Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
34 result(s) for "Bhuva, Anish N"
Sort by:
Improving the Generalizability of Convolutional Neural Network-Based Segmentation on CMR Images
Convolutional neural network (CNN) based segmentation methods provide an efficient and automated way for clinicians to assess the structure and function of the heart in cardiac MR images. While CNNs can generally perform the segmentation tasks with high accuracy when training and test images come from the same domain (e.g., same scanner or site), their performance often degrades dramatically on images from different scanners or clinical sites. We propose a simple yet effective way for improving the network generalization ability by carefully designing data normalization and augmentation strategies to accommodate common scenarios in multi-site, multi-scanner clinical imaging data sets. We demonstrate that a neural network trained on a single-site single-scanner dataset from the UK Biobank can be successfully applied to segmenting cardiac MR images across different sites and different scanners without substantial loss of accuracy. Specifically, the method was trained on a large set of 3,975 subjects from the UK Biobank. It was then directly tested on 600 different subjects from the UK Biobank for intra-domain testing and two other sets for cross-domain testing: the ACDC dataset (100 subjects, 1 site, 2 scanners) and the BSCMR-AS dataset (599 subjects, 6 sites, 9 scanners). The proposed method produces promising segmentation results on the UK Biobank test set which are comparable to previously reported values in the literature, while also performing well on cross-domain test sets, achieving a mean Dice metric of 0.90 for the left ventricle, 0.81 for the myocardium, and 0.82 for the right ventricle on the ACDC dataset; and 0.89 for the left ventricle, 0.83 for the myocardium on the BSCMR-AS dataset. The proposed method offers a potential solution to improve CNN-based model generalizability for the cross-scanner and cross-site cardiac MR image segmentation task.
Echocardiographic and Cardiac Magnetic Resonance Imaging-Derived Strains in Relation to Late Gadolinium Enhancement in Hypertrophic Cardiomyopathy
We compared speckle tracking echocardiography (STE) and feature tracking cardiovascular magnetic resonance (FT-CMR) in patients with hypertrophic cardiomyopathy (HC) with a varying extent of fibrosis as defined by late gadolinium enhancement to look at the level of agreement between methods and their ability to relate those to myocardial fibrosis. At 2 reference centers, 79 patients with HC and 16 volunteers (the control group) underwent STE and CMR with late gadolinium enhancement and FT-CMR. Patients were classified into 3 categories: no detectable, limited, and extensive fibrosis. Global longitudinal strain (GLS) and global radial strain (GRS) were derived using FT-CMR and STE. STE-derived GRS was decreased in all HC categories compared with the control group (p <0.001), whereas FT-CMR GRS was reduced only in patients with HC with fibrosis (p <0.05). Reduced STE-derived GLS was associated with extensive fibrosis (p <0.05) and a value less than −15.2% identified those with extensive fibrosis (sensitivity 79%, specificity 92%, area under the curve 0.863, 95% confidence interval [CI] 0.76 to 0.97, p <0.001). Inter-modality agreement was moderate for STE versus CMR-GLS (overall population intra-class correlation coefficient = 0.615, 95% CI 0.42 to 0.75, p <0.001; patients with HC 0.63, 0.42 to 0.76, p <0.001) and GRS (overall population intra-class correlation coefficient = 0.601, 95% CI 0.397 to 0.735, p <0.001). A low level of agreement for GRS was seen between methods in patients with HC. In conclusion, strain indexes measured using echocardiography and CMR are reduced in patients with HC compared with the control group and correlate well with the burden of myocardial fibrosis. Reduced STE-GLS can identify patients with extensive fibrosis, but whether there is an added value for risk stratification for sudden cardiac death remains to be determined.
