Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
16 result(s) for "Bult, Wouter"
Sort by:
Tacrolimus Variability and Clinical Outcomes in the Early Post-lung Transplantation Period: Oral Versus Continuous Intravenous Administration
Background and Objective High variability in tacrolimus pharmacokinetics directly after lung transplantation (LuTx) may increase the risk for acute kidney injury (AKI) and transplant rejection. The primary objective was to compare pharmacokinetic variability in patients receiving tacrolimus orally versus intravenously early after LuTx. Methods Pharmacokinetic and clinical data from 522 LuTx patients transplanted between 2010 and 2020 in two university hospitals were collected to compare orally administered tacrolimus to intravenous tacrolimus early post-transplantation. Tacrolimus blood concentration variability, measured as intrapatient variability (IPV%) and  percentage of time within the therapeutic range (TTR%), was analyzed within the first 14 days after LuTx. Secondary outcomes were AKI, acute rejection, length of stay in the intensive care unit (ICU), and mortality in the ICU and during hospital admission. Results We included 224 patients in the oral and 298 in the intravenous group. The mean adjusted IPV% was 10.8% (95% confidence interval [CI] 6.9–14.6; p < 0.001) higher in the oral group (27.2%) than the intravenous group (16.4%). The mean TTR% was 7.3% (95% CI − 11.3 to − 3.4; p < 0.001) lower in the oral group (39.6%) than in the intravenous group (46.9%). The incidence of AKI was 46.0% for oral and 42.6% for intravenous administration (adjusted odds ratio [OR] 1.2; 95% CI 0.8–1.8; p = 0.451). The frequencies of clinically diagnosed acute rejection in the oral and intravenous groups were nonsignificant (24.6% vs 17.8%; OR 1.5 [95% CI 1.0–2.3; p = 0.059]). ICU and hospital mortality rate and ICU length of stay were similar. Conclusions Administering tacrolimus orally directly after LuTx leads to a higher variability in blood concentrations compared to intravenous administration. There was no difference in the occurrence of AKI or transplant rejection.
Towards more efficient use of intravenous lumens in multi-infusion settings: development and evaluation of a multiplex infusion scheduling algorithm
Background Multi-drug intravenous (IV) therapy is one of the most common medical procedures used in intensive care units (ICUs), operating rooms, oncology wards and many other hospital departments worldwide. As drugs or their solvents are frequently chemically incompatible, many solutions must be administered through separate lumens. When the number of available lumens is too low to facilitate the safe administration of these solutions, additional (peripheral) IV catheters are often required, causing physical discomfort and increasing the risk for catheter related complications. Our objective was to develop and evaluate an algorithm designed to reduce the number of intravenous lumens required in multi-infusion settings by multiplexing the administration of various parenteral drugs and solutions. Methods A multiplex algorithm was developed that schedules the alternating IV administration of multiple incompatible IV solutions through a single lumen, taking compatibility-related, pharmacokinetic and pharmacodynamic constraints of the relevant drugs into account. The conventional scheduling procedure executed by ICU nurses was used for comparison. The number of lumens required by the conventional procedure (L CONV ) and multiplex algorithm (L MX ) were compared. Results We used data from 175,993 ICU drug combinations, with 2251 unique combinations received by 2715 consecutive ICU patients. The mean ± SD number of simultaneous IV solutions was 2.8 ± 1.6. In 27% of all drug combinations, and 61% of the unique combinations the multiplex algorithm required fewer lumens ( p  < 0.001). With increasing L CONV , the reduction in number of lumens by the multiplex algorithm further increased ( p  < 0.001). In only 1% of cases multiplexing required > 3 lm, versus 12% using the conventional procedure. Conclusion The multiplex algorithm addresses a major issue that occurs in ICUs, operating rooms, oncology wards, and many other hospital departments where several incompatible drugs are infused through a restricted number of lumens. The multiplex algorithm allows for more efficient use of IV lumens compared to the conventional multi-infusion strategy.
