Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
41
result(s) for
"Beltramello, Alberto"
Sort by:
First experience and clinical results using a new non-coplanar mono-isocenter technique (HyperArc™) for Linac-based VMAT radiosurgery in brain metastases
by
Gregucci, Fabiana
,
Rigo, Michele
,
Alongi, Filippo
in
Brain cancer
,
Breast cancer
,
Clinical trials
2019
IntroductionRadiosurgery (SRS) or stereotactic fractionated radiotherapy (SFRT) is increasing in the treatment of brain metastases (BMs). Aim of the present study was to evaluate the safety and effectiveness of SRS/SFRT for BMs, using a new mono-isocenter non-coplanar solution (HyperArc™ Varian Medical System).MethodsBMs patients with a diameter inferior to 3 cm, a life expectancy of more than 3 months and a good performance status, were eligible for Linac-based volumetric modulated arc therapy (VMAT) SFRT/SRS with HyperArc™. A retrospective analysis of patients and BMs was performed.ResultsFrom August 2017 to May 2018, 381 BMs in 64 patients were treated and 246 BMs (43 patients, median number of BMs: 5) of them were suitable for analysis. With a median FU time of 6 months, 244 out 246 (99%) BMs were controlled (18% complete response; 41% partial response, 40% stable disease), 2 BMs showed a progression, at the first control. No acute or late toxicities were reported. Median overall survival (OS) has not yet been achieved, while median time to progression was 5 months. In univariate analysis, statistically negative prognostic factors for OS were histology of primary tumor (p = 0.009): lung/breast cancer had better survival rates as compared to others. Cumulative intracranial volume disease ≥ 15 cc and systemic progression disease were independent prognostic factors for OS at univariate (p = 0.04; p = 0.005) and multivariate (p = 0.04; p = 0.009) analysis, respectively.ConclusionThe present first clinical data show that SFRT/SRS with HyperArc™ is safe and effective for BMs patients. The utilization of SFRT/SRS for BMs is promising and should be further explored in randomized trials.
Journal Article
Brain morphometry reproducibility in multi-center 3T MRI studies: A comparison of cross-sectional and longitudinal segmentations
by
Marizzoni, Moira
,
Benninghoff, Jens
,
Alessandrini, Franco
in
Aging - pathology
,
Algorithms
,
Automation
2013
Large-scale longitudinal multi-site MRI brain morphometry studies are becoming increasingly crucial to characterize both normal and clinical population groups using fully automated segmentation tools. The test–retest reproducibility of morphometry data acquired across multiple scanning sessions, and for different MR vendors, is an important reliability indicator since it defines the sensitivity of a protocol to detect longitudinal effects in a consortium. There is very limited knowledge about how across-session reliability of morphometry estimates might be affected by different 3T MRI systems. Moreover, there is a need for optimal acquisition and analysis protocols in order to reduce sample sizes. A recent study has shown that the longitudinal FreeSurfer segmentation offers improved within session test–retest reproducibility relative to the cross-sectional segmentation at one 3T site using a nonstandard multi-echo MPRAGE sequence. In this study we implement a multi-site 3T MRI morphometry protocol based on vendor provided T1 structural sequences from different vendors (3D MPRAGE on Siemens and Philips, 3D IR-SPGR on GE) implemented in 8 sites located in 4 European countries. The protocols used mild acceleration factors (1.5–2) when possible. We acquired across-session test–retest structural data of a group of healthy elderly subjects (5 subjects per site) and compared the across-session reproducibility of two full-brain automated segmentation methods based on either longitudinal or cross-sectional FreeSurfer processing. The segmentations include cortical thickness, intracranial, ventricle and subcortical volumes. Reproducibility is evaluated as absolute changes relative to the mean (%), Dice coefficient for volume overlap and intraclass correlation coefficients across two sessions. We found that this acquisition and analysis protocol gives comparable reproducibility results to previous studies that used longer acquisitions without acceleration. We also show that the longitudinal processing is systematically more reliable across sites regardless of MRI system differences. The reproducibility errors of the longitudinal segmentations are on average approximately half of those obtained with the cross sectional analysis for all volume segmentations and for entorhinal cortical thickness. No significant differences in reliability are found between the segmentation methods for the other cortical thickness estimates. The average of two MPRAGE volumes acquired within each test–retest session did not systematically improve the across-session reproducibility of morphometry estimates. Our results extend those from previous studies that showed improved reliability of the longitudinal analysis at single sites and/or with non-standard acquisition methods. The multi-site acquisition and analysis protocol presented here is promising for clinical applications since it allows for smaller sample sizes per MRI site or shorter trials in studies evaluating the role of potential biomarkers to predict disease progression or treatment effects.