Defining left ventricular remodeling following acute ST-segment elevation myocardial infarction using cardiovascular magnetic resonance
The assessment of post-myocardial infarction (MI) left ventricular (LV) remodeling by cardiovascular magnetic resonance (CMR) currently uses criteria defined by echocardiography. Our aim was to provide CMR criteria for assessing LV remodeling following acute MI. Firstly, 40 reperfused ST-segment elevation myocardial infarction (STEMI) patients with paired acute (4 ± 2 days) and follow-up (5 ± 2 months) CMR scans were analyzed by 2 independent reviewers and the minimal detectable changes (MDCs) for percentage change in LV end-diastolic volume (%ΔLVEDV), LV end-systolic volume (%ΔLVESV), and LV ejection fraction (%ΔLVEF) between the acute and follow-up scans were determined. Secondly, in 146 reperfused STEMI patients, receiver operator characteristic curve analyses for predicting LVEF <50% at follow-up (as a surrogate for clinical poor clinical outcome) were undertaken to obtain cut-off values for %ΔLVEDV and %ΔLVESV. The MDCs for %ΔLVEDV, %ΔLVESV, and %ΔLVEF were similar at 12%, 12%, 13%, respectively. The cut-off values for predicting LVEF < 50% at follow-up were 11% for %ΔLVEDV on receiver operating characteristic curve analysis (area under the curve (AUC) 0.75, 95% CI 0.6 to 0.83, sensitivity 72% specificity 70%), and 5% for %ΔLVESV (AUC 0.83, 95% CI 0.77 to 0.90, sensitivity and specificity 78%). Using cut-off MDC values (higher than the clinically important cut-off values) of 12% for both %ΔLVEDV and %ΔLVESV, 4 main patterns of LV remodeling were identified in our cohort: reverse LV remodeling (LVEF predominantly improved); no LV remodeling (LVEF predominantly unchanged); adverse LV remodeling with compensation (LVEF predominantly improved); and adverse LV remodeling (LVEF unchanged or worsened). The MDCs for %ΔLVEDV and %ΔLVESV between the acute and follow-up CMR scans of 12% each may be used to define adverse or reverse LV remodeling post-STEMI. The MDC for %ΔLVEF of 13%, relative to baseline, provides the minimal effect size required for investigating treatments aimed at improving LVEF following acute STEMI.
Prognostic utility and characterization of left ventricular hypertrophy using global thickness
Cardiovascular magnetic resonance (CMR) can accurately measure left ventricular (LV) mass, and several measures related to LV wall thickness exist. We hypothesized that prognosis can be used to select an optimal measure of wall thickness for characterizing LV hypertrophy. Subjects having undergone CMR were studied (cardiac patients, n = 2543; healthy volunteers, n = 100). A new measure, global wall thickness (GT, GTI if indexed to body surface area) was accurately calculated from LV mass and end-diastolic volume. Among patients with follow-up (n = 1575, median follow-up 5.4 years), the most predictive measure of death or hospitalization for heart failure was LV mass index (LVMI) (hazard ratio (HR)[95% confidence interval] 1.16[1.12–1.20], p < 0.001), followed by GTI (HR 1.14[1.09–1.19], p < 0.001). Among patients with normal findings (n = 326, median follow-up 5.8 years), the most predictive measure was GT (HR 1.62[1.35–1.94], p < 0.001). GT and LVMI could characterize patients as having a normal LV mass and wall thickness, concentric remodeling, concentric hypertrophy, or eccentric hypertrophy, and the three abnormal groups had worse prognosis than the normal group (p < 0.05 for all). LV mass is highly prognostic when mass is elevated, but GT is easily and accurately calculated, and adds value and discrimination amongst those with normal LV mass (early disease).
Use of quantitative cardiovascular magnetic resonance myocardial perfusion mapping for characterization of ischemia in patients with left internal mammary coronary artery bypass grafts
Background Quantitative myocardial perfusion mapping using cardiovascular magnetic resonance (CMR) is validated for myocardial blood flow (MBF) estimation in native vessel coronary artery disease (CAD). Following coronary artery bypass graft (CABG) surgery, perfusion defects are often detected in territories supplied by the left internal mammary artery (LIMA) graft, but their interpretation and subsequent clinical management is variable. Methods We assessed myocardial perfusion using quantitative CMR perfusion mapping in 38 patients with prior CABG surgery, all with angiographically-proven patent LIMA grafts to the left anterior descending coronary artery (LAD) and no prior infarction in the LAD territory. Factors potentially determining MBF in the LIMA–LAD myocardial territory, including the impact of delayed contrast arrival through the LIMA graft were evaluated. Results Perfusion defects were reported on blinded visual analysis in the LIMA–LAD territory in 27 (71%) cases, despite LIMA graft patency and no LAD infarction. Native LAD chronic total occlusion (CTO) was a strong independent predictor of stress MBF (B = − 0.41, p = 0.014) and myocardial perfusion reserve (MPR) (B = − 0.56, p = 0.005), and was associated with reduced stress MBF in the basal (1.47 vs 2.07 ml/g/min; p = 0.002) but not the apical myocardial segments (1.52 vs 1.87 ml/g/min; p = 0.057). Extending the maximum arterial time delay incorporated in the quantitative perfusion algorithm, resulted only in a small increase (3.4%) of estimated stress MBF. Conclusions Perfusion defects are frequently detected in LIMA–LAD subtended territories post CABG despite LIMA patency. Although delayed contrast arrival through LIMA grafts causes a small underestimation of MBF, perfusion defects are likely to reflect true reductions in myocardial blood flow, largely due to proximal native LAD disease.
