Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
154
result(s) for
"Brandl, Andreas"
Sort by:
Assessing reliability and validity of different stiffness measurement tools on a multi-layered phantom tissue model
by
Bartsch, Katja
,
Weber, Patrick
,
Bauermeister, Wolfgang
in
692/308/2778
,
692/698/1671/1668/1973
,
Bioengineering
2023
Changes in the mechanical properties (i.e., stiffness) of soft tissues have been linked to musculoskeletal disorders, pain conditions, and cancer biology, leading to a rising demand for diagnostic methods. Despite the general availability of different stiffness measurement tools, it is unclear as to which are best suited for different tissue types and the related measurement depths. The study aimed to compare different stiffness measurement tools’ (SMT) reliability on a multi-layered phantom tissue model (MPTM). A polyurethane MPTM simulated the four layers of the thoracolumbar region: cutis (CUT), subcutaneous connective tissue (SCT), fascia profunda (FPR), and erector spinae (ERS), with varying stiffness parameters. Evaluated stiffness measurement tools included Shore Durometer, Semi-Electronic Tissue Compliance Meter (STCM), IndentoPRO, MyotonPRO, and ultrasound imaging. Measurements were made by two independent, blinded examiners. Shore Durometer, STCM, IndentoPRO, and MyotonPRO reliably detected stiffness changes in three of the four MPTM layers, but not in the thin (1 mm thick) layer simulating FPR. With ultrasound imaging, only stiffness changes in layers thicker than 3 mm could be measured reliably. Significant correlations ranging from 0.70 to 0.98 (all
p
< 0.01) were found. The interrater reliability ranged from good to excellent (ICC(2,2) = 0.75–0.98). The results are encouraging for researchers and clinical practitioners as the investigated stiffness measurement tools are easy-to-use and comparatively affordable.
Journal Article
Influence of high-energy laser therapy to the patellar tendon on its ligamentous microcirculation: An experimental intervention study
by
Brandl, Andreas
,
Lingenfelder, Christian
,
Schleip, Robert
in
Achilles Tendon
,
Biology and Life Sciences
,
Blood
2023
Laser therapeutic applications, such as the use of high energy lasers (HILT), are widely used in physical therapy, but basic studies on the mechanisms of action of HILT on tendinous/ligamentous tissue are largely lacking. The aim of this study was to investigate microcirculatory changes of the patellar tendon by HILT. 21 healthy volunteers were included in the present investigation. Before and after HILT, as well as 10 minutes later, the microcirculation was measured by noninvasive laser Doppler and white light spectroscopy (O2C device). Tissue temperature was recorded at the measurement time points using thermography. Blood flow increased significantly by 86.38 arbitrary units (AU; p < 0.001) after the intervention and by 25.76 AU (p < 0.001) at follow-up. Oxygen saturation increased by 20.14% (p < 0.001) and 13.48%, respectively (p < 0.001), whereas relative hemoglobin decreased by 6.67 AU and 7.90 AU, respectively. Tendon temperature increased by 9.45° and 1.94° Celsius, respectively. Acceleration of blood flow by improving the flow properties of erythrocytes and platelets may have caused the results. HILT could be a therapeutic perspective for tendon pathologies with impaired microcirculation, although further studies are needed to validate the experimental results.
Journal Article
Ground truth and demographic data for ultrasound assessment of thoracolumbar fascia deformation and shearing
2025
Restricted mobility and/or deformability of the thoracolumbar fascia (TLF) could be a diagnostic criterion or a risk factor for the development of low back pain. Therefore, ultrasound measurement techniques to quantify TLF characteristics have been used for over two decades without comprehensive validation. The aim of this paper is to present data to validate ultrasound methods for the assessment of shear, sliding motion and deformation based on distance measurement of anatomical landmarks or speckle tracking. In addition, epidemiological data with deformation values of the TLF are offered. A sliding device with polyurethane tissue phantoms was developed to generate ground truth values for different distances and velocities. The resulting dataset includes 36 ultrasound videos for typical TLF sliding distances of 3–20 mm, 10 videos for various velocities between 2.4 and 5.4 mm/s, demographic data on TLF deformation from 199 individuals, and a MATLAB example script for use with image processing software. For the first time, the dataset provides researchers with ground truth values to validate their ultrasound methods.
