Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
123 result(s) for "Bley, Thorsten"
Sort by:
EULAR recommendations for the use of imaging in large vessel vasculitis in clinical practice
To develop evidence-based recommendations for the use of imaging modalities in primary large vessel vasculitis (LVV) including giant cell arteritis (GCA) and Takayasu arteritis (TAK). European League Against Rheumatism (EULAR) standardised operating procedures were followed. A systematic literature review was conducted to retrieve data on the role of imaging modalities including ultrasound, MRI, CT and [18F]-fluorodeoxyglucose positron emission tomography (PET) in LVV. Based on evidence and expert opinion, the task force consisting of 20 physicians, healthcare professionals and patients from 10 EULAR countries developed recommendations, with consensus obtained through voting. The final level of agreement was voted anonymously. A total of 12 recommendations have been formulated. The task force recommends an early imaging test in patients with suspected LVV, with ultrasound and MRI being the first choices in GCA and TAK, respectively. CT or PET may be used alternatively. In case the diagnosis is still in question after clinical examination and imaging, additional investigations including temporal artery biopsy and/or additional imaging are required. In patients with a suspected flare, imaging might help to better assess disease activity. The frequency and choice of imaging modalities for long-term monitoring of structural damage remains an individual decision; close monitoring for aortic aneurysms should be conducted in patients at risk for this complication. All imaging should be performed by a trained specialist using appropriate operational procedures and settings. These are the first EULAR recommendations providing up-to-date guidance for the role of imaging in the diagnosis and monitoring of patients with (suspected) LVV.
Photon-counting CT for diagnosis of acute pulmonary embolism: potential for contrast medium and radiation dose reduction
Objective To evaluate the image quality of an ultra-low contrast medium and radiation dose CT pulmonary angiography (CTPA) protocol for the diagnosis of acute pulmonary embolism using a clinical photon-counting detector (PCD) CT system and compare its performance to a dual-energy-(DE)-CTPA protocol on a conventional energy-integrating detector (EID) CT system. Methods Sixty-four patients either underwent CTPA with the novel scan protocol on the PCD-CT scanner (32 patients, 25 mL, CTDI vol 2.5 mGy·cm) or conventional DE-CTPA on a third-generation dual-source EID-CT (32 patients, 50 mL, CTDI vol 5.1 mGy·cm). Pulmonary artery CT attenuation, signal-to-noise ratio, and contrast-to-noise-ratio were assessed as objective criteria of image quality, while subjective ratings of four radiologists were compared at 60 keV using virtual monoenergetic imaging and polychromatic standard reconstructions. Interrater reliability was determined by means of the intraclass correlation coefficient (ICC). Effective dose was compared between patient cohorts. Results Subjective image quality was deemed superior by all four reviewers for 60-keV PCD scans (excellent or good ratings in 93.8% of PCD vs. 84.4% of 60 keV EID scans, ICC = 0.72). No examinations on either system were considered “non-diagnostic.” Objective image quality parameters were significantly higher in the EID group (mostly p  < 0.001), both in the polychromatic reconstructions and at 60 keV. The ED (1.4 vs . 3.3 mSv) was significantly lower in the PCD cohort ( p  < 0.001). Conclusions PCD-CTPA allows for considerable reduction of contrast medium and radiation dose in the diagnosis of acute pulmonary embolism, while maintaining good to excellent image quality compared to conventional EID-CTPA. Clinical relevance statement Clinical PCD-CT allows for spectral assessment of pulmonary vasculature with high scan speed, which is beneficial in patients with suspected pulmonary embolism, frequently presenting with dyspnea. Simultaneously PCD-CT enables substantial reduction of contrast medium and radiation dose. Key Points • The clinical photon-counting detector CT scanner used in this study allows for high-pitch multi-energy acquisitions. • Photon-counting computed tomography allows for considerable reduction of contrast medium and radiation dose in the diagnosis of acute pulmonary embolism. • Subjective image quality was rated best for 60-keV photon-counting scans.
