Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
58 result(s) for "Bernardi, Adriana"
Sort by:
Improving the Energy Efficiency, Limiting Costs and Reducing CO2 Emissions of a Museum Using Geothermal Energy and Energy Management Policies
Museums are major energy consumers amongst buildings, especially if they are housed in historical constructions. Museums usually present high energy demand for the air-conditioning due to their architectonical and structural characteristics, such as the presence of large exhibition rooms and open spaces. At the same time, temperature and humidity have to be strictly controlled in order to assure proper microclimate conditions for the conservation of the housed collections and adequate thermal comfort for visitors and personnel. Moreover, despite being subjected to architectural protection that limits most structural refurbishment interventions, these buildings must be adequate from an energy point of view to allow their reuse or continuity of use according to current quality standards, while retaining their heritage significance. In this awkward context, ground source heat pump working with high temperature terminals is proposed as a viable refurbishment solution. The use of shallow geothermal systems can improve the energy efficiency of the heating ventilation air-conditioning systems and, at the same time, increases the renewable energy source exploitation without affecting the indoor environmental conditions. However, after the interventions, the expected benefits and the sought-after limitation of energy consumption/cost may not occur for different reasons. In fact, even if the installed solution is working perfectly and properly designed, every effort will be in vain if adequate attention is not paid to the management of the plants during the operational phase. This document is meant to evaluate and compare the magnitude that invasive (i.e., technical interventions) and not invasive (i.e., energy management policies) actions respectively and their combined interaction, have on a museum. Through energy simulations it has been possible to quantify the effects that different interventions and energy management strategies had on an existing museum housed in an historical building, from energy consumption, energy costs and CO2 emission standpoints.
Simulation-Based Comparison Between the Thermal Behavior of Coaxial and Double U-Tube Borehole Heat Exchangers
In this study, the thermal behavior of the coaxial and double U borehole heat exchangers was investigated using numerical simulations in both the long- and short-term. As a reference for borehole heat exchanger specifications, the existing coaxial and double U probes of a geothermal heat pump installed within the Horizon 2020 research project named “Cheap GSHPs” were considered. Nine years of simulations revealed that when borehole heat exchangers are subjected to a balanced thermal load, and intermittent operating modes of the ground source heat pump system are set, the coaxial pipes’ configuration provides better thermal performance due to the higher thermal capacitance of the heat-carrier fluid and the lower borehole thermal resistance. The analysis was conducted considering two different types of ground with different thermal conductivity values. As result, the more conductive ground type highlights the higher yield of the coaxial probe.
Potential of GSHP coupled with PV systems for retrofitting urban areas in different European climates based on archetypes definition
•Dataset of energy demand for terrace houses including self-sufficiency indexes.•Archetypes are representative of 3 climatic zones and ground thermal conductivities.•Archetypes’ characterization supports energy policies on ground source heat pumps.•The methodology aims to be replicable supporting district scale retrofit strategies.•Integrated data collection will create the description of the whole building stock. According to the recent policies regarding energy use in buildings and the need of retrofit strategies, the aim of this work is to support policies concerning the installation of ground source heat exchangers in urban and historical areas, raising the awareness on the potential energy saving achievable with optimal sizing and limited impact on the urban environment. Archetypes have been developed distinguishing among existing and historic buildings, focusing on single-family terrace houses, which are the typical residential buildings in European historic centres. A methodology for the optimal sizing of ground source heat pumps, eventually considering dual-source system or air system has been developed combining simulations of a photovoltaic system to estimate the self-sufficiency and the self-consumption for five orientations of the building. Extreme results have been obtained for warm climates, with negligible heating energy demand and possibly free cooling systems rather than traditional cooling systems needed in wintertime. Penalty temperature was acceptable despite unbalanced energy demands. With proper inclination, photovoltaic systems could provide up to 40% of self-sufficiency share also in northern climates. An energy - economic analysis was carried out obtaining a variety of cases representing a general overview of the European building stock and the potential benefits achievable in terms of renewable energy share, energy savings and economic investments needed to be extended to simulations at urban scale. [Display omitted]
Energetic and Exergetic Analysis of Low Global Warming Potential Refrigerants as Substitutes for R410A in Ground Source Heat Pumps
