Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
199
result(s) for
"Bedogni, Francesco"
Sort by:
Predictors of clinical outcomes after edge-to-edge percutaneous mitral valve repair
by
Barbanti, Marco
,
Laudisa, Maria Luisa
,
Curello, Salvatore
in
Aged
,
Aged, 80 and over
,
Cardiac Catheterization - methods
2015
There is limited information on the long-term outcomes and prognostic clinical predictors after edge-to-edge transcatheter mitral valve repair with the MitraClip system.
Consecutive patients with mitral regurgitation (MR) undergoing MitraClip therapy between October 2008 and November 2013 in 4 Italian centers were analyzed. The primary end point of interest was all-cause death. The secondary end point was the composite of all-cause death or rehospitalization for heart failure.
A total of 304 patients were included, of which 79% had functional MR and 17% were in New York Heart Association functional class IV. Acute procedural success was obtained in 92% of cases, with no intraprocedural death. The cumulative incidences of all-cause death were 3.4%, 10.8%, and 18.6% at 30 days, 1 year, and 2 years, respectively. The corresponding incidences of the secondary end point were 4.4%, 22.0%, and 39.7%, respectively. In the Cox multivariate model, New York Heart Association functional class IV at baseline and ischemic MR etiology were found to significantly and independently predict both the primary and the secondary end point. A baseline, left ventricular end-systolic volume >110 mL was found to be an independent predictor of the secondary endpoint. Acute procedural success was independently associated with a lower risk of all-cause death and the combination of all-cause death or rehospitalization for heart failure at long-term follow-up.
In a cohort of patients undergoing MitraClip therapy, those presenting at baseline with ischemic functional etiology, severely dilated ventricles, or advanced heart failure and those undergoing unsuccessful procedures carried the worst prognosis.
Journal Article
Angulation and curvature of aortic landing zone affect implantation depth in transcatheter aortic valve implantation
2024
In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (H
Pre
) and the final (H
Post
) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature (
k
L
Z
,
t
o
t
) and LZ angulation distal to aortic annulus (
α
L
Z
,
D
i
s
t
a
l
) were greater in the SE compared to the BE group (
P
< 0.001 for both). In the BE group, H
Post
was significantly higher than H
Pre
at both cusps (
P
< 0.001). In the SE group, H
Post
was significantly deeper than H
Pre
only at the left coronary cusp (
P
= 0.013). At multivariate analysis,
α
L
Z
,
D
i
s
t
a
l
was the only independent predictor (OR = 1.11,
P
= 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.
Journal Article
Meta-Analysis of the Impact of Mitral Regurgitation on Outcomes After Transcatheter Aortic Valve Implantation
by
Chakravarty, Tarun
,
Barbanti, Marco
,
Thomas, Martyn
in
Aortic Valve Stenosis - complications
,
Aortic Valve Stenosis - surgery
,
Cardiac Catheterization
2015
Significant mitral regurgitation (MR) constitutes an important co-existing valvular heart disease burden in the setting of aortic valve stenosis. There are conflicting reports on the impact of significant MR on outcomes after transcatheter aortic valve implantation (TAVI). We evaluated the impact of MR on outcomes after TAVI by performing a meta-analysis of 8 studies involving 8,927 patients reporting TAVI outcomes based on the presence or absence of moderate-severe MR. Risk ratios (RRs) were calculated using the inverse variance random-effects model. None-mild MR was present in 77.8% and moderate-severe MR in 22.2% of the patients. The presence of moderate-severe MR at baseline was associated with increased mortality at 30 days (RR 1.35, 95% confidence interval [CI] 1.14 to 1.59, p = 0.003) and 1 year (RR 1.24, 95% CI 1.13 to 1.37, p <0.0001). The increased mortality associated with moderate-severe MR was not influenced by the cause of MR (functional or degenerative MR; RR 0.90, 95% CI 0.62 to 1.30, p = 0.56). The severity of MR improved in 61 ± 6.0% of patients after TAVI. Moderate-severe residual MR, compared with none-mild residual MR after TAVI, was associated with significantly increased 1-year mortality (RR 1.48, 95% CI 1.31 to 1.68, p <0.00001). In conclusion, baseline moderate-severe MR and significant residual MR after TAVI are associated with an increase in mortality after TAVI and represent an important group to target with medical or transcatheter therapies in the future.