EULAR recommendations for the use of imaging in large vessel vasculitis in clinical practice: 2023 update
ObjectivesTo update the EULAR recommendations for the use of imaging modalities in primary large vessel vasculitis (LVV).MethodsA systematic literature review update was performed to retrieve new evidence on ultrasound, MRI, CT and [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET) for diagnosis, monitoring and outcome prediction in LVV. The task force consisted of 24 physicians, health professionals and patients from 14 countries. The recommendations were updated based on evidence and expert opinion, iterating until voting indicated consensus. The level of agreement was determined by anonymous votes.ResultsThree overarching principles and eight recommendations were agreed. Compared to the 2018 version, ultrasound is now recommended as first-line imaging test in all patients with suspected giant cell arteritis, and axillary arteries should be included in the standard examination. As an alternative to ultrasound, cranial and extracranial arteries can be examined by FDG-PET or MRI. For Takayasu arteritis, MRI is the preferred imaging modality; FDG-PET, CT or ultrasound are alternatives. Although imaging is not routinely recommended for follow-up, ultrasound, FDG-PET or MRI may be used for assessing vessel abnormalities in LVV patients with suspected relapse, particularly when laboratory markers of inflammation are unreliable. MR-angiography, CT-angiography or ultrasound may be used for long-term monitoring of structural damage, particularly at sites of preceding vascular inflammation.ConclusionsThe 2023 EULAR recommendations provide up-to-date guidance for the role of imaging in the diagnosis and assessment of patients with LVV.
Continuous extracorporeal femoral perfusion model for intravascular ultrasound, computed tomography and digital subtraction angiography
We developed a novel human cadaveric perfusion model with continuous extracorporeal femoral perfusion suitable for performing intra-individual comparison studies, training of interventional procedures and preclinical testing of endovascular devices. Objective of this study was to introduce the techniques and evaluate the feasibility for realistic computed tomography angiography (CTA), digital subtraction angiography (DSA) including vascular interventions, and intravascular ultrasound (IVUS). The establishment of the extracorporeal perfusion was attempted using one formalin-fixed and five fresh-frozen human cadavers. In all specimens, the common femoral and popliteal arteries were prepared, introducer sheaths inserted, and perfusion established by a peristaltic pump. Subsequently, we performed CTA and bilateral DSA in five cadavers and IVUS on both legs of four donors. Examination time without unintentional interruption was measured both with and without non-contrast planning CT. Percutaneous transluminal angioplasty and stenting was performed by two interventional radiologists on nine extremities (five donors) using a broad spectrum of different intravascular devices. The perfusion of the upper leg arteries was successfully established in all fresh-frozen but not in the formalin-fixed cadaver. The experimental setup generated a stable circulation in each procedure (ten upper legs) for a period of more than six hours. Images acquired with CT, DSA and IVUS offered a realistic impression and enabled the sufficient visualization of all examined vessel segments. Arterial cannulating, percutaneous transluminal angioplasty as well as stent deployment were feasible in a way that is comparable to a vascular intervention in vivo. The perfusion model allowed for introduction and testing of previously not used devices. The continuous femoral perfusion model can be established with moderate effort, works stable, and is utilizable for medical imaging of the peripheral arterial system using CTA, DSA and IVUS. Therefore, it appears suitable for research studies, developing skills in interventional procedures and testing of new or unfamiliar vascular devices.
Tin-filtered 100 kV ultra-low-dose CT of the paranasal sinus: Initial clinical results
To investigate the feasibility, diagnostic image quality and radiation dose of 3rd generation dual-source computed tomography (CT) using a tin-filtered 100 kV protocol in patients with suspected acute inflammatory sinus disease. We retrospectively evaluated 109 consecutive patients who underwent CT (Siemens SOMATOM Force, Erlangen, Germany) of the paranasal sinus with a new tin-filtered scan-protocol (Sn100 kV; tube current 35 mAs) using iterative reconstruction. Two readers independently assessed subjective image quality using a five-point Likert scale (1 = excellent, 5 = non-diagnostic). Inter-observer agreement was calculated and expressed as percentage of agreement. Noise was determined for calculation of signal-to-noise-ratio (SNR). Effective radiation dose (ED) was calculated from the dose-length-product (DLP). All examinations showed diagnostic image quality regarding evaluation of inflammatory sinus disease. On average, subjective general image quality was rated moderate (= 3) with a percentage of agreement between the observers of 81%. The mean image noise was 14.3 HU. The calculated median SNR was 6.0 for intraorbital fat, and 3.6 for the vitreous body, respectively. The median DLP was 2.1 mGy*cm, resulting in a median ED of 0.012 mSv. Taking the study limitations into account, ultra-low-dose tin-filtered CT of the paranasal sinus at a tube voltage of 100 kV utilizing an iterative reconstruction algorithm provides for reliable exclusion of suspected acute inflammatory sinus disease in 100% of the cases.
