Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
11 result(s) for "Bijlsma, Lubertus"
Sort by:
Screening of Pharmaceuticals and Illicit Drugs in Wastewater and Surface Waters of Spain and Italy by High Resolution Mass Spectrometry using UHPLC-QTOF MS and LC-LTQ-Orbitrap MS
The existence of pharmaceuticals and illicit drugs (PIDs) in environmental waters has led many analytical chemists to develop screening methods for monitoring purposes. Water samples can contain a huge number of possible contaminants, commonly at low concentrations, which makes their detection and identification problematic. Liquid chromatography coupled with high resolution mass spectrometry (LC-HRMS) has proven itself effective in the screening of environmental contaminants. The present work investigates the use of the most popular HRMS instruments, quadrupole time-of-flight and linear trap quadrupole-Orbitrap, from two different laboratories. A suspect screening for PIDs was carried out on wastewater (influent and effluent) and surface water samples from Castellón, Eastern Spain, and Cremona, Northern Italy, incorporating a database of 107 PIDs (including 220 fragment ions). A comparison between the findings of both instruments and of the samples was made which highlights the advantages and drawbacks of the strategies applied in each case. In total, 28 compounds were detected and/or identified by either/both instruments with irbesartan, valsartan, benzoylecgonine and caffeine being the most commonly found compounds across all samples.
What about the herb? A new metabolomics approach for synthetic cannabinoid drug testing
Synthetic cannabinoids (SCs) are consumed as legal alternative to cannabis and often allow passing drug-screening tests. Their rapid transience on the drug scene, combined with their mostly unknown metabolic profiles, creates a scenario with constantly moving analytical targets, making their monitoring and identification challenging. The development of fast screening strategies for SCs, not directly focused on their chemical structure, as an alternative to the commonly applied target acquisition methods, would be highly appreciated in forensic and public health laboratories. An innovative untargeted metabolomics approach, focused on herbal components commonly used for ‘spice’ products, was applied. Saliva samples of healthy volunteers were collected at pre-dose and after smoking herbal components and analysed by high-resolution mass spectrometry. The data obtained, combined with appropriate statistical analysis, allowed to highlight and elucidate two markers (scopoletin and N,N-bis(2-hydroxyethyl)dodecylamine), which ratio permitted to differentiate herbal smokers from non-smokers. The proposed strategy will allow discriminating potential positives, on the basis of the analysis of two markers identified in the herbal blends. This work is presented as a step forward in SC drug testing, promoting a smart first-line screening approach, which will allow reducing the number of samples to be further investigated by more sophisticated HRMS methods.
In vitro bioanalytical assessment of toxicity of wetland samples from Spanish Mediterranean coastline
BackgroundFresh water bodies represent less than 1% of overall amount of water on earth and ensuring their quality and sustainability is pivotal. Although several campaigns have been performed to monitor the occurrence of micropollutants by means of chemical analysis, this might not cover the whole set of chemicals present in the sample nor the potential toxic effects of mixtures of natural and anthropogenic chemicals. In this sense, by selecting relevant toxicity endpoints when performing in vitro bioanalysis, effect-based methodologies can be of help to perform a comprehensive assessment of water quality and reveal biological activities relevant to adverse health effects. However, no prior bioanalytical study was performed in wetland water samples from the Spanish Mediterranean coastline.MethodsEleven samples from relevant water bodies from the Spanish Mediterranean coastline were collected to monitor water quality on 8 toxicity endpoints. Aryl hydrocarbon receptor (AhR), androgenicity (AR+ and AR−), estrogenicity (ER+ and ER−), oxidative stress response (Nrf2) and vitamin D receptor (VDR+ and VDR−) reporter gene assays were evaluated.ResultsAhR was the reporter gene assay showing a more frequent response over the set of samples (activated by 9 out of 11 samples), with TCDD-eq in the range 7.7–22.2 pM. For AR, ER and VDR assays sporadic activations were observed. Moreover, no activity was observed on the Nrf2 reporter gene assay. Wastewater and street runaway streams from Valencia could be responsible for enhanced activities in one of the water inputs in the Natural Park ‘L’Albufera’.ConclusionsWater quality of relevant wetlands from the Spanish Mediterranean coastline has been evaluated. The utilization of a panel of 5 different bioassays to cover for different toxicity endpoints has demonstrated to be a good tool to assess water quality.