Improved usability of a multi-infusion setup using a centralized control interface: A task-based usability test
The objective of this study was to assess the usability benefits of adding a bedside central control interface that controls all intravenous (IV) infusion pumps compared to the conventional individual control of multiple infusion pumps. Eighteen dedicated ICU nurses volunteered in a between-subjects task-based usability test. A newly developed central control interface was compared to conventional control of multiple infusion pumps in a simulated ICU setting. Task execution time, clicks, errors and questionnaire responses were evaluated. Overall the central control interface outperformed the conventional control in terms of fewer user actions (40±3 vs. 73±20 clicks, p<0.001) and fewer user errors (1±1 vs. 3±2 errors, p<0.05), with no difference in task execution times (421±108 vs. 406±119 seconds, not significant). Questionnaires indicated a significant preference for the central control interface. Despite being novice users of the central control interface, ICU nurses displayed improved performance with the central control interface compared to the conventional interface they were familiar with. We conclude that the new user interface has an overall better usability than the conventional interface.
Intratumoral Administration of Holmium-166 Acetylacetonate Microspheres: Antitumor Efficacy and Feasibility of Multimodality Imaging in Renal Cancer
The increasing incidence of small renal tumors in an aging population with comorbidities has stimulated the development of minimally invasive treatments. This study aimed to assess the efficacy and demonstrate feasibility of multimodality imaging of intratumoral administration of holmium-166 microspheres ((166)HoAcAcMS). This new technique locally ablates renal tumors through high-energy beta particles, while the gamma rays allow for nuclear imaging and the paramagnetism of holmium allows for MRI. (166)HoAcAcMS were administered intratumorally in orthotopic renal tumors (Balb/C mice). Post administration CT, SPECT and MRI was performed. At several time points (2 h, 1, 2, 3, 7 and 14 days) after MS administration, tumors were measured and histologically analyzed. Holmium accumulation in organs was measured using inductively coupled plasma mass spectrometry. (166)HoAcAcMS were successfully administered to tumor bearing mice. A striking near-complete tumor-control was observed in (166)HoAcAcMS treated mice (0.10±0.01 cm(3) vs. 4.15±0.3 cm(3) for control tumors). Focal necrosis and inflammation was present from 24 h following treatment. Renal parenchyma outside the radiated region showed no histological alterations. Post administration CT, MRI and SPECT imaging revealed clear deposits of (166)HoAcAcMS in the kidney. Intratumorally administered (166)HoAcAcMS has great potential as a new local treatment of renal tumors for surgically unfit patients. In addition to strong cancer control, it provides powerful multimodality imaging opportunities.
Holmium-166 radioembolization for the treatment of patients with liver metastases: design of the phase I HEPAR trial
Background Intra-arterial radioembolization with yttrium-90 microspheres ( 90 Y-RE) is an increasingly used therapy for patients with unresectable liver malignancies. Over the last decade, radioactive holmium-166 poly(L-lactic acid) microspheres ( 166 Ho-PLLA-MS) have been developed as a possible alternative to 90 Y-RE. Next to high-energy beta-radiation, 166 Ho also emits gamma-radiation, which allows for imaging by gamma scintigraphy. In addition, Ho is a highly paramagnetic element and can therefore be visualized by MRI. These imaging modalities are useful for assessment of the biodistribution, and allow dosimetry through quantitative analysis of the scintigraphic and MR images. Previous studies have demonstrated the safety of 166 Ho-PLLA-MS radioembolization ( 166 Ho-RE) in animals. The aim of this phase I trial is to assess the safety and toxicity profile of 166 Ho-RE in patients with liver metastases. Methods The HEPAR study (Holmium Embolization Particles for Arterial Radiotherapy) is a non-randomized, open label, safety study. We aim to include 15 to 24 patients with liver metastases of any origin, who have chemotherapy-refractory disease and who are not amenable to surgical resection. Prior to treatment, in addition to the standard technetium-99m labelled macroaggregated albumin ( 99m Tc-MAA) dose, a low radioactive safety dose of 60-mg 166 Ho-PLLA-MS will be administered. Patients