FDG-PET/CT(A) imaging in large vessel vasculitis and polymyalgia rheumatica: joint procedural recommendation of the EANM, SNMMI, and the PET Interest Group (PIG), and endorsed by the ASNC
Large vessel vasculitis (LVV) is defined as a disease mainly affecting the large arteries, with two major variants, Takayasu arteritis (TA) and giant cell arteritis (GCA). GCA often coexists with polymyalgia rheumatica (PMR) in the same patient, since both belong to the same disease spectrum. FDG-PET/CT is a functional imaging technique which is an established tool in oncology, and has also demonstrated a role in the field of inflammatory diseases. Functional FDG-PET combined with anatomical CT angiography, FDG-PET/CT(A), may be of synergistic value for optimal diagnosis, monitoring of disease activity, and evaluating damage progression in LVV. There are currently no guidelines regarding PET imaging acquisition for LVV and PMR, even though standardization is of the utmost importance in order to facilitate clinical studies and for daily clinical practice. This work constitutes a joint procedural recommendation on FDG-PET/CT(A) imaging in large vessel vasculitis (LVV) and PMR from the Cardiovascular and Inflammation & Infection Committees of the European Association of Nuclear Medicine (EANM), the Cardiovascular Council of the Society of Nuclear Medicine and Molecular Imaging (SNMMI), and the PET Interest Group (PIG), and endorsed by the American Society of Nuclear Cardiology (ASNC). The aim of this joint paper is to provide recommendations and statements, based on the available evidence in the literature and consensus of experts in the field, for patient preparation, and FDG-PET/CT(A) acquisition and interpretation for the diagnosis and follow-up of patients with suspected or diagnosed LVV and/or PMR. This position paper aims to set an internationally accepted standard for FDG-PET/CT(A) imaging and reporting of LVV and PMR.
Orbital magnetic resonance imaging of giant cell arteritis with ocular manifestations: a systematic review and individual participant data meta-analysis
Objectives We conducted a systematic review and individual participant data meta-analysis of publications reporting the ophthalmologic presentation, clinical exam, and orbital MRI findings in patients with giant cell arteritis and ocular manifestations. Methods PubMed and Cochrane databases were searched up to January 16, 2022. Publications reporting patient-level data on patients with ophthalmologic symptoms, imaged with orbital MRI, and diagnosed with biopsy-proven giant cell arteritis were included. Demographics, clinical symptoms, exam, lab, imaging, and outcomes data were extracted. The methodological quality and completeness of reporting of case reports were assessed. Results Thirty-two studies were included comprising 51 patients (females = 24; median age, 76 years). Vision loss (78%) and headache (45%) were commonly reported visual and cranial symptoms. Ophthalmologic presentation was unilateral (41%) or bilateral (59%). Fundus examination most commonly showed disc edema (64%) and pallor (49%). Average visual acuity was very poor (2.28 logMAR ± 2.18). Diagnoses included anterior (61%) and posterior (16%) ischemic optic neuropathy, central retinal artery occlusion (8%), and orbital infarction syndrome (2%). On MRI, enhancement of the optic nerve sheath (53%), intraconal fat (25%), and optic nerve/chiasm (14%) was most prevalent. Among patients with monocular visual symptoms, 38% showed pathologic enhancement in the asymptomatic orbit. Six of seven cases reported imaging resolution after treatment on follow-up MRIs. Conclusions Vision loss, pallid disc edema, and optic nerve sheath enhancement are the most common clinical, fundoscopic, and imaging findings reported in patients diagnosed with giant cell arteritis with ocular manifestations, respectively. MRI may detect subclinical inflammation and ischemia in the asymptomatic eye and may be an adjunct diagnostic tool. Clinical relevance statement Brain and orbital MRIs may have diagnostic and prognostic roles in patients with suspected giant cell arteritis who present with ophthalmic symptoms.