Repeatability of Cardiac Magnetic Resonance Radiomics: A Multi-Centre Multi-Vendor Test-Retest Study
Aims: To evaluate the repeatability of cardiac magnetic resonance (CMR) radiomics features on test-retest scanning using a multi-centre multi-vendor dataset with a varied case-mix. Methods and Results: The sample included 54 test-retest studies from the VOLUMES resource (thevolumesresource.com). Images were segmented according to a pre-defined protocol to select three regions of interest (ROI) in end-diastole and end-systole: right ventricle, left ventricle (LV), and LV myocardium. We extracted radiomics shape features from all three ROIs and, additionally, first-order and texture features from the LV myocardium. Overall, 280 features were derived per study. For each feature, we calculated intra-class correlation coefficient (ICC), within-subject coefficient of variation, and mean relative difference. We ranked robustness of features according to mean ICC stratified by feature category, ROI, and cardiac phase, demonstrating a wide range of repeatability. There were features with good and excellent repeatability (ICC ≥ 0.75) within all feature categories and ROIs. A high proportion of first-order and texture features had excellent repeatability (ICC ≥ 0.90), however, these categories also contained features with the poorest repeatability (ICC < 0.50). Conclusion: CMR radiomic features have a wide range of repeatability. This paper is intended as a reference for future researchers to guide selection of the most robust features for clinical CMR radiomics models. Further work in larger and richer datasets is needed to further define the technical performance and clinical utility of CMR radiomics.
Measurement of T1 Mapping in Patients With Cardiac Devices: Off-Resonance Error Extends Beyond Visual Artifact but Can Be Quantified and Corrected
Background: Measurement of myocardial T1 is increasingly incorporated into standard cardiovascular magnetic resonance (CMR) protocols, however accuracy may be reduced in patients with metallic cardiovascular implants. Measurement is feasible in segments free from visual artifact, but there may still be off-resonance induced error. Aim: To quantify off-resonance induced T1 error in patients with metallic cardiovascular implants, and validate a method for error correction for a conventional MOLLI pulse sequence. Methods: Twenty-four patients with cardiac implantable electronic devices (CIEDs: 46% permanent pacemakers, PPMs; 33% implantable loop recorders, ILRs; and 21% implantable cardioverter-defibrillators, ICDs); and 31 patients with aortic valve replacement (AVR) (45% metallic) were studied. Paired mid-myocardial short-axis MOLLI and single breath-hold off-resonance field maps were acquired at 1.5 T. T1 values were measured by AHA segment, and segments with visual artifact were excluded. T1 correction was applied using a published relationship between off-resonance and T1. The accuracy of the correction was assessed in 10 healthy volunteers by measuring T1 before and after external placement of an ICD generator next to the chest to generate off-resonance. Results: T1 values in healthy volunteers with an ICD were underestimated compared to without (967 ± 52 vs. 997 ± 26 ms respectively, p = 0.0001), but were similar after correction ( p = 0.57, residual difference 2 ± 27 ms). Artifact was visible in 4 ± 12, 42 ± 31, and 53 ± 27% of AHA segments in patients with ILRs, PPMs, and ICDs, respectively. In segments without artifact, T1 was underestimated by 63 ms (interquartile range: 7–143) per patient. The greatest error for patients with ILRs, PPMs and ICDs were 79, 146, and 191 ms, respectively. The presence of an AVR did not generate T1 error. Conclusion: Even when there is no visual artifact, there is error in T1 in patients with CIEDs, but not AVRs. Off-resonance field map acquisition can detect error in measured T1, and a correction can be applied to quantify T1 MOLLI accurately.