Journal Article
A multi-center, international, randomized, 2-year, parallel-group study to assess the superiority of IVUS-guided PCI versus qualitative angio-guided PCI in unprotected left main coronary artery (ULMCA) disease: Study protocol for OPTIMAL trial
by
Roberto Scarsini
,
Adrian Banning
,
Giovanni Luigi De Maria
in
Angiography
,
Cardiology
,
Cerebral infarction
2022
Percutaneous coronary intervention (PCI) is used increasingly for revascularization of unprotected left main coronary artery (LMCA) disease. Observational studies and subgroup analyses from clinical trials, have suggested a possible benefit from the use of intravascular ultrasound (IVUS) guidance when performing unprotected LMCA PCI. However, the value of imaging with IVUS has never been proven in an appropriately powered randomized clinical trial. The OPtimizaTIon of Left MAin PCI With IntravascuLar Ultrasound (OPTIMAL) trial has been designed to establish whether IVUS-guided PCI optimization on LMCA is associated with superior clinical outcomes when compared with standard qualitative angiography-guided PCI.
The OPTIMAL trial is a randomized, multicenter, international study designed to enroll a total of 800 patients undergoing PCI for unprotected LMCA disease. Patients will be randomized in a 1:1 fashion to IVUS-guided PCI versus angiogram-guided PCI. In patients allocated to the angiogram-guided arm, use of IVUS is discouraged, unless there are safety concerns. In patients allocated to the IVUS guidance arm, pre-procedural IVUS assessment is highly recommended, whilst post-procedural IVUS assessment is mandatory to confirm appropriate stenting result and/or to guide stent result optimization, according to predefined criteria. Patients will be followed up to 2 years after the index procedure. The primary outcome measure is the Academic Research Consortium (ARC) patient-oriented composite endpoint (PoCE) which includes all-cause death, any stroke, any myocardial infarction and any repeat revascularization at 2 years follow-up.
The OPTIMAL trial aims to provide definitive evidence about the clinical impact of IVUS-guidance during PCI to an unprotected LMCA. It is anticipated by the investigators, that an IVUS-guided strategy will be associated with less clinical events compared to a strategy guided by angiogram alone.
ClinicalTrials.gov: NCT04111770. Registered on October 1, 2019.
Journal Article
Cell-Type-Specific Gene Expression in Developing Mouse Neocortex: Intermediate Progenitors Implicated in Axon Development
2021
Cerebral cortex projection neurons (PNs) are generated from intermediate progenitors (IPs), which are in turn derived from radial glial progenitors (RGPs). To investigate developmental processes in IPs, we profiled IP transcriptomes in embryonic mouse neocortex, using transgenic Tbr2 -GFP mice, cell sorting, and microarrays. These data were used in combination with in situ hybridization to ascertain gene sets specific for IPs, RGPs, PNs, interneurons, and other neural and non-neural cell types. RGP-selective transcripts ( n = 419) included molecules for Notch receptor signaling, proliferation, neural stem cell identity, apical junctions, necroptosis, hippo pathway, and NF-κB pathway. RGPs also expressed specific genes for critical interactions with meningeal and vascular cells. In contrast, IP-selective genes ( n = 136) encoded molecules for activated Delta ligand presentation, epithelial-mesenchymal transition, core planar cell polarity (PCP), axon genesis, and intrinsic excitability. Interestingly, IPs expressed several “dependence receptors” ( Unc5d , Dcc , Ntrk3 , and Epha4 ) that induce apoptosis in the absence of ligand, suggesting a competitive mechanism for IPs and new PNs to detect key environmental cues or die. Overall, our results imply a novel role for IPs in the patterning of neuronal polarization, axon differentiation, and intrinsic excitability prior to mitosis. Significantly, IPs highly express Wnt-PCP, netrin, and semaphorin pathway molecules known to regulate axon polarization in other systems. In sum, IPs not only amplify neurogenesis quantitatively, but also molecularly “prime” new PNs for axogenesis, guidance, and excitability.
