Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
35
result(s) for
"Catargi, Bogdan"
Sort by:
Strategies of Radioiodine Ablation in Patients with Low-Risk Thyroid Cancer
by
Bridji, Boumédiène
,
Bastie, Delphine
,
Bournaud, Claire
in
Ablation
,
Ablation Techniques
,
Adenocarcinoma, Follicular - drug therapy
2012
This trial compared two thyrotropin-stimulation methods and two 131I doses for postoperative ablation in patients with low-risk thyroid cancer. Rates of ablation were similar in all treatment groups. Doses lower than those currently recommended may be adequate for this condition.
Radioiodine (
131
i) is administered to patients with thyroid cancer after total thyroidectomy for three reasons
1
–
3
: first, to eradicate normal-thyroid remnants (ablation) in order to achieve an undetectable serum thyroglobulin level; second, to irradiate any neoplastic focus in order to decrease the risk of recurrence; and third, to perform
131
I total-body scanning for persistent carcinoma.
Successful ablation is defined by the combination of undetectable serum thyroglobulin levels after thyrotropin stimulation and normal results on neck ultrasonography 6 to 12 months after
131
I administration.
2
,
3
When these criteria are met, approximately 1% of patients have a recurrence.
4
–
6
In . . .
Journal Article
Performance and patients’ satisfaction with the A7+TouchCare insulin patch pump system: A randomized controlled non-inferiority study
by
Melki, Vincent
,
Amadou, Coralie
,
Catargi, Bogdan
in
Biology and Life Sciences
,
Care and treatment
,
Catheters
2023
We assessed the performance and patient satisfaction of a new insulin patch pump, the A7+TouchCare (Medtrum), compared with the Omnipod system. This multicenter, randomized, open-label, controlled study enrolled 100 adult patients with type 1 or type 2 diabetes mellitus (A1C [greater than or equal to] 6.5% and [less than or equal to] 9.5%, i.e., 48 to 80 mmol/mol) who were assigned with the Omnipod or with the A7+TouchCare pump for 3 months. The primary study outcome was the glucose management indicator (GMI) calculated with continuous glucose monitoring (CGM). Premature withdrawals occurs respectively in 2 and 9 participants in the Omnipod and TouchCare groups. In the Per Protocol analysis, the difference in GMI between groups was 0.002% (95% confidence interval -0.251; 0.255). The non-inferiority was demonstrated since the difference between treatments did not overlap the pre-defined non-inferiority margin (0.4%). There was no significant difference in CGM parameters between groups. On average, patients in both groups were satisfied/very satisfied with the insulin pump system. Patients preferred Omnipod as an insulin management system and especially the patch delivery system but preferred the A7+TouchCare personal diabetes manager to control the system. This study showed that the A7+TouchCare insulin pump was as efficient as the Omnipod pump in terms of performance and satisfaction.
Journal Article
Performance and patients' satisfaction with the A7+TouchCare insulin patch pump system: A randomized controlled non-inferiority study
2023
We assessed the performance and patient satisfaction of a new insulin patch pump, the A7+TouchCare (Medtrum), compared with the Omnipod system. This multicenter, randomized, open-label, controlled study enrolled 100 adult patients with type 1 or type 2 diabetes mellitus (A1C [greater than or equal to] 6.5% and [less than or equal to] 9.5%, i.e., 48 to 80 mmol/mol) who were assigned with the Omnipod or with the A7+TouchCare pump for 3 months. The primary study outcome was the glucose management indicator (GMI) calculated with continuous glucose monitoring (CGM). Premature withdrawals occurs respectively in 2 and 9 participants in the Omnipod and TouchCare groups. In the Per Protocol analysis, the difference in GMI between groups was 0.002% (95% confidence interval -0.251; 0.255). The non-inferiority was demonstrated since the difference between treatments did not overlap the pre-defined non-inferiority margin (0.4%). There was no significant difference in CGM parameters between groups. On average, patients in both groups were satisfied/very satisfied with the insulin pump system. Patients preferred Omnipod as an insulin management system and especially the patch delivery system but preferred the A7+TouchCare personal diabetes manager to control the system. This study showed that the A7+TouchCare insulin pump was as efficient as the Omnipod pump in terms of performance and satisfaction.
Journal Article
Islets-on-Chip: A Tool for Real-Time Assessment of Islet Function Prior to Transplantation
2023
Islet transplantation improves metabolic control in patients with unstable type 1 diabetes. Clinical outcomes have been improving over the last decade, and the widely used beta-score allows the evaluation of transplantation results. However, predictive pre-transplantation criteria of islet quality for clinical outcomes are lacking. In this proof-of-concept study, we examined whether characterization of the electrical activity of donor islets could provide a criterion. Aliquots of 8 human donor islets from the STABILOT study, sampled from islet preparations before transplantation, were characterized for purity and split for glucose-induced insulin secretion and electrical activity using multi-electrode-arrays. The latter tests glucose concentration dependencies, biphasic activity, hormones, and drug effects (adrenalin, GLP-1, glibenclamide) and provides a ranking of CHIP-scores from 1 to 6 (best) based on electrical islet activity. The analysis was performed online in real time using a dedicated board or offline. Grouping of beta-scores and CHIP-scores with high, intermediate, and low values was observed. Further analysis indicated correlation between CHIP-score and beta-score, although significance was not attained (R = 0.51, p = 0.1). This novel approach is easily implantable in islet isolation units and might provide means for the prediction of clinical outcomes. We acknowledge the small cohort size as the limitation of this pilot study.