Journal Article
Quantifying thoracolumbar fascia deformation to discriminate acute low back pain patients and healthy individuals using ultrasound
2024
Reduced shear strain and deformability of the thoracolumbar fascia has been linked to low back pain. A number of ultrasound examination methods have been developed for laboratory rather than clinical practice. The aim of this study was to examine the reliability and discriminative validity (patients vs. healthy individuals) of an ultrasound (US) measurement method for the quantification of thoracolumbar fascia deformation (TLFD). A cross-sectional study with US assessment and rater blinding was conducted in a manual therapy clinic and a university laboratory. 16 acute low back pain (aLBP) patients and 15 healthy individuals performed a standardized trunk extension task. US measurements of TLFD were carried out independently by two raters by imaging the TLF in the starting and ending positions of the movement. Intra-rater and inter-rater reliability were calculated using intraclass correlation coefficients (ICCs) and minimal detectable changes (MDC) were calculated. Receiver operating characteristic (ROC) curve analysis was used to determine the cut-off for TLFD to discriminate the study groups. Kappa statistics were performed to assess rater agreement in discrimination. Intra-rater reliability was excellent (ICC: .92, MDC: 5.54 mm,
p
< .001) and inter-rater reliability was good (ICC: .78, MDC: 8.70 mm,
p
< .001). The cut-off for TLFD was 6 mm with a sensitivity of 100% and a specificity of 93.75% and the raters agreed moderately (κ = 0.74,
p
< .001) when distinguishing patients and controls. The reliability of the US method for assessing TLFD is moderate to excellent, and the ability to discriminate aLBP patients from healthy individuals is moderate. The method could be used to capture an additional parameter in morphological aLBP screenings.
Journal Article
Reliability and validity of an app-assisted tissue compliance meter in measuring tissue stiffness on a phantom model
by
Bartsch, Katja
,
Brandl, Andreas
,
Acikalin, Eda
in
Biomechanics
,
Correlation analysis
,
Drugs and Devices
2024
Most methods for soft tissue stiffness assessment require high financial resources, significant technical effort, or extensive therapist training. The PACT Sense device was developed to be used in a wide range of applications and user groups. However, to date, there are no data on its validity and reliability. The aim of this study was to investigate the validity and reliability of the PACT device.
A polyurethane phantom tissue model (PTM) mimicking the mechanical properties of the fascia profunda and the erector spinae muscle was used. Stiffness measurements with PACT were conducted by two independent investigators. For construct validity, correlations were calculated between the known stiffness of the PTM and values obtained with PACT. For concurrent validity, we determined the association between the PACT values and additional measurements with the established MyotonPRO device. To estimate interrater and intrarater (two measurements with an interval of 7 days) reliability, we used the intraclass correlation coefficient (ICC).
Correlation analysis (PTM/PACT) revealed very high concurrent validity (r = 0.99;
< 0.001), construct validity (PACT/MyotonPRO) was 0.87,
< 0.001. Both, interrater reliability (ICC = 0.85;
= 0.036) and intrarater reliability were good (ICC = 0.89;
< 0.001).
The PACT provides valid and reliable stiffness measurements in tissue phantoms. Further studies in humans are needed to confirm its physiometric properties under
conditions.
Journal Article
Relations between daily stressful events, exertion, heart rate variability, and thoracolumbar fascia deformability: a case report
by
Brandl, Andreas
,
Schubert, Christian
,
Engel, Raimund
in
Analysis
,
Autonomic Nervous System - physiopathology
,
Backache
2024
Background
The posture of performance-oriented sport climbers adapts in a way that likely promotes the development of low back pain. The thoracolumbar fascia, while also contributing to performance, seems to be involved in that process. Furthermore, there has been evidence of the stiffening of the fascial structures in disorders associated with negative affectivity. The study aims to investigate the relationship between the autonomic nervous system and the deformability of the thoracolumbar fascia in a sport climber in a natural setting.
Case presentation
Over a 30 day period, a 50-year-old German male reported daily morning resting heart rate variability and daily inventory of stressful events. The thoracolumbar fascia deformation was measured daily using ultrasound in a manual therapy clinic. A time series analysis was performed to detect possible time-delayed relationships between the variables.
A cluster analyses revealed two distinguishable heart rate variability clusters (heart rate variability clusters 1 and 2). Both clusters were correlated with thoracolumbar fascia deformation and daily inventory of stressful events. Higher heart rate variability cluster 1 immediately caused lower thoracolumbar fascia deformation. Heart rate variability cluster 1 parameters mediated the effect of daily inventory of stressful events on a decrease in thoracolumbar fascia deformation with a 2-day delay. One heart rate variability cluster 2 parameter mediated the effect of daily inventory of stressful events on an increase in thoracolumbar fascia deformation with a 7-day delay.