Journal Article
Clinical impact and evolution of mitral regurgitation following transcatheter aortic valve replacement: a meta-analysis
by
Dumont, Eric
,
Rodés-Cabau, Josep
,
Barbanti, Marco
in
Aortic Valve Stenosis - complications
,
Aortic Valve Stenosis - diagnosis
,
Aortic Valve Stenosis - mortality
2015
ObjectivesMitral regurgitation (MR) is a common entity in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR), but its influence on outcomes remains controversial. The purpose of this meta-analysis was to assess the clinical impact of and changes in significant (moderate–severe) MR in patients undergoing TAVR, overall and according to valve design (self-expandable (SEV) vs balloon-expandable (BEV)).MethodsAll national registries and randomised trials were pooled using meta-analytical guidelines to establish the impact of moderate–severe MR on mortality after TAVR. Studies reporting changes in MR after TAVR on an individual level were electronically searched and used for the analysis.ResultsEight studies including 8015 patients (SEV: 3474 patients; BEV: 4492 patients) were included in the analysis. The overall 30-day and 1-year mortality was increased in patients with significant MR (OR 1.49, 95% CI 1.16 to 1.92; HR 1.32, 95% CI 1.12 to 1.55, respectively), but a significant heterogeneity across studies was observed (p<0.05). The impact of MR on mortality was not different between SEV and BEV in meta-regression analysis for 30-day (p=0.360) and 1-year (p=0.388) mortality. Changes in MR over time were evaluated in nine studies including 1278 patients. Moderate–severe MR (SEV: 326 patients; BEV: 192 patients) improved in 50.5% of the patients at a median follow-up of 180 (30–360) days after TAVR, and the degree of improvement was greater in patients who had received a BEV (66.7% vs 40.8% in the SEV group, p=0.001).ConclusionsConcomitant moderate–severe MR was associated with increased early and late mortality following TAVR. A significant improvement in MR severity was detected in half of the patients following TAVR, and the degree of improvement was greater in those patients who had received a BEV.
Journal Article
Impact of Institutional Monthly Volume of Transcatheter Edge-to-Edge Repair Procedures for Significant Mitral Regurgitation: Evidence from the GIOTTO-VAT Study
by
Maisano, Francesco
,
Montorfano, Matteo
,
Fiocca, Luigi
in
Aged
,
Aged, 80 and over
,
Calcification
2025
Background and Objectives: Mitral valve transcatheter edge-to-edge repair (TEER) is a widely adopted therapeutic approach for managing significant mitral regurgitation (MR) in high-risk surgical candidates. While procedural safety and efficacy have been demonstrated, the impact of institutional expertise on outcomes remains unclear. We aimed at evaluating whether the institutional monthly volume of TEER influences short- and long-term clinical results. Materials and Methods: This analysis from the multicenter, prospective GIOTTO trial study evaluated the impact of institutional monthly volume on outcomes of TEER to remedy significant mitral regurgitation. Centers were stratified into tertiles based on monthly volumes (≤2.0 cases/month, 2.1–3.5 cases/month, >3.5 cases/month), and key clinical, echocardiographic, and procedural outcomes were analyzed. Statistical analysis was based on standard bivariate tests as well as unadjusted and multivariable adjusted Cox models. Results: A total of 2213 patients were included, stratified into tertiles based on institutional procedural volume: 645 (29.1%) patients in the first tertile, 947 (42.8%) patients in the second tertile, and 621 (28.1%) patients in the third tertile. Several baseline differences were found, with some features disfavoring less busy centers (e.g., functional class and surgical risk, both p < 0.05), and others suggesting a worse risk profile in those treated in busier institutions (e.g., frailty and history of prior mitral valve intervention, both p < 0.05). Procedural success rates were higher in busier centers (p < 0.001), and hospital stay was also shorter there (p < 0.001). Long-term follow-up (median 14 months) suggested worse outcomes in patients treated in less busy centers at unadjusted analysis (e.g., p = 0.018 for death, p = 0.015 for cardiac death, p = 0.014 for death or hospitalization for heart failure, p < 0.001 for cardiac death or hospitalization for heart failure), even if these associations proved no longer significant after multivariable adjustment, except for cardiac death or hospitalization for heart failure, which appeared significantly less common in the busiest centers (p < 0.05). Similar trends were observed when focusing on tertiles of overall center volume and when comparing for each center the first 50 cases with the following ones. Conclusions: High institutional monthly volume of TEER mitral valve repair appears to correlate with an improved procedural success rate and shorter hospitalizations. Similarly favorable results were found for long-term rates of cardiac death or hospitalization for heart failure. These findings inform on the importance of operator experience and center expertise in achieving state-of-the-art results with TEER, while confirming the usefulness of the proctoring approach when naïve centers begin a TEER program.
Journal Article
Safety of a conservative strategy of permanent pacemaker implantation after transcatheter aortic CoreValve implantation
by
Oreglia, Jacopo
,
De Carlo, Marco
,
Petronio, Anna Sonia
in
Aged
,
Aortic Valve Stenosis - diagnosis
,
Aortic Valve Stenosis - surgery
2012
Conduction abnormalities are frequent after transcatheter aortic valve implantation with the CoreValve (Medtronic, Minneapolis, MN) and are often treated with liberal permanent pacemaker (PPM) implantation. Our aim was to assess the 1-year outcome of a conservative approach to pacing and to identify its predictors.
We analyzed 275 consecutive patients without a PPM before transcatheter aortic valve implantation who underwent successful CoreValve implantation at our 3 centers, sharing a conservative approach to pacing.
