shift vacuum ultraviolet (VUV) light and reflect the visible shifted light. For the LAr instrumentation of the LEGEND-200 neutrinoless double beta decay experiment, several square meters of wavelength-shifting reflectors (WLSR) were prepared: the reflector Tetratex® (TTX) was in-situ evaporated with the wavelength shifter tetraphenyl butadiene (TPB). For even larger detectors, TPB evaporation will be more challenging and plastic films of polyethylene naphthalate (PEN) are considered as an option to ease scalability. In this work, we first characterized the absorption (and reflectivity) of PEN, TPB (and TTX) films in response to visible light. We then measured TPB and PEN coupled to TTX in a LAr setup equipped with a VUV sensitive photomultiplier tube. The effective VUV photon yield in the setup was first measured using an absorbing reference sample, and the VUV reflectivity of TTX quantified. The characterization and simulation of the setup along with the measurements and modelling of the optical parameters of TPB, PEN and TTX allowed to estimate the absolute quantum efficiency (QE) of TPB and PEN in LAr (at 87K) for the first time: these were found to be above 67 and 49%, respectively (at 90% CL). These results provide relevant input for the optical simulations of experiments that use TPB in LAr, such as LEGEND-200, and for experiments that plan to use TPB or PEN to shift VUV scintillation light.
Journal Article
Removing krypton from xenon by cryogenic distillation to the ppq level
by
Garbini, M.
,
Aprile, E.
,
Sartorelli, G.
in
Astronomy
,
Astrophysics and Cosmology
,
Background radiation
2017
The XENON1T experiment aims for the direct detection of dark matter in a detector filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the
β
-emitter
85
Kr which is present in the xenon. For XENON1T a concentration of natural krypton in xenon
nat
Kr
/
Xe
<
200
ppq
(parts per quadrillion,
1
ppq
=
10
-
15
mol
/
mol
) is required. In this work, the design, construction and test of a novel cryogenic distillation column using the common McCabe–Thiele approach is described. The system demonstrated a krypton reduction factor of
6.4
·
10
5
with thermodynamic stability at process speeds above 3 kg/h. The resulting concentration of
nat
Kr
/
Xe
<
26
ppq
is the lowest ever achieved, almost one order of magnitude below the requirements for XENON1T and even sufficient for future dark matter experiments using liquid xenon, such as XENONnT and DARWIN.
Journal Article
Material radioassay and selection for the XENON1T dark matter experiment
by
Garbini, M.
,
Aprile, E.
,
Sartorelli, G.
in
Astronomy
,
Astrophysics and Cosmology
,
Computer simulation
2017
The XENON1T dark matter experiment aims to detect weakly interacting massive particles (WIMPs) through low-energy interactions with xenon atoms. To detect such a rare event necessitates the use of radiopure materials to minimize the number of background events within the expected WIMP signal region. In this paper we report the results of an extensive material radioassay campaign for the XENON1T experiment. Using gamma-ray spectroscopy and mass spectrometry techniques, systematic measurements of trace radioactive impurities in over one hundred samples within a wide range of materials were performed. The measured activities allowed for stringent selection and placement of materials during the detector construction phase and provided the input for XENON1T detection sensitivity estimates through Monte Carlo simulations.
Journal Article
Phenopacket-tools: Building and validating GA4GH Phenopackets
by
Danis, Daniel
,
Groza, Tudor
,
Rekerle, Lauren
in
Analysis
,
BASIC BIOLOGICAL SCIENCES
,
Biology and Life Sciences
2023
The Global Alliance for Genomics and Health (GA4GH) is a standards-setting organization that is developing a suite of coordinated standards for genomics. The GA4GH Phenopacket Schema is a standard for sharing disease and phenotype information that characterizes an individual person or biosample. The Phenopacket Schema is flexible and can represent clinical data for any kind of human disease including rare disease, complex disease, and cancer. It also allows consortia or databases to apply additional constraints to ensure uniform data collection for specific goals. We present phenopacket-tools, an open-source Java library and command-line application for construction, conversion, and validation of phenopackets. Phenopacket-tools simplifies construction of phenopackets by providing concise builders, programmatic shortcuts, and predefined building blocks (ontology classes) for concepts such as anatomical organs, age of onset, biospecimen type, and clinical modifiers. Phenopacket-tools can be used to validate the syntax and semantics of phenopackets as well as to assess adherence to additional user-defined requirements. The documentation includes examples showing how to use the Java library and the command-line tool to create and validate phenopackets. We demonstrate how to create, convert, and validate phenopackets using the library or the command-line application. Source code, API documentation, comprehensive user guide and a tutorial can be found at https://github.com/phenopackets/phenopacket-tools . The library can be installed from the public Maven Central artifact repository and the application is available as a standalone archive. The phenopacket-tools library helps developers implement and standardize the collection and exchange of phenotypic and other clinical data for use in phenotype-driven genomic diagnostics, translational research, and precision medicine applications.
Journal Article
Probing Majorana neutrinos with double-β decay
2019
A discovery that neutrinos are Majorana fermions would have profound implications for particle physics and cosmology. The Majorana character of neutrinos would make possible the neutrinoless double-β (0νββ) decay, a matter-creating process without the balancing emission of antimatter. The GERDA Collaboration searches for the 0νββ decay of 76Ge by operating bare germanium detectors in an active liquid argon shield. With a total exposure of 82.4 kg·year, we observe no signal and derive a lower half-life limit of T
1/2 > 0.9 × 1026 years (90% C.L.). Our T
1/2 sensitivity, assuming no signal, is 1.1 × 1026 years. Combining the latter with those from other 0νββ decay searches yields a sensitivity to the effective Majorana neutrino mass of 0.07 to 0.16 electron volts.
Journal Article
Observation of two-neutrino double electron capture in 124Xe with XENON1T
by
Garbini, M.
,
Aprile, E.
,
Sartorelli, G.
in
639/766/387/1126
,
639/766/419/1131
,
639/766/419/866
2019
Two-neutrino double electron capture (2
ν
ECEC) is a second-order weak-interaction process with a predicted half-life that surpasses the age of the Universe by many orders of magnitude
1
. Until now, indications of 2
ν
ECEC decays have only been seen for two isotopes
2
–
5
,
78
Kr and
130
Ba, and instruments with very low background levels are needed to detect them directly with high statistical significance
6
,
7
. The 2
ν
ECEC half-life is an important observable for nuclear structure models
8
–
14
and its measurement represents a meaningful step in the search for neutrinoless double electron capture—the detection of which would establish the Majorana nature of the neutrino and would give access to the absolute neutrino mass
15
–
17
. Here we report the direct observation of 2
ν
ECEC in
124
Xe with the XENON1T dark-matter detector. The significance of the signal is 4.4 standard deviations and the corresponding half-life of 1.8 × 10
22
years (statistical uncertainty, 0.5 × 10
22
years; systematic uncertainty, 0.1 × 10
22
years) is the longest measured directly so far. This study demonstrates that the low background and large target mass of xenon-based dark-matter detectors make them well suited for measuring rare processes and highlights the broad physics reach of larger next-generation experiments
18
–
20
.
Two-neutrino double electron capture is observed experimentally in
124
Xe with the XENON1T detector, yielding a half-life of 1.8 × 10
22
years.
Journal Article