Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Language
      Language
      Clear All
      Language
  • Subject
      Subject
      Clear All
      Subject
  • Item Type
      Item Type
      Clear All
      Item Type
  • Discipline
      Discipline
      Clear All
      Discipline
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
2 result(s) for "Bhadauria, Vishal"
Sort by:
Exposure assessment of PM2.5 in temple premises and crematoriums in Kanpur, India
Regular use of incense and earthen lamps in temples leads to the release of particulate matter (PM), airborne flecks, and gaseous pollutants. Similarly, the cremation of dead bodies using timber and other accessories such as incense, organic chemicals containing carbon, and clothes generates air pollutants. It is currently unclear how much emissions and exposure these activities may lead. This work attempts to fill this gap in our understanding by assessing the associated emissions of PM 2.5 and the corresponding exposure. Ten temples and two cremation grounds were considered for the sampling of PM 2.5 . The average PM 2.5 concentration at the ten temples and the two crematoriums was found to be 658.30 ± 112.63 µg/m 3 and 1043.50 ± 191.63 µg/m 3 , respectively. The range of real-time PM 2.5 data obtained from the nearest twelve stations located in the vicinity was 113–191 µg/m 3 . The exposure assessment in terms of deposition dose was carried out using the ICRP model. The maximum and minimum total respiratory deposition dose rate for PM 2.5 for temples was 175.75 µg/min and 101.15 µg/min, respectively. For crematoriums, the maximum and minimum value of same was 252.3 µg/min and 194.31 µg/min, respectively, for an exposure period of 10 min.
Exposure assessment of PM 2.5 in temple premises and crematoriums in Kanpur, India
Regular use of incense and earthen lamps in temples leads to the release of particulate matter (PM), airborne flecks, and gaseous pollutants. Similarly, the cremation of dead bodies using timber and other accessories such as incense, organic chemicals containing carbon, and clothes generates air pollutants. It is currently unclear how much emissions and exposure these activities may lead. This work attempts to fill this gap in our understanding by assessing the associated emissions of PM and the corresponding exposure. Ten temples and two cremation grounds were considered for the sampling of PM . The average PM concentration at the ten temples and the two crematoriums was found to be 658.30 ± 112.63 µg/m and 1043.50 ± 191.63 µg/m , respectively. The range of real-time PM data obtained from the nearest twelve stations located in the vicinity was 113-191 µg/m . The exposure assessment in terms of deposition dose was carried out using the ICRP model. The maximum and minimum total respiratory deposition dose rate for PM for temples was 175.75 µg/min and 101.15 µg/min, respectively. For crematoriums, the maximum and minimum value of same was 252.3 µg/min and 194.31 µg/min, respectively, for an exposure period of 10 min.