•We implemented a multi-site 3T MRI protocol for brain morphometry on 8EU sites.•We acquired across-session test-retest data on 40 healthy elderly subjects.•We calculated the reproducibility of cortical and volumetric FreeSurfer estimates.•Longitudinal segmentation was more reliable than cross-sectional on all sites.
Journal Article
Demystifying the role of magnetic resonance in identifying intraocular foreign bodies: a case of ocular siderosis
by
Pertile, Grazia
,
Pizzini, Francesca Benedetta
,
Romano, Luigi
in
Acuity
,
Case Report
,
Cataract
2024
Background
Ocular siderosis (OS) is a significant cause of visual loss due to retained ferrous intraocular foreign bodies (IOFB). Despite its rarity, OS can lead to severe visual impairment if not promptly diagnosed and treated. This case is notable due to the occult nature of the IOFB, which was undetected by standard imaging modalities, emphasizing the critical role of magnetic resonance imaging (MRI) in such scenarios.
Case presentation
A 51-year-old Caucasian male presented with progressive vision loss in his right eye over 20 days. Best corrected visual acuity (BCVA) was 20/1000 in the right eye and 20/20 in the left eye. Intraocular pressure (IOP) was 9 mmHg in both eyes. Slit-lamp examination revealed a small linear corneal wound and an iris defect in the right eye, along with a cataract featuring brownish deposits on the anterior capsule. The left eye was normal. Fundus examination of the right eye was hindered by media opacities. Ultrasonography showed a flat retina and choroid with no detectable IOFB. Despite a strong clinical suspicion of OS, computed tomography (CT) did not detect any IOFB. MRI subsequently identified an artifact in the inferior sectors of the right eye, indicative of a metallic IOFB. Surgical intervention involved a 23-gauge vitrectomy, phacoemulsification, IOFB removal and silicon oil (SO) tamponade resulting in a fully restored VA of 20/20 and normal IOP one month post-operation. SO was removed 2 months later. The retina remained adherent with no PVR development, and optical coherence tomography (OCT) scans showed a normal macula.
Conclusions
This case underscores the importance of considering OS in patients with unexplained vision loss and history of ocular trauma, even when initial imaging fails to detect an IOFB. MRI proved crucial in identifying the IOFB, highlighting its value in the diagnostic process. Early detection and surgical removal of IOFBs are essential to prevent irreversible visual damage. This case demonstrates that MRI should be employed when CT and ultrasonography are inconclusive, ensuring accurate diagnosis and timely intervention to preserve vision.
Journal Article
Patient-Specific Detection of Cerebral Blood Flow Alterations as Assessed by Arterial Spin Labeling in Drug-Resistant Epileptic Patients
2015
Electrophysiological and hemodynamic data can be integrated to accurately and precisely identify the generators of abnormal electrical activity in drug-resistant focal epilepsy. Arterial Spin Labeling (ASL), a magnetic resonance imaging (MRI) technique for quantitative noninvasive measurement of cerebral blood flow (CBF), can provide a direct measure of variations in cerebral perfusion associated with the epileptic focus. In this study, we aimed to confirm the ASL diagnostic value in the identification of the epileptogenic zone, as compared to electrical source imaging (ESI) results, and to apply a template-based approach to depict statistically significant CBF alterations. Standard video-electroencephalography (EEG), high-density EEG, and ASL were performed to identify clinical seizure semiology and noninvasively localize the epileptic focus in 12 drug-resistant focal epilepsy patients. The same ASL protocol was applied to a control group of 17 healthy volunteers from which a normal perfusion template was constructed using a mixed-effect approach. CBF maps of each patient were then statistically compared to the reference template to identify perfusion alterations. Significant hypo- and hyperperfused areas were identified in all cases, showing good agreement between ASL and ESI results. Interictal hypoperfusion was observed at the site of the seizure in 10/12 patients and early postictal hyperperfusion in 2/12. The epileptic focus was correctly identified within the surgical resection margins in the 5 patients who underwent lobectomy, all of which had good postsurgical outcomes. The combined use of ESI and ASL can aid in the noninvasive evaluation of drug-resistant epileptic patients.
