Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
49 result(s) for "Choi, Hongsoo"
Sort by:
Magnetic Actuation Based Motion Control for Microrobots: An Overview
Untethered, controllable, mobile microrobots have been proposed for numerous applications, ranging from micro-manipulation, in vitro tasks (e.g., operation of microscale biological substances) to in vivo applications (e.g., targeted drug delivery; brachytherapy; hyperthermia, etc.), due to their small-scale dimensions and accessibility to tiny and complex environments. Researchers have used different magnetic actuation systems allowing custom-designed workspace and multiple degrees of freedom (DoF) to actuate microrobots with various motion control methods from open-loop pre-programmed control to closed-loop path-following control. This article provides an overview of the magnetic actuation systems and the magnetic actuation-based control methods for microrobots. An overall benchmark on the magnetic actuation system and control method is also discussed according to the applications of microrobots.
Recent Developments in Metallic Degradable Micromotors for Biomedical and Environmental Remediation Applications
HighlightsThis review discusses the potential of degradable metallic micromotors for a variety of biomedical and environmental applications.The design principles, fabrication techniques and degradation mechanisms of degradable metallic micromotors are reviewed in detail.Challenges and future directions for the development of degradable metallic micromotors for real-life applications are presented.Synthetic micromotor has gained substantial attention in biomedicine and environmental remediation. Metal-based degradable micromotor composed of magnesium (Mg), zinc (Zn), and iron (Fe) have promise due to their nontoxic fuel-free propulsion, favorable biocompatibility, and safe excretion of degradation products Recent advances in degradable metallic micromotor have shown their fast movement in complex biological media, efficient cargo delivery and favorable biocompatibility. A noteworthy number of degradable metal-based micromotors employ bubble propulsion, utilizing water as fuel to generate hydrogen bubbles. This novel feature has projected degradable metallic micromotors for active in vivo drug delivery applications. In addition, understanding the degradation mechanism of these micromotors is also a key parameter for their design and performance. Its propulsion efficiency and life span govern the overall performance of a degradable metallic micromotor. Here we review the design and recent advancements of metallic degradable micromotors. Furthermore, we describe the controlled degradation, efficient in vivo drug delivery, and built-in acid neutralization capabilities of degradable micromotors with versatile biomedical applications. Moreover, we discuss micromotors’ efficacy in detecting and destroying environmental pollutants. Finally, we address the limitations and future research directions of degradable metallic micromotors.
Shape-memory effect in twisted ferroic nanocomposites
The shape recovery ability of shape-memory alloys vanishes below a critical size (~50 nm), which prevents their practical applications at the nanoscale. In contrast, ferroic materials, even when scaled down to dimensions of a few nanometers, exhibit actuation strain through domain switching, though the generated strain is modest (~1%). Here, we develop freestanding twisted architectures of nanoscale ferroic oxides showing shape-memory effect with a giant recoverable strain (>8%). The twisted geometrical design amplifies the strain generated during ferroelectric domain switching, which cannot be achieved in bulk ceramics or substrate-bonded thin films. The twisted ferroic nanocomposites allow us to overcome the size limitations in traditional shape-memory alloys and open new avenues in engineering large-stroke shape-memory materials for small-scale actuating devices such as nanorobots and artificial muscle fibrils. Shape-memory materials are promising actuation sources for small-scale machines. The authors demonstrate that domain switching in twisted ferroic nanocomposites enables a giant shape-memory effect and superelasticity in the nanoscale structure.
Fabrication and Underwater Testing of a Vector Hydrophone Comprising a Triaxial Piezoelectric Accelerometer and Spherical Hydrophone
A vector hydrophone is an underwater acoustic sensor that can detect the direction of a sound source. Wide-band characteristics and high sensitivity enhance the performance of underwater surveillance systems in complex environments. A vector hydrophone comprising a triaxial piezoelectric accelerometer and spherical hydrophone was fabricated and tested in the air and underwater. The vector hydrophone was designed to exceed the quantitative figures of merit (i.e., receiving voltage sensitivity and bandwidth) of commercially available hydrophones. Accelerometer performance was enhanced by placing a pair of piezoelectric single crystals on each axis and modifying the seismic mass material. The receiving voltage sensitivity of the omnidirectional hydrophone was approximately −160 dB relative to 1 V/μPa with the amplifier in water; the sensitivity of the accelerometer exceeded 300 mV/g in air and −215 dB relative to 1 V/μPa underwater over the frequency range of interest. The receiving directivity of the vector hydrophone was validated underwater, which confirmed that it could detect the direction of a sound source.