Conclusion
Heart rate variability cluster 1 values, which probably indicate sympathetic nervous system activity, are directly related to thoracolumbar fascia. Presumably, the sympathetic nervous system mediated the effect of daily inventory of stressful events on a lower thoracolumbar fascia deformation with a 2-day delay, followed by a supercompensation, most likely parasympathetically mediated. Coaches and trainers should be aware of these mechanisms and consider monitoring during training to minimize potential additional risk factors for impaired performance and health.
Journal Article
Immediate Effects of Myofascial Release on the Thoracolumbar Fascia and Osteopathic Treatment for Acute Low Back Pain on Spine Shape Parameters: A Randomized, Placebo-Controlled Trial
2021
Background: Spine shape parameters, such as leg length and kyphotic or lordotic angle, are influenced by low back pain. There is also evidence that the thoracolumbar fascia plays a role in such pathologies. This study examined the immediate effects of a myofascial release (MFR) technique on the thoracolumbar fascia and of an osteopathic treatment (OMT) on postural parameters in patients with acute low back pain (aLBP). Methods: This study was a single-blind randomized placebo-controlled trial. Seventy-one subjects (43.8 ± 10.5 years) suffering from aLBP were randomly and blindedly assigned to three groups to be treated with MFR, OMT, or a placebo intervention. Spinal shape parameters (functional leg length discrepancy (fLLD), kyphotic angle, and lordotic angle) were measured before and after the intervention using video raster stereography. Results: Within the MFR group, fLLD reduced by 5.2 mm, p < 0.001 and kyphotic angle by 8.2 degrees, p < 0.001. Within the OMT group, fLLD reduced by 4.5 mm, p < 0.001, and kyphotic angle by 8.4°, p = 0.007. Conclusion: MFR and OMT have an influence on fLLD and the kyphotic angle in aLBP patients. The interventions could have a regulating effect on the impaired neuromotor control of the lumbar muscles.
Journal Article
Bioactive Copper-Doped Glass Scaffolds Can Stimulate Endothelial Cells in Co-Culture in Combination with Mesenchymal Stem Cells
by
Horch, Raymund E.
,
Gbureck, Uwe
,
Hoppe, Alexander
in
Alkaline phosphatase
,
Angiogenesis
,
Assaying
2014
Bioactive glass (BG) scaffolds are being investigated for bone tissue engineering applications because of their osteoconductive and angiogenic nature. However, to increase the in vivo performance of the scaffold, including enhancing the angiogenetic growth into the scaffolds, some researchers use different modifications of the scaffold including addition of inorganic ionic components to the basic BG composition. In this study, we investigated the in vitro biocompatibility and bioactivity of Cu2+-doped BG derived scaffolds in either BMSC (bone-marrow derived mesenchymal stem cells)-only culture or co-culture of BMSC and human dermal microvascular endothelial cells (HDMEC). In BMSC-only culture, cells were seeded either directly on the scaffolds (3D or direct culture) or were exposed to ionic dissolution products of the BG scaffolds, kept in permeable cell culture inserts (2D or indirect culture). Though we did not observe any direct osteoinduction of BMSCs by alkaline phosphatase (ALP) assay or by PCR, there was increased vascular endothelial growth factor (VEGF) expression, observed by PCR and ELISA assays. Additionally, the scaffolds showed no toxicity to BMSCs and there were healthy live cells found throughout the scaffold. To analyze further the reasons behind the increased VEGF expression and to exploit the benefits of the finding, we used the indirect method with HDMECs in culture plastic and Cu2+-doped BG scaffolds with or without BMSCs in cell culture inserts. There was clear observation of increased endothelial markers by both FACS analysis and acetylated LDL (acLDL) uptake assay. Only in presence of Cu2+-doped BG scaffolds with BMSCs, a high VEGF secretion was demonstrated by ELISA; and typical tubular structures were observed in culture plastics. We conclude that Cu2+-doped BG scaffolds release Cu2+, which in turn act on BMSCs to secrete VEGF. This result is of significance for the application of BG scaffolds in bone tissue engineering approaches.
