Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
189
result(s) for
"Cook, Gary J. R."
Sort by:
Imaging body composition in cancer patients: visceral obesity, sarcopenia and sarcopenic obesity may impact on clinical outcome
by
Cook, Gary J. R.
,
Dinkel, Charlotte
,
Mahajan, Abhishek
in
Clinical outcomes
,
Diagnostic Radiology
,
Imaging
2015
In recent years, there has been increasing interest in the influence of body composition on oncological patient outcomes. Visceral obesity, sarcopenia and sarcopenic obesity have been identified as adverse factors in cancer patients. Imaging quantification of body composition such as lean muscle mass and fat distribution is a potentially valuable tool. This review describes the following imaging techniques that may be used to assess body composition: dual-energy X-ray absorptiometry (DXA), computed tomography (CT) and magnetic resonance imaging (MRI). CT and MRI are acquired as part of oncological patient care, thus providing an opportunity to integrate body composition assessment into the standard clinical pathway and allowing supportive care to be commenced as appropriate to improve outcome.
Main Messages
•
Sarcopenia, sarcopenic obesity and visceral obesity are adverse prognostic factors in cancer patients.
•
CT and MRI are the current gold standard in body composition evaluation.
•
Body composition may affect chemotherapy tolerance and toxicities.
Journal Article
Molecular imaging of hypoxia in non-small-cell lung cancer
by
Cook, Gary J. R.
,
Blower, Philip J.
,
Goh, Vicky
in
Animals
,
Carcinoma, Non-Small-Cell Lung - diagnostic imaging
,
Carcinoma, Non-Small-Cell Lung - metabolism
2015
Non-small-cell lung cancer (NSCLC) is the commonest cancer worldwide but survival remains poor with a high risk of relapse, particularly after nonsurgical treatment. Hypoxia is present in a variety of solid tumours, including NSCLC. It is associated with treatment resistance and a poor prognosis, although when recognised may be amenable to different treatment strategies. Thus, noninvasive assessment of intratumoral hypoxia could be used to stratify patients for modification of subsequent treatment to improve tumour control. Molecular imaging approaches targeting hypoxic cells have shown some early success in the clinical setting. This review evaluates the evidence for hypoxia imaging using PET in NSCLC and explores its potential clinical utility.
Journal Article
Joint EANM-SNMMI guideline on the role of 2- 18 FFDG PET/CT in no special type breast cancer : (endorsed by the ACR, ESSO, ESTRO, EUSOBI/ESR, and EUSOMA)
by
Schoones, Jan W
,
Rubio, Isabel T
,
Peeters, Marie-Jeanne Vrancken
in
Breast cancer
,
Breast Neoplasms - diagnostic imaging
,
Computed tomography
2024
There is much literature about the role of 2-[
F]FDG PET/CT in patients with breast cancer (BC). However, there exists no international guideline with involvement of the nuclear medicine societies about this subject.
To provide an organized, international, state-of-the-art, and multidisciplinary guideline, led by experts of two nuclear medicine societies (EANM and SNMMI) and representation of important societies in the field of BC (ACR, ESSO, ESTRO, EUSOBI/ESR, and EUSOMA).
Literature review and expert discussion were performed with the aim of collecting updated information regarding the role of 2-[
F]FDG PET/CT in patients with no special type (NST) BC and summarizing its indications according to scientific evidence. Recommendations were scored according to the National Institute for Health and Care Excellence (NICE) criteria.
Quantitative PET features (SUV, MTV, TLG) are valuable prognostic parameters. In baseline staging, 2-[
F]FDG PET/CT plays a role from stage IIB through stage IV. When assessing response to therapy, 2-[
F]FDG PET/CT should be performed on certified scanners, and reported either according to PERCIST, EORTC PET, or EANM immunotherapy response criteria, as appropriate. 2-[
F]FDG PET/CT may be useful to assess early metabolic response, particularly in non-metastatic triple-negative and HER2+ tumours. 2-[
F]FDG PET/CT is useful to detect the site and extent of recurrence when conventional imaging methods are equivocal and when there is clinical and/or laboratorial suspicion of relapse. Recent developments are promising.
2-[
F]FDG PET/CT is extremely useful in BC management, as supported by extensive evidence of its utility compared to other imaging modalities in several clinical scenarios.