Journal Article
Degenerative spine disease: Italian position paper on acquisition, interpretation and reporting of Magnetic Resonance Imaging
by
Poletti Mattia
,
Pizzini, Francesca B
,
Bastianello Stefano
in
Biomedical materials
,
Degeneration
,
Degenerative disc disease
2021
ObjectiveTo promote a better radiological interpretation of spine degeneration, a consistent standardization of the acquisition, interpretation and description of Magnetic Resonance Imaging (MRI) l findings.Materials and methodsIn order to achieve this objective, a consensus among experts in imaging of degenerative spine disease (DSD) from Italian radiological societies (SIRM—Italian Society of Radiology, AINR—Italian Association of Neuroradiology) was achieved. The representatives of the Italian inter-societal working group examined the literature produced by European/American task forces on optimizing the study sequences, classification of degenerative disc changes, spondylo-arthrosis, osteochondrosis, synovial and ligament pathologies of the spinal column, and on canal and foraminal stenosis. The document-resulted from the consensus between experts—was then presented to the scientific societies of Neurosurgery (SINCH) and Orthopedics and Traumatology (SIOT) for their approval.ResultsThis position paper presents a proposal for an optimized MRI protocol for studying DSD and provides a glossary of terms related to this pathology and indications on their use. The international terminological recommendations have been translated and adapted to the Italian language and clinical practice and clinical cases have been used to illustrate some of the main classifications.ConclusionsThis revision of international DSD guidelines/recommendations and consensus made it possible to (1) update the nomenclature to international standards and (2) harmonize the MRI protocol and description of radiological findings, adapting both (1, 2) to the Italian context. With this position paper we intend to contribute to an improvement of the communication among doctors and between physicians and their patients as well as the quality of the radiological reports.
Journal Article
Early MRI changes in glioblastoma in the period between surgery and adjuvant therapy
2013
To investigate the increase in MRI contrast enhancement (CE) occurring in glioblastoma during the period between surgery and initiation of chemo-radiotherapy, thirty-seven patients with newly diagnosed glioblastoma were analyzed by early post-operative magnetic resonance (EPMR) imaging within three days of surgery and by pre-adjuvant magnetic resonance (PAMR) examination before adjuvant therapy. Areas of new CE were investigated by use of EPMR diffusion-weighted imaging and PAMR perfusion imaging (by arterial spin-labeling). PAMR was acquired, on average, 29.9 days later than EPMR (range 20–37 days). During this period an increased area of CE was observed for 17/37 patients. For 3/17 patients these regions were confined to areas of reduced EPMR diffusion, suggesting postsurgical infarct. For the other 14/17 patients, these areas suggested progression. For 11/17 patients the co-occurrence of hyperperfusion in PAMR perfusion suggested progression. PAMR perfusion and EPMR diffusion did not give consistent results for 3/17 patients for whom small new areas of CE were observed, presumably because of the poor spatial resolution of perfusion imaging. Before initiation of adjuvant therapy, areas of new CE of resected glioblastomas are frequently observed. Most of these suggest tumor progression, according to EPMR diffusion and PAMR perfusion criteria.