Virtual non-iodine photon-counting CT-angiography for aortic valve calcification scoring
Photon-counting detector (PCD)-CT allows for reconstruction of virtual non-iodine (VNI) images from contrast-enhanced datasets. This study assesses the diagnostic performance of aortic valve calcification scoring (AVCS) derived from VNI datasets generated with a 1st generation clinical dual-source PCD-CT. AVCS was evaluated in 123 patients (statistical analysis only comprising patients with aortic valve calcifications [n = 56; 63.2 ± 11.6 years]), who underwent contrast enhanced electrocardiogram-gated (either prospective or retrospective or both) cardiac CT on a clinical PCD system. Patient data was reconstructed at 70 keV employing a VNI reconstruction algorithm. True non-contrast (TNC) scans at 70 keV without quantum iterative reconstruction served as reference in all individuals. Subgroup analysis was performed in 17 patients who received both, prospectively and retrospectively gated contrast enhanced scans (n = 8 with aortic valve calcifications). VNI images with prospective/retrospective gating had an overall sensitivity of 69.2%/56.0%, specificity of 100%/100%, accuracy of 85.4%/81.0%, positive predictive value of 100%/100%, and a negative predictive value of 78.2%/75.0%. VNI images with retrospective gating achieved similar results. For both gating approaches, AVCS VNI showed high correlation (r = 0.983, P  < 0.001 for prospective; r = 0.986, P  < 0.001 for retrospective) with AVCS TNC . Subgroup analyses demonstrated excellent intra-individual correlation between different acquisition modes (r = 0.986, P  < 0.001). Thus, VNI images derived from cardiac PCD-CT allow for excellent diagnostic performance in the assessment of AVCS, suggesting potential for the omission of true non-contrast scans in the clinical workup of patients with aortic calcifications.
Magnetic Particle Imaging meets Computed Tomography: first simultaneous imaging
Magnetic Particle Imaging (MPI) is a promising new tomographic modality for fast as well as three-dimensional visualization of magnetic material. For anatomical or structural information an additional imaging modality such as computed tomography (CT) is required. In this paper, the first hybrid MPI-CT scanner for multimodal imaging providing simultaneous data acquisition is presented.
Effects of image homogeneity on stenosis visualization at 7 T in a coronary artery phantom study: With and without B1-shimming and parallel transmission
Background To investigate the effects of B1-shimming and radiofrequency (RF) parallel transmission (pTX) on the visualization and quantification of the degree of stenosis in a coronary artery phantom using 7 Tesla (7 T) magnetic resonance imaging (MRI). Methods Stenosis phantoms with different grades of stenosis (0%, 20%, 40%, 60%, 80%, and 100%; 5 mm inner vessel diameter) were produced using 3D printing (clear resin). Phantoms were imaged with four different concentrations of diluted Gd-DOTA representing established arterial concentrations after intravenous injection in humans. Samples were centrally positioned in a thorax phantom of 30 cm diameter filled with a custom-made liquid featuring dielectric properties of muscle tissue. MRI was performed on a 7 T whole-body system. 2D-gradient-echo sequences were acquired with an 8-channel transmit 16-channel receive (8 Tx / 16 Rx) cardiac array prototype coil with and without pTX mode. Measurements were compared to those obtained with identical scan parameters using a commercially available 1 Tx / 16 Rx single transmit coil (sTX). To assess reproducibility, measurements (n = 15) were repeated at different horizontal angles with respect to the B0-field. Results B1-shimming and pTX markedly improved flip angle homogeneity across the thorax phantom yielding a distinctly increased signal-to-noise ratio (SNR) averaged over a whole slice relative to non-manipulated RF fields. Images without B1-shimming showed shading artifacts due to local B1+-field inhomogeneities, which hampered stenosis quantification in severe cases. In contrast, B1-shimming and pTX provided superior image homogeneity. Compared with a conventional sTX coil higher grade stenoses (60% and 80%) were graded significantly (p<0.01) more precise. Mild to moderate grade stenoses did not show significant differences. Overall, SNR was distinctly higher with B1-shimming and pTX than with the conventional sTX coil (inside the stenosis phantoms 14%, outside the phantoms 32%). Both full and half concentration (10.2 mM and 5.1 mM) of a conventional Gd-DOTA dose for humans were equally suitable for stenosis evaluation in this phantom study. Conclusions B1-shimming and pTX at 7 T can distinctly improve image homogeneity and therefore provide considerably more accurate MR image analysis, which is beneficial for imaging of small vessel structures.