Integrated Piezoelectric AlN Thin Film with SU-8/PDMS Supporting Layer for Flexible Sensor Array
This research focuses on the development of a flexible tactile sensor array consisting of aluminum nitride (AlN) based on micro-electro-mechanical system (MEMS) technology. A total of 2304 tactile sensors were integrated into a small area of 2.5 × 2.5 cm2. Five hundred nm thick AlN film with strong c-axis texture was sputtered on Cr/Au/Cr (50/50/5 nm) layers as the sacrificial layer coated on a Si wafer. To achieve device flexibility, polydimethylsiloxane (PDMS) polymer and SU-8 photoresist layer were used as the supporting layers after etching away a release layer. Twenty-five mM (3-mercaptopropyl) trimethoxysilane (MPTMS) improves the adhesion between metal and polymers due to formation of a self-assembled monolayer (SAM) on the surface of the top electrode. The flexible tactile sensor has 8 × 8 channels and each channel has 36 sensor elements with nine SU-8 bump blocks. The tactile sensor array was demonstrated to be flexible by bending 90 degrees. The tactile sensor array was demonstrated to show clear spatial resolution through detecting the distinct electrical response of each channel under local mechanical stimulus.
Fabrication and Characterization of a Magnetic Drilling Actuator for Navigation in a Three-dimensional Phantom Vascular Network
Intravascular microrobots have emerged as a promising tool for vascular diseases. They can be wirelessly and precisely manipulated with a high degree of freedom. Previous studies have evaluated their drilling performance and locomotion, and showed the feasibility of using microrobots for biomedical applications in two-dimensional space. However, it is critical to validate micro-drillers in a three-dimensional (3D) environment because gravity plays an important role in a 3D environment and significantly affects the performance of the micro-drillers in vascular networks. In this work, we fabricated magnetic drilling actuators (MDAs) and characterized their locomotion and drilling performance in vascular network-mimicking fluidic channels. The MDAs were precisely manipulated in the fluidic channel network in both horizontal and vertical planes, selecting and moving through the desired path via the junctions of multiple channels. The MDAs also accurately navigated an artificial thrombosis in an artificial 3D vascular network and successfully drilled through it. The results obtained here confirmed the precise manipulation and drilling performance of the developed MDAs in 3D. We think that the MDAs presented in this paper have great potential as intravascular drillers for precise thrombus treatment.
Sialyllactose preserves residual hearing after cochlear implantation
In individuals with hearing loss, protection of residual hearing is essential following cochlear implantation to facilitate acoustic and electric hearing. Hearing preservation requires slow insertion, atraumatic electrode and delivery of the optimal quantity of a pharmacological agent. Several studies have reported variable hearing outcomes with osmotic pump-mediated steroid delivery. New drugs, such as sialyllactose (SL) which have anti-inflammatory effect in many body parts, can prevent tissue overgrowth. In the present study, the positive effects of the pharmacological agent SL against insults were evaluated in vitro using HEI-OC1 cells. An animal model to simulate the damage due to electrode insertion during cochlear implantation was used. SL was delivered using osmotic pumps to prevent loss of the residual hearing in this animal model. Hearing deterioration, tissue fibrosis and ossification were confirmed in this animal model. Increased gene expressions of inflammatory cytokines were identified in the cochleae following dummy electrode insertion. Following the administration of SL, insertion led to a decrease in hearing threshold shifts, tissue reactions, and inflammatory markers. These results emphasize the possible role of SL in hearing preservation and improve our understanding of the mechanism underlying hearing loss after cochlear implantation.