Metabolic Markers of Mortality Risk in Patients With Severe Aortic Stenosis Undergoing Valve Replacement
In patients with aortic stenosis (AS), the relation of cardiac energetic pathways with cardiac structure and function, their changes, and their prognostic significance are not well understood. We aimed to characterize metabolic profiles in patients with severe AS before and after aortic valve replacement (AVR) and their association with functional status, structural remodeling and mortality. Patients with symptomatic, severe AS before (n = 143) and 1-year after (n = 113) AVR underwent cardiac magnetic resonance (CMR), serum cardiac biomarkers, and 6-minute walk test. Resting nonfasting plasma samples underwent targeted nuclear magnetic resonance (NMR) for fatty acids (FA), branched chain amino acids (BCAAs), glycolysis-related metabolites, and ketones. Lower FA and BCAA concentrations, but not glycolysis metabolites or ketones, correlated with greater myocardial mass and focal fibrosis, NT-proBNP, TnT and 6-minute walk distance. After 10.5 years of follow-up (66/143 deaths), lower FAs and BCAAs, but not ketones were independently associated with higher mortality risk (p <0.05). At 1-year after AVR, FAs had decreased compared to baseline. In conclusion, reduced serum FA and BCAA concentrations are cardiac, maladaptive, prognostic metabolic changes to AS, which are not reversible after AVR. Whether these markers may be used to guide the timing of AVR or provide metabolic risk stratification remains to be evaluated by future research. In patients with AS systemic metabolomics and their association with myocardial remodeling and outcome after AVR are largely unknown. We show that in severe AS low levels of unsaturated FA and BCAAs correlate with higher mortality risk, and biomarkers measured by CMR, serum, and functional incapacity, and do not increase after AVR. This may provide an alternate approach to risk stratification using blood biomarkers or guide targeted therapies to myocardial energetics before or after AVR. Metabolites in severe aortic stenosis and their associations with cardiac remodeling/damage and mortality after aortic valve replacement (AVR). FFAs indicates free fatty acids; BCAA, branched chained amino acids. [Display omitted]
Impact of microvascular obstruction on semiautomated techniques for quantifying acute and chronic myocardial infarction by cardiovascular magnetic resonance
AimsThe four most promising semiautomated techniques (5-SD, 6-SD, Otsu and the full width half maximum (FWHM)) were compared in paired acute and follow-up cardiovascular magnetic resonance (CMR), taking into account the impact of microvascular obstruction (MVO) and using automated extracellular volume fraction (ECV) maps for reference. Furthermore, their performances on the acute scan were compared against manual myocardial infarct (MI) size to predict adverse left ventricular (LV) remodelling (≥20% increase in end-diastolic volume).Methods40 patients with reperfused ST segment elevation myocardial infarction (STEMI) with a paired acute (4±2 days) and follow-up CMR scan (5±2 months) were recruited prospectively. All CMR analysis was performed on CVI42.ResultsUsing manual MI size as the reference standard, 6-SD accurately quantified acute (24.9±14.0%LV, p=0.81, no bias) and chronic MI size (17.2±9.7%LV, p=0.88, no bias). The performance of FWHM for acute MI size was affected by the acquisition sequence used. Furthermore, FWHM underestimated chronic MI size in those with previous MVO due to the significantly higher ECV in the MI core on the follow-up scans previously occupied by MVO (82 (75–88)% vs 62 (51–68)%, p<0.001). 5-SD and Otsu were precise but overestimated acute and chronic MI size. All techniques were performed with high diagnostic accuracy and equally well to predict adverse LV remodelling.Conclusions6-SD was the most accurate for acute and chronic MI size and should be the preferred semiautomatic technique in randomised controlled trials. However, 5-SD, FWHM and Otsu could also be used when precise MI size quantification may be adequate (eg, observational studies).
MRI for patients with cardiac implantable electronic devices: simplifying complexity with a ‘one-stop’ service model
BackgroundPatients with cardiac pacemakers and defibrillators are disadvantaged because of poor access to MRI scans, leading to late and misdiagnosis particularly for cancer and neurological disease. New technology allied to tested protocols now allows safe MRI scanning of such patients; however, logistical barriers persist.AimTo deliver a streamlined sustainable service that provides timely MRI scans to patients with cardiac implantable electronic devices (CIEDs).MethodsPatients requested a ‘one-stop’ service for MRI, whereby devices could be reprogrammed and scans acquired at a single location and visit. To provide this ‘one-stop’ service, we trained a team including administrators, physicians, cardiac physiologists and radiographers. A standard protocol was used to prevent unnecessary request refusals and delays to scheduling. Service volume, waiting time and safety were analysed 6 months before and 2 years after service redesign. Waiting times for internal and external inpatient referrals plus time to treatment for patients on a cancer pathway were analysed.Results215 MRI scans were performed over 2 years. After service redesign, MRI provision increased six-fold to 20 times the national average with reduced waiting time from 60 to 15 days and no adverse events. Departmental throughput was maintained. 85 (40%) referrals were external. 41 (19%) inpatients were scanned, reducing bed-stay by 3 days for internal referrals. 24 (11%) scans were for suspected cancer, 83% allowed treatment within the national standard of 62 days. There was no preintervention service for either inpatients or suspected cancer investigation.ConclusionImplementation of a ‘one-stop’ service model to provide MRI for patients with CIEDs is safe, streamlined, scalable and has reduced delays making economic and clinical sense. Protocols and checklists are available at mrimypacemaker.com.