Journal Article
DIABEO App Software and Telemedicine Versus Usual Follow-Up in the Treatment of Diabetic Patients: Protocol for the TELESAGE Randomized Controlled Trial
by
Anne Farret
,
Bogdan Catargi
,
Sylvia Franc
in
[SDV.MHEP]Life Sciences [q-bio]/Human health and pathology
,
[SDV]Life Sciences [q-bio]
,
Algorithms
2018
Self-management of diabetes minimizes the risk of macrovascular and microvascular complications, but understanding and/or adherence to self-management recommendations is often suboptimal. DIABEO is a smartphone app (downloaded via the internet) used to calculate bolus insulin doses. A previous study (TELEDIAB 1) showed that the use of DIABEO was associated with a significant improvement in glycemic control in patients with poorly controlled type 1 diabetes mellitus, particularly when combined with teleconsultations with physicians.
Here, we present the protocol for a new study (Suivi A Grande Echelle d'une cohorte de diabétiques de type 1 et de type 2 sous schéma insulinique basal bolus par la TELEmédecine; abbreviated TELESAGE), conducted in a larger population of diabetic patients with poorly controlled basal-bolus insulin levels.
TELESAGE is a multicenter, double-randomized, open-label, three parallel-arms study, conducted in approximately 100 centers in France. The study will compare a control group (arm 1: usual follow-up) with two DIABEO telemedicine systems: (1) physician-assisted telemedicine (arm 2), and (2) nurse-assisted telemonitoring and teleconsultations by a diabetologist's task delegation (arm 3). Initial randomization will allocate the study arms in 12 French regions. A second randomization will assign patients in the groups allocated to each studied region. The primary objective of TELESAGE will be to investigate the effect of the DIABEO telemedicine system versus usual follow-up, with respect to improvements in the glycated hemoglobin levels of approximately 696 diabetic patients with poorly controlled basal-bolus insulin levels.
The TELESAGE study is sponsored by Sanofi (Gentilly, France). A primary completion date is expected in June 2018, and publication of results is expected within 6 months of work completion.
The TELESAGE study is expected to confirm the previous results of the TELEDIAB 1 study using a larger sample of diabetic patients. It is also expected to evaluate a nurse-assisted telemonitoring system. We will assess the potential of the DIABEO telemedicine service in terms of its utility and explore whether it can become an integral part of diabetes care for patients.
ClinicalTrials.gov NCT02287532; https://clinicaltrials.gov/ct2/show/NCT02287532 (Archived by WebCite at http://www.webcitation.org/6ykajhJKd).
Journal Article
Thyroidectomy without Radioiodine in Patients with Low-Risk Thyroid Cancer
2022
In this randomized phase 3 trial involving patients with low-risk differentiated thyroid cancer undergoing thyroidectomy, a follow-up strategy that did not involve the use of radioiodine was noninferior to the use of radioiodine in the response to treatment at 3 years.
Journal Article
Diabeo Software Enabling Individualized Insulin Dose Adjustments Combined With Telemedicine Support Improves HbA₁c in Poorly Controlled Type 1 Diabetic Patients: A 6-month, randomized, open-label, parallel-group, multicenter trial (TeleDiab 1 Study)
by
Franc, Sylvia
,
Clergeot, Annie
,
Melki, Vincent
in
Adult
,
adults
,
Biochemistry, Molecular Biology
2011
OBJECTIVE: To demonstrate that Diabeo software enabling individualized insulin dose adjustments combined with telemedicine support significantly improves HbA₁c in poorly controlled type 1 diabetic patients. RESEARCH DESIGN AND METHODS: In a six-month open-label parallel-group, multicenter study, adult patients (n = 180) with type 1 diabetes (>1 year), on a basal-bolus insulin regimen (>6 months), with HbA₁c ≥8%, were randomized to usual quarterly follow-up (G1), home use of a smartphone recommending insulin doses with quarterly visits (G2), or use of the smartphone with short teleconsultations every 2 weeks but no visit until point end (G3). RESULTS: Six-month mean HbA₁c in G3 (8.41 ± 1.04%) was lower than in G1 (9.10 ± 1.16%; P = 0.0019). G2 displayed intermediate results (8.63 ± 1.07%). The Diabeo system gave a 0.91% (0.60; 1.21) improvement in HbA₁c over controls and a 0.67% (0.35; 0.99) reduction when used without teleconsultation. There was no difference in the frequency of hypoglycemic episodes or in medical time spent for hospital or telephone consultations. However, patients in G1 and G2 spent nearly 5 h more than G3 patients attending hospital visits. CONCLUSIONS: The Diabeo system gives a substantial improvement to metabolic control in chronic, poorly controlled type 1 diabetic patients without requiring more medical time and at a lower overall cost for the patient than usual care.