In the European Union (EU), buildings are responsible for about 40% of the total final energy consumption, and 36% of the European global CO2 emissions. The European Commission released directives to push for the enhancement of the buildings energy performance and identified, beside the retrofit of the current building stock, Heating, Ventilation, and Air Conditioning (HVAC) systems as the other main way to increase renewable energy sharing and overall building energy efficiency. For this purpose, Ground Source Heat Pumps (GSHPs) represent one of the most interesting technologies to provide energy for heating, cooling, and domestic water production in residential applications, ensuring a significant reduction (e.g., up to 44% compared with air-source heat pumps) of energy consumption and the corresponding emissions. At present, GSHPs mainly employ the refrigerant R410A as the working fluid, which has a Global Warming Potential (GWP) of 2087. However, following the EU Regulation No. 517/2014 on fluorinated greenhouse gases, this high GWP refrigerant will have to be substituted for residential applications in the next years. Thus, to increase the sustainability of GSHPs, it is necessary to identify short time alternative fluids with lower GWP, before finding medium-long term solutions characterized by very low GWP. This is one of the tasks of the UE project \"Most Easy, Efficient, and Low-Cost Geothermal Systems for Retrofitting Civil and Historical Buildings\" (acronym GEO4CIVHIC). Here, a thorough thermodynamic analysis, based on both energy and exergy analysis, will be presented to perform a comparison between different fluids as substitutes for R410A, considered as the benchmark for GSHP applications. These fluids have been selected considering their lower flammability with respect to hydrocarbons (mainly R290), that is one of the main concerns for the companies. A parametric analysis has been performed, for a reversible GSHP cycle, at various heat source and sink conditions, with the aim to identify the fluid giving the best energetic performance and to evaluate the distribution of the irreversibilities along the cycle. Considering all these factors, R454B turned out to be the most suitable fluid to use in a ground source heat pump, working at given conditions. Special attention has been paid to the compression phase and the heat transfer in evaporator and condenser.
Energetic Analysis of Low Global Warming Potential Refrigerants as Substitutes for R410A and R134a in Ground-Source Heat Pumps
The European building sector is responsible for approximately 40% of total energy consumption and for 36% of greenhouse gas emissions. Identifying technological solutions capable of reducing energy consumption and greenhouse gas emissions is one of the main objectives of the European Commission. Ground source heat pumps (GSHPs) are of particular interest for this purpose, promising a considerable reduction in greenhouse gas emissions of HVAC systems. This paper reports the results of the energetic analysis carried out within the EU research project GEO4CIVHIC about the performance of geothermal heat pumps working with low-GWP refrigerants as alternatives for R134a and R410A. The work has been carried out through computer simulations based on base and regenerative reverse cycles. Several heat sink and heat source temperature conditions have been considered in order to evaluate the GSHPs’ performance in the whole range of real conditions that can be found in Europe. Particular attention has been paid to the evaluation of compression isentropic efficiency and its influence on the overall cycle performance when dealing with steady-state heat pump simulations. To do so, five different scenarios of isentropic efficiency calculation have been studied and discussed.
Evaluation of the Effect of Anti-Corrosion Coatings on the Thermal Resistance of Ground Heat Exchangers for Shallow Geothermal Applications
The materials and the technology used to build the ground heat exchangers significantly affect the heat transfer performance of a geothermal system, in addition to the local geological and hydrogeological context. Among expense items such as the coupled heat pumps and the applied drilling technology, the heat exchangers play a key role in the shallow geothermal market. For this reason, they are usually made with plastic. Metal tubes are not widely used because of corrosion issues, which can compromise the reliability of the system over time. According to best practices, metal is an unfavorable choice if the pipes are not made of corrosion resistant alloys, such as stainless steel, but the overall performance is strongly related to the heat transfer efficiency. In this study, laser-flash technique is applied on carbon steel samples with anti-corrosion coatings and on corrosion resistant materials (stainless steel grades used for pipes), thus, allowing the comparison of their thermophysical properties. These properties are used to evaluate each solution in terms of thermal resistance. This study demonstrates that there are no particular corrosion resistant steel pipe configurations that are thermally favorable over others in a critical way.
Thermal Response Testing Results of Different Types of Borehole Heat Exchangers: An Analysis and Comparison of Interpretation Methods
The design phase of ground source heat pump systems is an extremely important one as many of the decisions made at that time can affect the system’s energy performance as well as installation and operating costs. The current study examined the interpretation of thermal response testing measurements used to evaluate the equivalent ground thermal conductivity and thus to design the system. All the measurements were taken at the same geological site located in Molinella, Bologna (Italy) where a variety of borehole heat exchangers (BHEs) had been installed and investigated within the project Cheap-GSHPs (Cheap and efficient application of reliable Ground Source Heat exchangers and Pumps) of the European Union’s Horizon 2020 research and innovation program. The measurements were initially analyzed in accordance with the common interpretation based on the first-order approximation of the solution for the infinite line source model and then by utilizing the complete solutions of both the infinite line and cylinder source models. An inverse numerical approach based on a detailed model that considers the current geometry of the BHE and the axial heat transfer as well as the effect of weather on the ground surface was also used. Study findings revealed that the best result was generally obtained using the inverse numerical interpretation.