Journal Article
Word and position interference in stroop tasks: a behavioral and fMRI study
by
Pizzini, Francesca Benedetta
,
Zoccatelli, Giada
,
Alessandrini, Franco
in
Adult
,
Analysis of Variance
,
Anatomical correlates of behavior
2010
One of the main features of the attentional system is the capability to select between relevant and irrelevant information. However, irrelevant information interferes with the processing of the relevant one. Using high-field magnetic resonance imaging, we examined the interference effect of a verbal (color-word) and a spatial (arrow-position) Stroop task on the activation of cortical areas known to be dedicated to the attentional control. Behaviorally, we found costs from the irrelevant information in both tasks; in the brain, we found a common neural network of activation that mainly involved the dorsolateral prefrontal cortex and the anterior cingulate cortex. However, the neural circuits involved in the two tasks overlapped only partially, since processing of words in the color-word Stroop task showed a wider and more right-lateralized activation, while spatial processing in the arrow-position Stroop task resulted in a more restricted and left-lateralized activation.
Journal Article
Surgical treatment of high-grade gliomas in motor areas. The impact of different supportive technologies: a 171-patient series
by
Ganau, Mario
,
Santini, Barbara
,
Gambin, Roberta
in
Aged
,
Brain Neoplasms - pathology
,
Brain Neoplasms - physiopathology
2010
In the last few years much has been published to validate new technology in brain mapping for clinical purposes, but there have been few clinical results. In this report we describe our five-year experience in the surgical management of malignant gliomas around motor areas with an evaluation of the impact of functional magnetic resonance imaging (fMRI) plus navigator and intraoperative neurophysiology (IN). End-points were extent of removal, morbidity, and survival. Variables describing patient and tumor characteristics and treatment modalities were statistically weighted in relation to treatment outcome. Tumor depth (
P
= 0.01), midline shift ≥1 cm. (
P
= 0.05), and insular location (
P
= 0.001) negatively affected extent of removal, whereas IN (
P
< 0.001) and fMRI plus navigator (
P
= 0.02) contributed to increasing the rate of total removal (73%, 71% vs. 40%). Postoperative motor impairment was mild and transient in a minority of cases (20%). General complications, as defined by the Glioma Outcome Project, occurred in 23% of cases. IN was the only factor associated with acute postoperative motor deterioration (
P
< 0.001). IN and age >65 years (
P
= 0.01) were associated with the occurrence of complications. Overall survival was significantly higher in patients operated with IN or fMRI plus navigator (
P
< 0.01). Comparing different surgical strategies used in the same period, we observed that supportive technologies in glioma surgery have their primary impact on the quality of resection and survival. IN led to transient motor impairment and some additional complications which did not affect functional outcome.
Journal Article
Visual assessment of medial temporal atrophy on MR films in Alzheimer’s disease: comparison with volumetry
by
Geroldi, Cristina
,
Laakso, Mikko P.
,
Frisoni, Giovanni B.
in
Accuracy
,
Aged
,
Aged, 80 and over
2005
To test the agreement of a visual rating scale of medial temporal lobe atrophy (MTA) with linear and volumetric assessments, and to test its accuracy in discriminating between Alzheimer's disease (AD) patients and controls.
Participants were 28 patients with AD and 29 healthy controls. MTA was evaluated according to Scheltens' five-point scale. Its accuracy in distinguishing AD patients from controls was evaluated as a stand-alone measure and in association with linear [width of the temporal horn (WTH)] and volumetric [hippocampal volume (HV)] measures.
The agreement of this visual rating scale with the other MTA measures was statistically significant (vs WTH and vs HV, p for trend < 0.00005). The visual rating scale showed a good accuracy in distinguishing AD patients from controls [area under the curve (AUC) 0.89, 95% confidence interval (CI) 0.79-0.98]. Although the accuracy of the visual rating scale improved in association with linear WTH (AUC 0.91, 95% CI 0.82-0.99) and in association with HV (AUC 0.93, 95% CI 0.86-1.00), the improvement was not significant.
The visual rating scale of MTA, easily applicable in clinical practice, shows good agreement with more demanding quantitative methods, and can discriminate AD patients from controls with good accuracy.
Journal Article