Of the 47 patients (17.1%) who developed postprocedural complete atrioventricular block, 14 recovered spontaneous atrioventricular conduction <72 hours and did not receive a PPM. Sixty-six patients (24.0%) received a PPM before discharge, and 74 more patients (26.9%) developed a new left bundle-branch block (LBBB). Independent predictors of PPM implantation were as follows: lower CoreValve implantation below the aortic annulus (odds ratio [OR] 1.16/mm, 95% CI 1.03-1.30, P = .01), right bundle-branch block (OR 3.72, 95% CI 1.5-9.2, P = .004), left anterior hemiblock (OR 2.34, 95% CI 1.1-5.1, P = .03), and longer PR interval (OR 1.02/ms, 95% CI 1.00-1.04, P = .03). One-year survival was similar between patients who received a PPM and patients who did not receive a PPM (P = .90), with no case of sudden death in the latter group, and between patients with a new LBBB not receiving a PPM and patients without postprocedural LBBB (P = .37).
A high CoreValve implantation level and avoidance of prophylactic pacing in patients with new LBBB without persistent bradyarrhythmias allowed for a relatively low rate of PPM implantation. This conservative approach spared unwarranted pacing and did not affect 1-year survival.
Journal Article
Lumped-parameter model as a non-invasive tool to assess coronary blood flow in AAOCA patients
2023
Anomalous aortic origin of the coronary artery (AAOCA) is a rare disease associated with sudden cardiac death, usually related to physical effort in young people. Clinical routine tests fail to assess the ischemic risk, calling for novel diagnostic approaches. To this aim, some recent studies propose to assess the coronary blood flow (CBF) in AAOCA by computational simulations but they are limited by the use of data from literature retrieved from normal subjects. To overcome this limitation and obtain a reliable assessment of CBF, we developed a fully patient-specific lumped parameter model based on clinical imaging and in-vivo data retrieved during invasive coronary functional assessment of subjects with AAOCA. In such a way, we can estimate the CBF replicating the two hemodynamic conditions in-vivo analyzed. The model can mimic the effective coronary behavior with high accuracy and could be a valuable tool to quantify CBF in AAOCA. It represents the first step required to move toward a future clinical application with the aim of improving patient care. The study was registered at Clinicaltrial.gov with (ID: NCT05159791, date 2021-12-16).
Journal Article
Cardioembolic sources and stroke prevention: a systematic review
2026
Background
Cardioembolism is one of the most frequent and clinically severe mechanisms underlying ischemic stroke, accounting for a substantial proportion of global morbidity and mortality. Despite declining age-adjusted mortality rates in high-income countries, the absolute number of strokes continues to increase, largely driven by population ageing and the rising prevalence of cardiovascular comorbidities. Timely identification of cardiac sources of embolism is therefore essential to optimize secondary prevention and improve long-term neurological outcomes. The range of potential cardiac substrates is wide and includes atrial fibrillation, native and prosthetic valvular disease, left ventricular thrombus, aortic arch atheroma, intracardiac masses, and right-to-left shunts such as patent foramen ovale.
Main body
Echocardiography represents the cornerstone of the diagnostic work-up in patients with suspected cardioembolic events. Transthoracic echocardiography provides rapid, non-invasive evaluation of cardiac morphology and global function, while transesophageal echocardiography offers superior visualization of high-risk structures, particularly the left atrial appendage, prosthetic valves, and the thoracic aorta. Advances in three-dimensional imaging and Doppler technology have further improved the ability to delineate complex anatomy and hemodynamic abnormalities with high accuracy. Although additional imaging modalities such as cardiac computed tomography and cardiac magnetic resonance may offer complementary anatomical or tissue-characterization data in selected cases, their use should be individualized and reserved for scenarios in which echocardiographic assessment is insufficient to fully characterize a suspected embolic source.
Short conclusions
Cardioembolic stroke continues to represent a major clinical and socioeconomic burden worldwide. While progress in cardiac imaging has substantially improved the detection and characterization of embolic substrates, diagnostic strategies must extend beyond imaging alone. A truly effective and cost-efficient work-up requires integration of clinical information—including patient age, cardiovascular risk profile, predisposing infectious conditions, and overall clinical presentation—to guide appropriate use of diagnostic resources. Incorporating these variables enables more personalized selection of imaging modalities, avoids unnecessary tests, accelerates diagnosis, and ultimately supports more targeted preventive strategies. Strengthening this clinically driven, patient-specific approach is essential to reducing the global impact of embolic stroke and improving cerebrovascular outcomes.
Graphical Abstract
scenario-based diagnostic approach to cardioembolic stroke, guiding tailored imaging strategies and targeted preventive therapy according to patient clinical profile.
Journal Article