A European Database of Building Energy Profiles to Support the Design of Ground Source Heat Pumps
The design of ground source heat pumps is a fundamental step to ensure the high energy efficiency of heat pump systems throughout their operating years. To enhance the diffusion of ground source heat pump systems, two different tools are developed in the H2020 research project named, “Cheap GSHPs”: A design tool and a decision support system. In both cases, the energy demand of the buildings may not be calculated by the user. The main input data, to evaluate the size of the borehole heat exchangers, is the building energy demand. This paper presents a methodology to correlate energy demand, building typologies, and climatic conditions for different types of residential buildings. Rather than envelope properties, three insulation levels have been considered in different climatic conditions to set up a database of energy profiles. Analyzing European climatic test reference years, 23 locations have been considered. For each location, the overall energy and the mean hourly monthly energy profiles for heating and cooling have been calculated. Pre-calculated profiles are needed to size generation systems and, in particular, ground source heat pumps. For this reason, correlations based on the degree days for heating and cooling demand have been found in order to generalize the results for different buildings. These correlations depend on the Köppen–Geiger climate scale.
Aesthetic compatibility assessment of consolidants for wall paintings by means of multivariate analysis of colorimetric data
Background and methodsWall paintings and architectural surfaces in outdoor environments are exposed to several physical, chemical and biological agents, hence they are often treated with different products to prevent or slow down their deterioration. Among the factors that have to be taken into account in the selection of the most suitable treatment for decorated surfaces, the aesthetic compatibility with the substrate is of great importance in the cultural heritage field; minimizing colour variation after treatment application is a crucial issue in particular for painted surfaces. In the framework of the European Project Nanomatch the color variation induced on wall painting mock-ups by the two innovative consolidants (calcium alkoxides) developed was evaluated using colorimetry in comparison with two traditional products. In this work these innovative consolidants have been also tested in combination with two commercial biocides and the results of colorimetric measurements discussed. Moreover, as the univariate approach didn’t allow to draw clear conclusions on the relation between the different sources of data variability, multivariate analysis was performed on colorimetric data.ResultsPrincipal Component Analysis and multi-way Parallel Factor Analysis (PARAFAC) were successfully applied to colorimetric data to investigate the short-term effects of the application of different consolidants on wall painting surfaces, making it possible to study at the same time the different sources of data variability, i.e. treatments, painting techniques, pigments. Finally, a ranking list of the treatments under study in terms of colour variation induced on the surface was established, in function of the painting technique and pigment, taking also in consideration the combination consolidant/biocide. In particular, given the true multi-way nature of the data, PARAFAC model turned out to be extremely useful in the study of the dependence of colour variation on pigments, a critical issue for painted surfaces, that was not clear using univariate approach.ConclusionsMultivariate approach to colorimetric data and especially 3-way PARAFAC method resulted a powerful technique to evaluate in short-term the color compatibility of consolidants for wall paintings, improving data interpretation and visualization, and thus outperforming the univariate statistical analysis.
Generalized Pan-European Geological Database for Shallow Geothermal Installations
The relatively high installation costs for different types of shallow geothermal energy systems are obstacles that have lowered the impact of geothermal solutions in the renewable energy market. In order to reduce planning costs and obtain a lithological overview of geothermal potentials and drilling conditions, a pan-European geological overview map was created using freely accessible JRC (Joint Research Centre) data and ArcGIS software. JRC data were interpreted and merged together in order to collect information about the expenditure of installing geothermal systems in specific geological set-ups, and thereby select the most economic drilling technique. Within the four-year project of the European Union’s Horizon 2020 Research and Innovation Program, which is known as “Cheap-GSHPs” (the Cheap and efficient application of reliable Ground Source Heat exchangers and Pumps), the most diffused lithologies and corresponding drilling costs were analyzed to provide a 1 km × 1 km raster with the required underground information. The final outline map should be valid throughout Europe, and should respect the INSPIRE (INfrastructure for SPatial InfoRmation in Europe) guidelines.