Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Reading Level
      Reading Level
      Clear All
      Reading Level
  • Content Type
      Content Type
      Clear All
      Content Type
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Item Type
    • Is Full-Text Available
    • Subject
    • Publisher
    • Source
    • Donor
    • Language
    • Place of Publication
    • Contributors
    • Location
11 result(s) for "Cantor, Abigail F"
Sort by:
Importance of pipe deposits to Lead and Copper Rule compliance
When Madison, Wis., exceeded the lead action level in 1992, residential and off-line tests suggested that lead release into the water was more complex than a lead solubility mechanism. Scale analyses (color and texture as well as mineralogical and elemental composition) of five excavated lead service lines (LSLs) revealed that accumulation of manganese (and iron) onto pipe walls had implications for lead corrosion by providing a high-capacity sink for lead. Manganese that accumulated from source well water onto pipe scales (up to 10% by weight of scale composition) served to capture and eventually transport lead to consumer taps. In addition, manganese sometimes obstructed the predominance of an insoluble (and thus potentially protective) plattnerite [Pb(IV) solid] scale layer. Full LSL replacement in Madison achieved Lead and Copper Rule compliance and a major reduction in lead contamination and exposure, supplemented by unidirectional flushing of water mains and manganese control in the source well water.
Diagnosing corrosion problems through differentiation of metal fractions
This article hypothesizes how uniform and pitting corrosion are expressed in the dissolved and particulate metals concentrations of water samples. Three case studies highlight examples of how a metals differentiation technique was used in corrosion investigations. The technique offers insight into the nature and sometimes the cause of the corrosion, leading to selection of control strategies not necessarily suggested in standard corrosion reference books or the federal corrosion regulations. Additional research is needed to definitively show correlations between metal fractions and various corrosion and environmental mechanisms.
Effect of chlorine on corrosion in Drinking Water Systems
The federal Ground Water Rule may require some water utilities that do not use disinfection to begin doing so. A common method of disinfection is to add chlorine to the water. A study was performed to investigate the corrosive effects of chlorine in drinking water systems out of concern for staying in compliance with the corrosion control stipulations of the Lead and Copper Rule. Comparative corrosivity experiments using pipe loops were performed at two test sites. In this study, iron appears to be the most affected by free chlorine addition, followed by copper, followed by lead, which may or may not experience increased corrosion. Elevating the pH of the water at one site (originally at a pH of 7.8, 140 mg/L as calcium carbonate [CaCO3] total alkalinity, 6 mg/L dissolved oxygen) was beneficial in counteracting the corrosive effect of chlorinated water on iron. However, in this case, the elevation of pH was not beneficial in controlling corrosion of lead or copper. Adding orthophosphate decreased corrosion of lead and iron in contact with chlorinated water at the other site (original pH of 7.4, 290 mg/L as CaCO3 total alkalinity, 11 mg/L dissolved oxygen). However, copper corrosion appeared to reach an increased level in the long term.
Use of polyphosphate in corrosion control
When polyphosphate blends are added to water systems under certain conditions, leaching of pipe metal into the water may be significantly increased rather than decreased. Case studies of three Wisconsin water utilities uncovered possible negative consequences of using polyphosphate for corrosion control. These experiences suggest that water providers must exercise caution when adding polyphosphate to drinking water systems. Utilities should conduct off-line tests before using polyphosphate, and full-scale systems should be frequently monitored after polyphosphate addition. More research is needed to define the proper use of polyphosphates and to investigate alternatives to polyphosphates.
The Lead and Copper Rule: Proactive Detection and Response Are Key to Compliance
Industrywide misconceptions about the transfer of lead and copper from piping materials to water and the logistics of obtaining residential water samples have made it difficult for some utilities to comply with the Lead and Copper Rule. Standardized monitoring stations can help.
Copper Pipe Failure Microbiologically Influenced Corrosion
After a detailed investigation on the failure of copper water service pipes in a water distribution system, microbiologically influenced corrosion (MIC) was found to be the cause. Increased system disinfection appears to have remedied the problem. MIC is often overlooked in corrosion investigations of drinking water systems. This case history is a good example of telltale signs of MIC and the water environments in which this can occur.