are treated in 4 cohorts of 3-6 patients, according to a standard dose escalation protocol (20 Gy, 40 Gy, 60 Gy, and 80 Gy, respectively). The primary objective will be to establish the maximum tolerated radiation dose of 166 Ho-PLLA-MS. Secondary objectives are to assess tumour response, biodistribution, performance status, quality of life, and to compare the 166 Ho-PLLA-MS safety dose and the 99m Tc-MAA dose distributions with respect to the ability to accurately predict microsphere distribution. Discussion This will be the first clinical study on 166 Ho-RE. Based on preclinical studies, it is expected that 166 Ho-RE has a safety and toxicity profile comparable to that of 90 Y-RE. The biochemical and radionuclide characteristics of 166 Ho-PLLA-MS that enable accurate dosimetry calculations and biodistribution assessment may however improve the overall safety of the procedure. Trial registration ClinicalTrials.gov NCT01031784
Polymeric Micelles in Anticancer Therapy: Targeting, Imaging and Triggered Release
Micelles are colloidal particles with a size around 5-100 nm which are currently under investigation as carriers for hydrophobic drugs in anticancer therapy. Currently, five micellar formulations for anticancer therapy are under clinical evaluation, of which Genexol-PM has been FDA approved for use in patients with breast cancer. Micelle-based drug delivery, however, can be improved in different ways. Targeting ligands can be attached to the micelles which specifically recognize and bind to receptors overexpressed in tumor cells, and chelation or incorporation of imaging moieties enables tracking micelles in vivo for biodistribution studies. Moreover, pH-, thermo-, ultrasound-, or light-sensitive block copolymers allow for controlled micelle dissociation and triggered drug release. The combination of these approaches will further improve specificity and efficacy of micelle-based drug delivery and brings the development of a ‘magic bullet' a major step forward.
The effect of computerised decision support alerts tailored to intensive care on the administration of high-risk drug combinations, and their monitoring: a cluster randomised stepped-wedge trial
Drug–drug interactions (DDIs) can harm patients admitted to the intensive care unit (ICU). Yet, clinical decision support systems (CDSSs) aimed at helping physicians prevent DDIs are plagued by low-yield alerts, causing alert fatigue and compromising patient safety. The aim of this multicentre study was to evaluate the effect of tailoring potential DDI alerts to the ICU setting on the frequency of administered high-risk drug combinations. We implemented a cluster randomised stepped-wedge trial in nine ICUs in the Netherlands. Five ICUs already used potential DDI alerts. Patients aged 18 years or older admitted to the ICU with at least two drugs administered were included. Our intervention was an adapted CDSS, only providing alerts for potential DDIs considered as high risk. The intervention was delivered at the ICU level and targeted physicians. We hypothesised that showing only relevant alerts would improve CDSS effectiveness and lead to a decreased number of administered high-risk drug combinations. The order in which the intervention was implemented in the ICUs was randomised by an independent researcher. The primary outcome was the number of administered high-risk drug combinations per 1000 drug administrations per patient and was assessed in all included patients. This trial was registered in the Netherlands Trial Register (identifier NL6762) on Nov 26, 2018, and is now closed. In total, 10 423 patients admitted to the ICU between Sept 1, 2018, and Sept 1, 2019, were assessed and 9887 patients were included. The mean number of administered high-risk drug combinations per 1000 drug administrations per patient was 26·2 (SD 53·4) in the intervention group (n=5534), compared with 35·6 (65·0) in the control group (n=4353). Tailoring potential DDI alerts to the ICU led to a 12% decrease (95% CI 5–18%; p=0·0008) in the number of administered high-risk drug combinations per 1000 drug administrations per patient, after adjusting for clustering and prognostic factors. This cluster randomised stepped-wedge trial showed that tailoring potential DDI alerts to the ICU setting significantly reduced the number of administered high-risk drug combinations. Our list of high-risk drug combinations can be used in other ICUs, and our strategy of tailoring alerts based on clinical relevance could be applied to other clinical settings. ZonMw.