Necroptosis induced by ruthenium (II) complexes as mitochondrial disruptors
Inducing necroptosis in cancer cells has emerged as an effective strategy to overcome drug resistance. However, while organic small molecules have been extensively studied for this purpose, metal-based compounds have received relatively little attention as triggers of necroptosis. The development of ruthenium (II) hybrid compounds, particularly those containing triazene (Ru-TRZ), highlights a novel avenue for modulating necroptotic cell death. Here we show that incorporating a methyltriazene moiety, a known alkylating warhead, confers superior mitochondrial-targeting properties and enhances cell death compared to amide-containing counterparts. Ru-hybrid TRZ2 exhibits also antitumor efficacy against in vivo drug-resistant cancer cells. Mechanistically, we demonstrate that Ru-TRZ hybrids induce apoptosis. In addition, by activating downstream RIPK3-driven cell death, TRZ2 proficiently restrains normal mitochondrial function and activity, leading to cancer cell necroptosis. Finally, TRZ2 synergizes anti-proliferative activity and cell death effects induced by conventional drugs. In conclusion, Ru-TRZ2 stands as a promising ruthenium-based chemotherapeutic agent inducing necroptosis in drug resistant cancer cells.
Isotope pattern deconvolution as a successful alternative to calibration curve for application in wastewater-based epidemiology
An isotope pattern deconvolution (IPD) quantification method has been applied for the determination of five substances (amphetamine, benzoylecgonine, cocaine, methamphetamine and MDMA) in wastewater for the application in wastewater-based epidemiology (WBE). A previously validated method that used a calibration curve for quantification was modified to apply IPD. The two approaches were compared in terms of analytical uncertainty in recovery studies of quality control samples, i.e. six wastewater samples from different geographical origins spiked at two concentration levels. Both methods were reliable as they passed (z-score < 2) in an interlaboratory exercise. After 60 individual determinations, IPD provided 11 results outside recovery limits (70–120%) while the previous method produced 31 adverse results. All mean values for IPD were accurate whereas 6 out of 10 results showed RSD values higher than 30% or recoveries outside limits when using the former method. Moreover, the calculated method bias for the latter doubles that of IPD, which, in turn, makes the combined uncertainty (u(c)) much higher. Consequently, a simple change of data treatment—IPD quantification methodology—resulted in a lower uncertainty of the estimated illicit drug concentration, one of the main steps contributing to the final uncertainty in the normalized daily drug consumption through WBE. The current study demonstrated that the employment of IPD can also be very interesting for future applications of WBE, especially when matrix effects are high, complicating accurate quantification. In addition, when a high number of samples and/or compounds need to be analysed, IPD is faster than calibration and, eventually, cost-effective when isotopically labelled internal standard is highly expensive.
LC-QTOF MS screening of more than 1,000 licit and illicit drugs and their metabolites in wastewater and surface waters from the area of Bogotá, Colombia
A large screening of around 1,000 emerging contaminants, focused on licit and illicit drugs and their metabolites, has been made in urban wastewaters (both influent and effluent) and surface waters from the area of Bogotá, Colombia. After a simple generic solid-phase extraction (SPE) step with Oasis hydrophilic-lipophilic balanced (HLB) cartridges, analyses were made by ultra high-performance liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF MS) under MSᴱ mode (sequential acquisition of mass spectra at low energy (LE) and high collision energy (HE)). Accurate mass measurements and the information provided by MSᴱ on the presence of the (de)protonated molecule and fragment ions allowed the reliable identification of the compounds detected, even without reference standards being available in some cases (tentative identification). The compounds most frequently found were acetaminophen/paracetamol, carbamazepine and its dihydro-dihydroxylated metabolite, clarithromycin, diclofenac, ibuprofen, gemfibrozil, lincomycin, losartan, valsartan, the two metabolites of metamizole (4-acetamido-antipyrine and 4-formylamino-antipyrine), sucralose, and cocaine and its main metabolite benzoylecgonine. Caffeine, the sweetener saccharin, and two hydroxylated metabolites of losartan were tentatively identified in almost all samples analyzed. Pharmaceutical lidocaine was tentatively identified and subsequently confirmed with reference standard. For the first time, a general overview of the occurrence of drugs and their metabolites in the aquatic environment of Colombia has been reported. In the near future, target methodologies, typically based on liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), will need to be set up for accurate and sensitive quantification of the contaminants selected on the basis on the information provided in the present paper.