Journal Article
68GaGa‐PSMA‐11 PET/CT for baseline staging of high‐risk prostate cancer: A real‐world study
2026
Objective To use real‐world data to determine the clinical risk factors that are predictive of metastatic disease in high‐risk prostate cancer (PCa) patients undergoing staging [68Ga]Ga‐Prostate‐Specific Membrane Antigen (PSMA)‐11 positron emission tomography combined with computed tomography (PET/CT). Methods Subjects with newly diagnosed PCa who underwent [68Ga]Ga‐PSMA‐11 PET/CT between 1/2/20 and 1/4/23, with one or more of three major risk factors (prostate‐specific antigen (PSA) ≥ 20, MRI T‐stage ≥ 3 or International Society of Urological Pathology (ISUP) grade ≥ 3) were included. Metrics collected included [68Ga]Ga‐PSMA‐11 PET/CT primary index tumour maximum standardized uptake value (SUVmax), TNM stage, tumour histology, patient age, body mass index and treatment type. Results A total of 525 subjects were eligible for inclusion. A total of 22.1% had nodal or distant metastases on the baseline [68Ga]Ga‐PSMA‐11 PET/CT (11.8% with one major risk factor, 25.6% with two and 43.5% with three). All three major risk factors (PSA ≥ 20, MRI T‐stage ≥ 3, ISUP grade ≥ 3) and the presence of a higher percentage of positive biopsy cores were significant independent risk factors for the presence of metastatic disease on multivariable analysis. Primary index tumour SUVmax was associated with clinical risk factors, including ISUP grade in the surgical cohort. A total of 146 (27.8%) subjects underwent a radical prostatectomy, and 379 (72.2%) received non‐surgical management (including 242 (46.1%) who received curative intent radiotherapy (RT)). Conclusion This study provides real‐world validation of the clinical risk factors used for the ProPSMA study for [68Ga]Ga‐PSMA‐11 PET/CT scan eligibility, which represent significant independent risk factors for the presence of nodal or distant metastases on baseline [68Ga]Ga‐PSMA‐11 PET/CT.
Journal Article
Inter-rater and intra-rater agreement of 99mTc-labelled NM-01, a single-domain programmed death-ligand 1 (PD-L1) antibody, using quantitative SPECT/CT in non-small cell lung cancer
2023
BackgroundImmune checkpoint inhibitors, including those against programmed cell death protein-1 (PD-1) or its ligand (PD-L1), are routinely used to treat non-small cell lung cancer (NSCLC). PD-L1 is a validated prognostic and predictive immunohistochemical biomarker of anti-PD-1/PD-L1 therapy but displays temporospatial heterogeneity of expression. Non-invasive radiopharmaceutical techniques, including technetium-99m [99mTc]-labelled anti-PD-L1 single-domain antibody (NM-01) SPECT/CT, have the potential to improve the predictive value of PD-L1 assessment. This study aims to determine the inter- and intra-rater agreement of the quantitative measurement of [99mTc]NM-01 SPECT/CT in NSCLC.MethodsParticipants (n = 14) with untreated advanced NSCLC underwent [99mTc]NM-01 SPECT/CT at baseline (n = 3) or at baseline plus 9-week follow-up (n = 11). [99mTc]NM-01 uptake (of primary lung, lymph node, thoracic and distant metastases, and healthy reference tissues) was measured using SUVmax and malignant lesion-to-blood pool ratios with Siemens xSPECT Broad Quantification software by three independent raters. Intraclass correlation coefficients (ICC) were calculated and Bland–Altman plot analysis performed to determine inter- and intra-rater agreement.ResultsThere was excellent inter-rater agreement of manual freehand SUVmax scores of primary lung tumour (T; n = 25; ICC 1.00; 95% CI 0.99–1.00), individual lymph node metastases (LN; n = 56; ICC 0.97; 95% CI 0.95–0.98), thoracic metastases (ThMet; n = 9; ICC 0.94; 95% CI 0.83–0.99) and distant metastases (DisMet; n = 21; ICC 0.91; 95% CI 0.83–0.96). The inter-rater ICCs of tumour-to-blood pool (T:BP), LN:BP, ThMet:BP and DisMet:BP measures of [99mTc]NM-01 uptake also demonstrated good or excellent agreement. Manual freehand scoring of T, LN, ThMet, DisMet and their ratios using [99mTc]NM-01 SPECT/CT following a 28-day interval was consistent for all raters with good or excellent intra-rater agreement demonstrated (ICCs range 0.86–1.00).ConclusionQuantitative assessment of [99mTc]NM-01 SPECT/CT in NSCLC, using SUVmax of malignant primary or metastatic lesions and their ratios with healthy reference tissues, demonstrated good or excellent inter- and intra-rater agreement in this study. Further validation with ongoing and future larger cohort studies is now warranted.Clinical trial registrationClinicalTrials.gov identifier no. NCT04436406 (registered 18th June 2020; available at https://clinicaltrials.gov/ct2/show/NCT04436406) and NCT04992715 (registered 5th August 2021; available at https://clinicaltrials.gov/ct2/show/NCT04992715).
