Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
20 result(s) for "Bori, Guillem"
Sort by:
Experiences during Switching from Two-Stage to One-Stage Revision Arthroplasty for Chronic Total Knee Arthroplasty Infection
The objective of this study was to evaluate our preliminary results after changing our surgical strategy from 2-stage revision arthroplasty to 1-stage revision arthroplasty for patients with chronic knee periprosthetic joint infection. We conducted a prospective study of knee arthroplasty patients that had been diagnosed with chronic infection and treated using a 1-stage revision regardless of the traditional criteria applied for indication thereof. We evaluated two main variables: infection control and economic costs. The definitive diagnosis of infection of the revision was determined by using the criteria proposed by the Musculoskeletal Infection Society. The costs were calculated as average costs in USD, as described by Srivastava (2019), for 1-stage or 2-stage revisions. Eighteen patients were included in the study, and infection was controlled in 17 patients. The total economic savings for our hospital from these 18 patients amounted to USD 291,152. This clinical success has led to major changes in how our hospital approaches the treatment of chronically infected knee replacements, in addition to substantial economic advantages for the hospital.
One-Stage Hip Revision Arthroplasty Using Megaprosthesis in Severe Bone Loss of The Proximal Femur Due to Radiological Diffuse Osteomyelitis
Managing substantial proximal and/or distal femoral bone defects is one of the biggest challenges in chronic hip periprosthetic joint infection. Most authors use two-stage arthroplasty with a temporary antibiotic-loaded cement spacer for the management of these patients. In this study, we show our experience with one-stage exchange arthroplasty in managing severe bone defects due to radiological-extensive proximal femoral osteomyelitis. Two patients were included in the study. They showed radiological-extensive proximal femoral osteomyelitis, and they were treated with one-stage exchange arthroplasty using megaprosthesis. Diffuse osteomyelitis was confirmed in both cases; in one case, the histology was compatible with osteomyelitis, and the other case had a positive culture identified in a bone sample. At a minimum of a four-year follow-up, the patients did not reveal any clinical, radiological or laboratory signs of infection. In conclusion, one-stage exchange arthroplasty and megaprosthesis is an option for the treatment of chronic hip periprosthetic joint infection associated with radiological-diffuse proximal femoral osteomyelitis.
Traumatic Atlanto-Occipital Dislocation: A Case Report
We report a 30-year-old man with atlanto-occipital dislocation after a traffic accident. Diagnosis was based on radiography, computed tomography, and magnetic resonance imaging. Owing to the critical conditions that did not fulfil advanced trauma and life support protocols, surgical treatment was deferred, and the patient died 10 hours later.
Fracture of Ceramic Liner and Head in a Total Hip Arthroplasty with a Sandwich Type Cup
Due to its advantages, ceramic-on-ceramic bearings have been widely used in young patients for almost 30 years. Long-term survivorship, low wear, and low biological reactivity to particles are some of its characteristics. Even though this material has had a lot of improvements, the risk of fracture is one of the concerns. There have been reports of fracture of ceramic in the acetabular liner and head but no fractures of both in the same patient. We report a case of a fracture in a sandwich type acetabular liner and the ceramic head in a patient involving ankylosing spondylitis. It occurred three years after the operation and with no history of direct trauma. We decided to change the bearing surfaces to metal polyethylene without removing the metal back. The patient is satisfied by the clinical results after a 5-year followup.
One-stage hip revision arthroplasty using megaprosthesis in severe bone loss of the proximal femur due to radiological diffuse osteomyelitis
Managing substantial proximal and/or distal femoral bone defects is one of the biggest challenges in chronic hip periprosthetic joint infection. Most authors use two-stage arthroplasty with a temporary antibiotic-loaded cement spacer for the management of these patients. In this study, we show our experience with one-stage exchange arthroplasty in managing severe bone defects due to radiological-extensive proximal femoral osteomyelitis. Two patients were included in the study. They showed radiological-extensive proximal femoral osteomyelitis, and they were treated with one-stage exchange arthroplasty using megaprosthesis. Diffuse osteomyelitis was confirmed in both cases; in one case, the histology was compatible with osteomyelitis, and the other case had a positive culture identified in a bone sample. At a minimum of a four-year follow-up, the patients did not reveal any clinical, radiological or laboratory signs of infection. In conclusion, one-stage exchange arthroplasty and megaprosthesis is an option for the treatment of chronic hip periprosthetic joint infection associated with radiological-diffuse proximal femoral osteomyelitis.
Assessment of Patients with a DePuy ASR Metal-on-Metal Hip Replacement: Results of Applying the Guidelines of the Spanish Society of Hip Surgery in a Tertiary Referral Hospital
The prognosis associated with the DePuy ASR hip cup is poor and varies according to the series. This implant was withdrawn from use in 2010 and all patients needed to be assessed. We present the results of the assessment of our patients treated with this device, according to the Spanish Society of Hip Surgery (SECCA) algorithm published in 2011. This retrospective study evaluates 83 consecutive ASR cups, followed up at a mean of 2.9 years. Serum levels of chromium and cobalt, as well as the acetabular abduction angle, were determined in order to assess their possible correlation with failure, defined as the need for revision surgery. The mean Harris Hip Score was 83.2 (range 42–97). Eight arthroplasties (13.3%) required revision due to persistent pain and/or elevated serum levels of chromium/cobalt. All the cups had a correct abduction angle, and there was no correlation between elevated serum levels of metal ions and implant failure. Since two previous ASR implants were exchanged previously to the recall, the revision rate for ASR cups in our centre is 18.2% at 2.9 years.