Journal Article
Performance and patients' satisfaction with the A7+TouchCare insulin patch pump system: A randomized controlled non-inferiority study
2023
We assessed the performance and patient satisfaction of a new insulin patch pump, the A7+TouchCare (Medtrum), compared with the Omnipod system. This multicenter, randomized, open-label, controlled study enrolled 100 adult patients with type 1 or type 2 diabetes mellitus (A1C [greater than or equal to] 6.5% and [less than or equal to] 9.5%, i.e., 48 to 80 mmol/mol) who were assigned with the Omnipod or with the A7+TouchCare pump for 3 months. The primary study outcome was the glucose management indicator (GMI) calculated with continuous glucose monitoring (CGM). Premature withdrawals occurs respectively in 2 and 9 participants in the Omnipod and TouchCare groups. In the Per Protocol analysis, the difference in GMI between groups was 0.002% (95% confidence interval -0.251; 0.255). The non-inferiority was demonstrated since the difference between treatments did not overlap the pre-defined non-inferiority margin (0.4%). There was no significant difference in CGM parameters between groups. On average, patients in both groups were satisfied/very satisfied with the insulin pump system. Patients preferred Omnipod as an insulin management system and especially the patch delivery system but preferred the A7+TouchCare personal diabetes manager to control the system. This study showed that the A7+TouchCare insulin pump was as efficient as the Omnipod pump in terms of performance and satisfaction.
Journal Article
Slow potentials encode intercellular coupling and insulin demand in pancreatic beta cells
2015
Aims/hypothesis
Ion fluxes constitute a major integrative signal in beta cells that leads to insulin secretion and regulation of gene expression. Understanding these electrical signals is important for deciphering the endogenous algorithms used by islets to attain homeostasis and for the design of new sensors for monitoring beta cell function.
Methods
Mouse and human islets were cultured on multielectrode arrays (MEAs) for 3–13 days. Extracellular electrical activities received on each electrode were continuously amplified and recorded for offline characterisation.
Results
Differential band-pass filtering of MEA recordings of mouse islets showed two extracellular voltage waveforms: action potentials (lasting 40–60 ms) and very robust slow potentials (SPs, lasting 800–1,500 ms), the latter of which have not been described previously. The frequency of SPs directly correlated with glucose concentration, peaked at 10 mmol/l glucose and was further augmented by picomolar concentrations of glucagon-like peptide-1. SPs required the closure of ATP-dependent potassium channels as they were induced by glucose or glibenclamide but were not elicited by KCl-induced depolarisation. Pharmacological tools and the use of beta cell specific knockout mice showed that SPs reflected cell coupling via connexin 36. Moreover, increasing and decreasing glucose ramps showed hysteresis with reduced glucose sensitivity during the decreasing phase. SPs were also observed in human islets and could be continuously recorded over 24 h.
Conclusions/interpretation
This novel electrical signature reflects the syncytial function of the islets and is specific to beta cells. Moreover, the observed hysteresis provides evidence for an endogenous algorithm naturally present in islets to protect against hypoglycaemia.
Journal Article
Five-Year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome: A Meta-Analysis
by
Daoud, Frederic C.
,
Karjalainen, Pasi P.
,
Catargi, Bogdan
in
Acute coronary syndrome
,
Acute coronary syndromes
,
Analysis
2023
(1) Background: Percutaneous coronary interventions (PCI) in patients with acute coronary syndrome (ACS) are performed with titanium-nitride-oxide-coated stents (TiNOSs) or drug-eluting stents (DESs). The initial completion of this prospective systematic literature review (SLR) of prospective randomized controlled trials (RCTs) showed that TiNOSs are non-inferior to DESs in major adverse cardiac event (MACE) rates and present a lower risk of recurrent myocardial infarction (MI) at 1-year follow-up. This iteration of the SLR protocol performs the critical assessment of 5-year follow-up outcomes with clinical validity and generalizability assessments. (2) Methods: The previously described SLR and meta-analysis protocol, per PRISMA, Cochrane methods, and GRADE, was applied to 5-year follow-up outcomes. (3) Results: Three RCTs were eligible, comprising 1620 patients with TiNOS vs. 1123 with DES. The pooled risk ratios (RRs) and 95% confidence intervals were MACE 0.82 [0.68, 0.99], MI 0.58 [0.44, 0.78], cardiac death (CD) 0.46 [0.28, 0.76], ischemia-driven target lesion revascularization (TLR) 1.03 [0.79, 1.33], probable or definite stent thrombosis (ST) 0.32 [0.21, 0.59], and all-cause mortality (TD) 0.84 [0.63, 1.12]. The evidence certainty was high in MACE, CD, MI, and ST, and moderate in TLR and TD. (4) Conclusions: TiNOSs in ACS at 5-year follow-up appear safer than DESs and equally efficacious. The pooled RRs stratified by clinical presentation and stent type will be required to test this meta-analysis’s clinical validity and generalize its results to patient populations with varying proportions of clinical presentations and DES options.
Journal Article