Journal Article
Radiomic assessment of oesophageal adenocarcinoma: a critical review of 18F-FDG PET/CT, PET/MRI and CT
by
O’Shea, Robert J
,
Withey, Sam
,
Rookyard, Chris
in
Cancer
,
Esophageal cancer
,
Fluorine isotopes
2022
ObjectivesRadiomic models present an avenue to improve oesophageal adenocarcinoma assessment through quantitative medical image analysis. However, model selection is complicated by the abundance of available predictors and the uncertainty of their relevance and reproducibility. This analysis reviews recent research to facilitate precedent-based model selection for prospective validation studies. MethodsThis analysis reviews research on 18F-FDG PET/CT, PET/MRI and CT radiomics in oesophageal adenocarcinoma between 2016 and 2021. Model design, testing and reporting are evaluated according to the Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis or Diagnosis (TRIPOD) score and Radiomics Quality Score (RQS). Key results and limitations are analysed to identify opportunities for future research in the area.ResultsRadiomic models of stage and therapeutic response demonstrated discriminative capacity, though clinical applications require greater sensitivity. Although radiomic models predict survival within institutions, generalisability is limited. Few radiomic features have been recommended independently by multiple studies.ConclusionsFuture research must prioritise prospective validation of previously proposed models to further clinical translation.
Journal Article
99mTc-labelled anti-Programmed Death-Ligand 1 single-domain antibody SPECT/CT: a novel imaging biomarker for myocardial PD-L1 expression
by
Johnson, Jessica
,
Hughes, Daniel Johnathan
,
Ting, Hong Hoi
in
Antibodies
,
Biomarkers
,
Cell death
2023
BackgroundMyocardial programmed death-ligand 1 (PD-L1) expression is implicated in immune checkpoint inhibitor (ICI)-associated myocarditis. Measurement of myocardial PD-L1 expression may have potential use as a mechanistic and predictive biomarker. The aim of this study was to determine non-invasive assessment of myocardial PD-L1 expression using [99mTc]-labelled anti-PD-L1 single-domain antibody (NM-01) SPECT/CT.MethodsThoracic [99mTc]NM-01 SPECT/CT was performed in lung cancer patients (n = 10) at baseline and 9-weeks following anti-programmed cell death protein 1 (PD-1) therapy. Baseline and 9-week left ventricular and right ventricular to blood pool ratios (LVmax:BP) and (RVmax:BP) were measured. LVmax was compared to background skeletal muscle (musclemax). Intra-rater reliability was determined by intraclass correlation coefficient (ICC) and Bland–Altman analysis.ResultsMean LVmax:BP values were 2.76 ± 0.67 at baseline vs 2.55 ± 0.77 at 9 weeks (p = 0.42). Mean RVmax:BP was 1.82 ± 0.32 at baseline vs 1.76 ± 0.45 at 9 weeks (p = 0.67). Myocardial PD-L1 expression was at least threefold greater than skeletal muscle at baseline for the LV (LVmax to musclemax 3.71 ± 0.77 vs 0.98 ± 0.20 (p < 0.001)) and at least twofold for the RV (LVmax to musclemax 2.49 ± 0.63 vs 0.98 ± 0.20 (p < 0.001)). There was excellent intra-rater reliability for LVmax:BP with ICC 0.99 (95% confidence interval 0.94–0.99, p < 0.001), mean bias -0.05 ± 0.14 (95% limits of agreement -0.32 to 0.21). There were no major adverse cardiovascular events or myocarditis during follow-up.ConclusionThis study is the first to report PD-L1 expression of the heart that can be quantified non-invasively without invasive myocardial biopsy, with high reliability and specificity. This technique can be applied to investigate myocardial PD-L1 expression in ICI-associated myocarditis and cardiomyopathies.Clinical trial registration PD-L1 Expression in Cancer (PECan) study (NCT04436406). https://clinicaltrials.gov/ct2/show/NCT04436406 June 18th, 2020.