One- and two-stage surgical revision of peri-prosthetic joint infection of the hip: a pooled individual participant data analysis of 44 cohort studies
One-stage and two-stage revision strategies are the two main options for treating established chronic peri-prosthetic joint infection (PJI) of the hip; however, there is uncertainty regarding which is the best treatment option. We aimed to compare the risk of re-infection between the two revision strategies using pooled individual participant data (IPD). Observational cohort studies with PJI of the hip treated exclusively by one- or two-stage revision and reporting re-infection outcomes were retrieved by searching MEDLINE, EMBASE, Web of Science, The Cochrane Library, and the WHO International Clinical Trials Registry Platform; as well as email contact with investigators. We analysed IPD of 1856 participants with PJI of the hip from 44 cohorts across four continents. The primary outcome was re-infection (recurrence of infection by the same organism(s) and/or re-infection with a new organism(s)). Hazard ratios (HRs) for re-infection were calculated using Cox proportional frailty hazards models. After a median follow-up of 3.7 years, 222 re-infections were recorded. Reinfection rates per 1000 person-years of follow-up were 16.8 (95% CI 13.6-20.7) and 32.3 (95% CI 27.3-38.3) for onestage and two-stage strategies respectively. The age- and sex-adjusted HR of re-infection for two-stage revision was 1.70 (0.58-5.00) when compared with one-stage revision. The association remained consistently absent after further adjustment for potential confounders. The HRs did not vary importantly in clinically relevant subgroups. Analysis of pooled individual patient data suggest that a one-stage revision strategy may be as effective as a two-stage revision strategy in treating PJI of the hip.
Septic arthritis of the hip caused by nontyphi Salmonella after urinary tract infection
On admission, the patient's axillary temperature was 37.9°C. Laboratory studies indicated a white blood cell count (WBC) of 18 660/mm3 (75.4% neutrophils and 11.8% lymphocytes), a C-reactive protein level of 11.4 mg/L and an erythrocyte sedimentation rate of 96 mm/h. Magnetic resonance imaging of the pelvis revealed inflammatory signs and effusion of the right hip as well as degenerative changes indicative of early osteonecrosis of both hips (Fig. 2). After 3 months without any sign of infection, the spacer was removed and a noncemented total hip prosthesis (Echelon 14/190, Reflection 56, XL-PE, long neck +4, Cr-Co head) (Smith & Nephew, Memphis, TN) was implanted (Fig. 3).
Interface membrane is the best sample for histological study to diagnose prosthetic joint infection
The objective of our study was to study which is the most accurate specimen for histological diagnosis of prosthetic joint infections (pseudocapsule or interface membrane). This is a prospective study including hip revision arthroplasties performed from January 2007 to June 2009. Specimens from pseudocapsule and from interface membrane were obtained from each patient. The histology was considered positive for infection when ≥5 neutrophils per high-power field ( × 40) were found. Definitive diagnosis of infection was considered when ≥2 cultures were positive for the same microorganism. According to the definition of infection, patients were classified in two groups: (A) patients with aseptic loosening in whom cultures obtained during surgery were negative and (B) patients with prosthetic joint infection. A total of 69 revisions were included in the study; 57 were classified in group A and 12 in group B. In group B, the percentage of positive interface membrane histology was significantly higher than the percentage of positive pseudocapsule histology (83 vs 42%, P =0.04, Fisher's exact test). The results suggest that periprosthetic interface membrane is the best specimen for the histological diagnosis of prosthetic joint infection.
Early clinical and radiological outcomes for the Taperloc Complete Microplasty stem
The use of short stem designs in total hip arthroplasty is not a new concept, but its popularity has increased as a bone-sparing alternative to traditional stems. This study analyzed the midterm clinical and radiological results of the Taperloc Complete Microplasty stem (Zimmer Biomet® Warsaw, IN, USA). A total of 32 patients (20 men and 12 women) were retrospectively documented and received 40 stems (eight bilateral). The median patient age was 50 years (interquartile range 43–58) at the time of surgery. The median follow-up was 36.5 months (interquartile range 26.75–50.25). Indication for total hip arthroplasty was osteoarthritis (62.5% of patients), avascular necrosis (25%), and developmental dysplasia of the hip (12.5%). The Merle d’Aubigné score improved from a mean 11.5 preoperatively to a mean 17.5 at the latest follow-up. During X-ray assessment, we observed one subsidence of the stem (3 mm) and four cases of varus malalignment without clinical consequences. No cases of osteolysis were reported, and no stems were revised. According to our results, this short tapered stem shows a good early-term outcome. Prospective results and a longer follow-up are needed to assess the long-term survival of this stem fully.