Journal Article
Effect of osteopathic techniques on human resting muscle tone in healthy subjects using myotonometry: a factorial randomized trial
2022
Musculoskeletal disorders (MSDs) are highly prevalent, burdensome, and putatively associated with an altered human resting muscle tone (HRMT). Osteopathic manipulative treatment (OMT) is commonly and effectively applied to treat MSDs and reputedly influences the HRMT. Arguably, OMT may modulate alterations in HRMT underlying MSDs. However, there is sparse evidence even for the effect of OMT on HRMT in healthy subjects. A 3 × 3 factorial randomised trial was performed to investigate the effect of myofascial release (MRT), muscle energy (MET), and soft tissue techniques (STT) on the HRMT of the corrugator supercilii (CS), superficial masseter (SM), and upper trapezius muscles (UT) in healthy subjects in Hamburg, Germany. Participants were randomised into three groups (1:1:1 allocation ratio) receiving treatment, according to different muscle-technique pairings, over the course of three sessions with one-week washout periods. We assessed the effect of osteopathic techniques on muscle tone (F), biomechanical (S, D), and viscoelastic properties (R, C) from baseline to follow-up (primary objective) and tested if specific muscle-technique pairs modulate the effect pre- to post-intervention (secondary objective) using the MyotonPRO (at rest). Ancillary, we investigate if these putative effects may differ between the sexes. Data were analysed using descriptive (mean, standard deviation, and quantiles) and inductive statistics (Bayesian ANOVA). 59 healthy participants were randomised into three groups and two subjects dropped out from one group (n = 20; n = 20; n = 19–2). The CS produced frequent measurement errors and was excluded from analysis. OMT significantly changed F (−0.163 [0.060]; p = 0.008), S (−3.060 [1.563]; p = 0.048), R (0.594 [0.141]; p < 0.001), and C (0.038 [0.017]; p = 0.028) but not D (0.011 [0.017]; p = 0.527). The effect was not significantly modulated by muscle-technique pairings (p > 0.05). Subgroup analysis revealed a significant sex-specific difference for F from baseline to follow-up. No adverse events were reported. OMT modified the HRMT in healthy subjects which may inform future research on MSDs. In detail, MRT, MET, and STT reduced the muscle tone (F), decreased biomechanical (S not D), and increased viscoelastic properties (R and C) of the SM and UT (CS was not measurable). However, the effect on HRMT was not modulated by muscle–technique interaction and showed sex-specific differences only for F.
Trial registration
German Clinical Trial Register (DRKS00020393).
Journal Article
Fungal Peritonitis: Underestimated Disease in Critically Ill Patients with Liver Cirrhosis and Spontaneous Peritonitis
2016
Spontaneous peritonitis, especially spontaneous fungal peritonitis (SFP), is an important and potentially fatal complication in patients with endstage liver disaese. We evaluated potential risk factors, microbiological findings, and outcome of patients with SFP compared to spontaneous bacterial peritonitis (SBP) in critically ill patients.
Retrospective analyses of critically ill patients with suspected spontaneous peritonitis.
Out of 205 patients, 20 (10%) had SFP, 28 (14%) had SBP, 48 (24%) had peritonitis without microbiological findings (SP) and 109 (52%) had no-peritonitis (NP). APACHE II and SOFA score were significantly higher in patients with SFP (26; 22-28; p<0.004 and 16; 14-18; p<0.002), SBP (26; 22-28; p<0.004 and 16; 14-18; p<0.002) and SP (24; 18-30; p<0.045 and 14; 10-18; p<0.044) as compared to NP (22; 16-24 and 12; 10-14). CHILD Pugh classification was mainly CHILD C and MELD Score was in patients with SFP (34; 18-40; p<0.001), SBP (32;12-40 p<0.002) and SP (29; 14-40 p<0.003) significantly higher as compared to NP (25;8-40). Nosocomial peritonitis could be significantly more often found in patients with SFP (65%; p<0.023) and SBP (62%, p<0.030) as compared to SP (51 p = 0.243) and NP (45%). Antibiotic pretreatment last 3 month prior peritonitis was significantly more often in patients with SFP (85%; p<0.002), SBP (71%, p<0.033), and SP (56; p<0.040) as compared to NP (33%). Candida albicans (60%; 12/20) was the most common isolated fungus, followed by Candida glabrata (13%) and Candida krusei (13%). Mortality rate was significantly higher in patients with SFP (90%, p<0.001), followed by SBP (75%; p<0.001) and SP (69%; p<0.001) as compared to NP (45%).
SFP is not a rare complication in end stage liver disease which is associated with increased mortality. Physicians should be aware of SFP in patients with CHILD C liver cirrhosis, elevated MELD score, antibiotic pretreatment and nosocomial peritonitis.
Journal Article