A microelectromechanical system artificial basilar membrane based on a piezoelectric cantilever array and its characterization using an animal model
We proposed a piezoelectric artificial basilar membrane (ABM) composed of a microelectromechanical system cantilever array. The ABM mimics the tonotopy of the cochlea: frequency selectivity and mechanoelectric transduction. The fabricated ABM exhibits a clear tonotopy in an audible frequency range (2.92–12.6 kHz). Also, an animal model was used to verify the characteristics of the ABM as a front end for potential cochlear implant applications. For this, a signal processor was used to convert the piezoelectric output from the ABM to an electrical stimulus for auditory neurons. The electrical stimulus for auditory neurons was delivered through an implanted intra-cochlear electrode array. The amplitude of the electrical stimulus was modulated in the range of 0.15 to 3.5 V with incoming sound pressure levels (SPL) of 70.1 to 94.8 dB SPL. The electrical stimulus was used to elicit an electrically evoked auditory brainstem response (EABR) from deafened guinea pigs. EABRs were successfully measured and their magnitude increased upon application of acoustic stimuli from 75 to 95 dB SPL. The frequency selectivity of the ABM was estimated by measuring the magnitude of EABRs while applying sound pressure at the resonance and off-resonance frequencies of the corresponding cantilever of the selected channel. In this study, we demonstrated a novel piezoelectric ABM and verified its characteristics by measuring EABRs.
Frequency‐Selective, Multi‐Channel, Self‐Powered Artificial Basilar Membrane Sensor with a Spiral Shape and 24 Critical Bands Inspired by the Human Cochlea
A spiral‐artificial basilar membrane (S‐ABM) sensor is reported that mimics the basilar membrane (BM) of the human cochlea and can detect sound by separating it into 24 sensing channels based on the frequency band. For this, an analytical function is proposed to design the width of the BM so that the frequency bands are linearly located along the length of the BM. To fabricate the S‐ABM sensor, a spiral‐shaped polyimide film is used as a vibrating membrane, with maximum displacement at locations corresponding to specific frequency bands of sound, and attach piezoelectric sensor modules made of poly(vinylidene fluoride‐trifluoroethylene) film on top of the polyimide film to measure the vibration amplitude at each channel location. As the result, the S‐ABM sensor implements a characteristic frequency band of 96‐12,821 Hz and 24‐independent critical bands. Using real‐time signals from discriminate channels, it is demonstrated that the sensor can rapidly identify the operational noises from equipment processes as well as vehicle sounds from environmental noises on the road. The sensor can be used in a variety of applications, including speech recognition, dangerous situation recognition, hearing aids, and cochlear implants, and more. The spiral‐artificial basilar membrane (S‐ABM) sensor is a biomimetic acoustic sensor consisting of an artificial basilar membrane (ABM) that discriminates sound into frequency bands, 24 independent critical bands, and piezoelectric sensor modules that generates an electrical signal by the vibration of the S‐ABM. An early detection system is developed that can detect and distinguish potential hazards that may occur in industrial processes and driving situations through the sensor.
Development of a High-Density Piezoelectric Micromachined Ultrasonic Transducer Array Based on Patterned Aluminum Nitride Thin Film
This study presents the fabrication and characterization of a piezoelectric micromachined ultrasonic transducer (pMUT; radius: 40 µm) using a patterned aluminum nitride (AlN) thin film as the active piezoelectric material. A 20 × 20 array of pMUTs using a 1 µm thick AlN thin film was designed and fabricated on a 2 × 2 mm2 footprint for a high fill factor. Based on the electrical impedance and phase of the pMUT array, the electromechanical coefficient was ~1.7% at the average resonant frequency of 2.82 MHz in air. Dynamic displacement of the pMUT surface was characterized by scanning laser Doppler vibrometry. The pressure output while immersed in water was 19.79 kPa when calculated based on the peak displacement at the resonant frequency. The proposed AlN pMUT array has potential applications in biomedical sensing for healthcare, medical imaging, and biometrics.