Journal Article
Standardisation of conventional and advanced iterative reconstruction methods for Gallium-68 multi-centre PET-CT trials
by
Krokos Georgios
,
Marsden, Paul K
,
Cook, Gary J
in
Algorithms
,
Background noise
,
Computed tomography
2021
PurposeTo assess the applicability of the Fluorine-18 performance specifications defined by EANM Research Ltd (EARL), in Gallium-68 multi-centre PET-CT trials using conventional (ordered subset expectation maximisation, OSEM) and advanced iterative reconstructions which include the systems’ point spread function (PSF) and a Bayesian penalised likelihood algorithm (BPL) commercially known as Q.CLEAR. The possibility of standardising the two advanced reconstruction methods was examined.MethodsThe NEMA image quality phantom was filled with Gallium-68 and scanned on a GE PET-CT system. PSF and BPL with varying post-reconstruction Gaussian filter width (2–6.4 mm) and penalisation factor (200–1200), respectively, were applied. The average peak-to-valley ratio from six profiles across each sphere was estimated to inspect any edge artefacts. Image noise was assessed using background variability and image roughness. Six GE and Siemens PET-CT scanners provided Gallium-68 images of the NEMA phantom using both conventional and advanced reconstructions from which the maximum, mean and peak recoveries were drawn. Fourteen patients underwent 68Ga-PSMA PET-CT imaging. BPL (200-1200) reconstructions of the data were compared against PSF smoothed with a 6.4-mm Gaussian filter.ResultsA Gaussian filter width of approximately 6 mm for PSF and a penalisation factor of 800 for BPL were needed to suppress the edge artefacts. In addition, those reconstructions provided the closest agreement between the two advanced iterative reconstructions and low noise levels with the background variability and the image roughness being lower than 7.5% and 11.5%, respectively. The recoveries for all methods generally performed at the lower limits of the EARL specifications, especially for the 13- and 10-mm spheres for which up to 27% (conventional) and 41% (advanced reconstructions) lower limits are suggested. The lesion standardised uptake values from the clinical data were significantly different between BPL and PSF smoothed with a Gaussian filter of 6.4 mm wide for all penalisation factors except for 800 and 1000.ConclusionIt is possible to standardise the advanced reconstruction methods with the reconstruction parameters being also sufficient for minimising the edge artefacts and noise in the images. For both conventional and advanced reconstructions, Gallium-68 specific recovery coefficient limits were required, especially for the smallest phantom spheres.
Journal Article
Optimisation of CT protocols in PET-CT across different scanner models using different automatic exposure control methods and iterative reconstruction algorithms
by
Mackewn, Jane
,
Sugama, Chicklore
,
Pike, Lucy
in
Algorithms
,
Automatic control
,
Computed tomography
2021
BackgroundA significant proportion of the radiation dose from a PET-CT examination is dependent on the CT protocol, which should be optimised for clinical purposes. Matching protocols on different scanners within an imaging centre is important for the consistency of image quality and dose. This paper describes our experience translating low-dose CT protocols between scanner models utilising different automatic exposure control (AEC) methods and reconstruction algorithms.MethodsThe scanners investigated were a newly installed Siemens Biograph mCT PET with 64-slice SOMATOM Definition AS CT using sinogram affirmed iterative reconstruction (SAFIRE) and two GE Discovery 710 PET scanners with 128-slice Optima 660 CT using adaptive statistical reconstruction (ASiR). Following exploratory phantom work, 33 adult patients of various sizes were scanned using the Siemens scanner and matched to patients scanned using our established GE protocol to give 33 patient pairs. A comparison of volumetric CT dose index (CTDIvol) and image noise within these patient pairs informed optimisation, specifically for obese patients. Another matched patient study containing 27 patient pairs was used to confirm protocol matching. Size-specific dose estimates (SSDEs) were calculated for patients in the second cohort. With the acquisition protocol for the Siemens scanner determined, clinicians visually graded the images to identify optimal reconstruction parameters.ResultsIn the first matched patient study, the mean percentage difference in CTDIvol for Siemens compared to GE was − 10.7% (range − 41.7 to 50.1%), and the mean percentage difference in noise measured in the patients’ liver was 7.6% (range − 31.0 to 76.8%). In the second matched patient study, the mean percentage difference in CTDIvol for Siemens compared to GE was − 20.5% (range − 43.1 to 1.9%), and the mean percentage difference in noise was 19.8% (range − 27.0 to 146.8%). For these patients, the mean SSDEs for patients scanned on the Siemens and GE scanners were 3.27 (range 2.83 to 4.22) mGy and 4.09 (range 2.81 to 4.82) mGy, respectively. The analysis of the visual grading study indicated no preference for any of the SAFIRE strengths.ConclusionsGiven the different implementations of acquisition parameters and reconstruction algorithms between vendors, careful consideration is required to ensure optimisation and standardisation of protocols.
Journal Article