Improvements in analytical methodology for the determination of frequently consumed illicit drugs in urban wastewater
Rapid and sensitive analytical methodology based on ultra high-performance liquid chromatography-tandem mass spectrometry has been developed for the determination of widely consumed drugs of abuse (amphetamines, MDMA, cocaine, opioids, cannabis and ketamine) and their major metabolites in urban wastewaters. Sample clean-up and pre-concentration was performed by a generic off-line SPE procedure using Oasis HLB. Special effort was made to incorporate amphetamine, which was found highly problematic in the wastewater samples tested, including an additional clean-up with Oasis MCX SPE and dispersive primary secondary amine. Correction for possible SPE losses or degradation during storage was made by the use of isotope-labelled internal standards (ILIS), available for all compounds, which were added to the samples as surrogates. Although ILIS were also efficient for matrix effects correction, the strong ionization suppression observed was not eliminated; therefore, a four-fold dilution prior to SPE was applied to influent wastewaters and a low injection volume was selected (3 μL), in order to reach a compromise between matrix effects, chromatographic performance and sensitivity. The method was validated at 25 and 200 ng L −1 (effluent), and 100 and 800 ng L −1 (influent), obtaining limits of quantification (i.e. the lowest level that the compound can be quantified and also confirmed with at least two MS/MS transitions) between 0.4–25 ng L −1 (effluent) and 2–100 ng L −1 (influent). The applicability of the method was demonstrated by analysis of 14 influent and 14 effluent wastewater samples collected over 2 weeks in Castellón (Spain) within a European collaborative study.
A data-independent acquisition workflow for qualitative screening of new psychoactive substances in biological samples
Identification of new psychoactive substances (NPS) is challenging. Developing targeted methods for their analysis can be difficult and costly due to their impermanence on the drug scene. Accurate-mass mass spectrometry (AMMS) using a quadrupole time-of-flight (QTOF) analyzer can be useful for wide-scope screening since it provides sensitive, full-spectrum MS data. Our article presents a qualitative screening workflow based on data-independent acquisition mode (all-ions MS/MS) on liquid chromatography (LC) coupled to QTOFMS for the detection and identification of NPS in biological matrices. The workflow combines and structures fundamentals of target and suspect screening data processing techniques in a structured algorithm. This allows the detection and tentative identification of NPS and their metabolites. We have applied the workflow to two actual case studies involving drug intoxications where we detected and confirmed the parent compounds ketamine, 25B-NBOMe, 25C-NBOMe, and several predicted phase I and II metabolites not previously reported in urine and serum samples. The screening workflow demonstrates the added value for the detection and identification of NPS in biological matrices.
Inter-laboratory mass spectrometry dataset based on passive sampling of drinking water for non-target analysis
Non-target analysis (NTA) employing high-resolution mass spectrometry is a commonly applied approach for the detection of novel chemicals of emerging concern in complex environmental samples. NTA typically results in large and information-rich datasets that require computer aided (ideally automated) strategies for their processing and interpretation. Such strategies do however raise the challenge of reproducibility between and within different processing workflows. An effective strategy to mitigate such problems is the implementation of inter-laboratory studies (ILS) with the aim to evaluate different workflows and agree on harmonized/standardized quality control procedures. Here we present the data generated during such an ILS. This study was organized through the Norman Network and included 21 participants from 11 countries. A set of samples based on the passive sampling of drinking water pre and post treatment was shipped to all the participating laboratories for analysis, using one pre-defined method and one locally (i.e. in-house) developed method. The data generated represents a valuable resource (i.e. benchmark) for future developments of algorithms and workflows for NTA experiments.
Sewage-based Epidemiology Requires a Truly Transdisciplinary Approach
If asked whether you had consumed illicit drugs recently, would you admit it? If yes, could you precisely recall types of drug, times and amounts used? If you were the person commissioned with the task of quantifying drug use, what approach would you use given the social stigma attached with such behavior? We measure drug residues in sewage, which represents urine of entire populations, to provide an objective estimate of total drug use in a region. In transdisciplinary projects, sewage-based results provide valuable information at unrivaled spatiotemporal resolution complementing traditional data.