Low Dose Low-Molecular-Weight Heparin for Thrombosis Prophylaxis: Systematic Review with Meta-Analysis and Trial Sequential Analysis
International guidelines recommend low-molecular-weight heparin (LMWH) as first-line pharmacological option for the prevention of venous thromboembolism (VTE) in many patient categories. Guidance on the optimal prophylactic dose is lacking. We conducted a systematic review with meta-analysis and trial sequential analysis (TSA) of randomized controlled trials to assess benefits and harms of low-dose LMWH versus placebo or no treatment for thrombosis prophylaxis in patients at risk of VTE. PubMed, Cochrane Library, Web of Science, and Embase were searched up to June 2019. Results were presented as relative risk (RR) with conventional and TSA-adjusted confidence intervals (CI). Forty-four trials with a total of 22,579 participants were included. Six (14%) had overall low risk of bias. Low-dose LMWH was not statistically significantly associated with all-cause mortality (RR 0.99; 95%CI 0.85–1.14; TSA-adjusted CI 0.89–1.16) but did reduce symptomatic VTE (RR 0.62; 95%CI 0.48–0.81; TSA-adjusted CI 0.44–0.89) and any VTE (RR 0.61; 95%CI 0.50–0.75; TSA-adjusted CI 0.49–0.82). Analyses on major bleeding (RR 1.07; 95%CI 0.72–1.59), as well as serious adverse events (SAE) and clinically relevant non-major bleeding were inconclusive. There was very low to moderate-quality evidence that low-dose LMWH for thrombosis prophylaxis did not decrease all-cause mortality but reduced the incidence of symptomatic and asymptomatic VTE, while the analysis of the effects on bleeding and adverse events remained inconclusive.
In vitro evaluation of an intravenous microdialysis catheter for therapeutic drug monitoring of gentamicin and vancomycin
A central venous catheter with a built‐in microdialysis membrane is available for continuous lactate and glucose monitoring in the intensive care unit (ICU). As this catheter might also be suitable for repeated measurements of unbound drug levels, we studied in vitro the feasibility of monitoring unbound antibiotic concentrations. The catheter was placed in various media at 37°C spiked with gentamicin or vancomycin. Dialysate fractions were repeatedly collected over 3 hours with a NaCl 0.9% perfusate flow of 5 μL/min. Total and unbound drug concentrations in medium and perfusate were measured by immunoassay. After 60 minutes stable recovery for both drugs was observed, with mean ±SD relative recoveries of vancomycin and gentamicin in human serum of 64% ±0.4% and 73% ±3%. The recoveries of the unbound concentrations were 91% ±3% and 91% ±4%. This intravenous microdialysis system may be a very useful platform for therapeutic drug monitoring in the ICU.
Radioactive Holmium Acetylacetonate Microspheres for Interstitial Microbrachytherapy: An In Vitro and In Vivo Stability Study
ABSTRACT Purpose The clinical application of holmium acetylacetonate microspheres (HoAcAcMS) for the intratumoral radionuclide treatment of solid malignancies requires a thorough understanding of their stability. Therefore, an in vitro and an in vivo stability study with HoAcAcMS was conducted. Methods HoAcAcMS, before and after neutron irradiation, were incubated in a phosphate buffer at 37°C for 6 months. The in vitro release of holmium in this buffer after 6 months was 0.5%. Elemental analysis, scanning electron microscopy, infrared spectroscopy and time of flight secondary ion mass spectrometry were performed on the HoAcAcMS. Results After 4 days in buffer the acetylacetonate ligands were replaced by phosphate, without altering the particle size and surface morphology. HoAcAcMS before and after neutron irradiation were administered intratumorally in VX2 tumor-bearing rabbits. No holmium was detected in the faeces, urine, femur and blood. Histological examination of the tumor revealed clusters of intact microspheres amidst necrotic tissue after 30 days. Conclusion HoAcAcMS are stable both in vitro and in vivo and are suitable for intratumoral radionuclide treatment.