Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
1 result(s) for "Cranke Gary"
Sort by:
Electrical synchronization achieved by multipoint pacing combined with dynamic atrioventricular delay
PurposeMultipoint pacing (MPP) improves left ventricular (LV) electrical synchrony in cardiac resynchronization therapy (CRT). SyncAV automatically adjusts atrioventricular delay (AVD) according to intrinsic AV intervals and may further improve synchrony. Their combination has not been assessed. The objective was to evaluate the improvement in electrical synchrony achieved by SyncAV combined with MPP in an international, multicenter study.MethodsPatients with LBBB undergoing CRT implant with a quadripolar lead (Abbott Quartet™) were prospectively enrolled. QRS duration (QRSd) was measured by blinded observers from 12-lead ECG during: intrinsic conduction, BiV pacing (conventional biventricular pacing, nominal static AVD), MPP (2 LV cathodes maximally spaced, nominal static AVD), BiV + SyncAV, and MPP + SyncAV. All SyncAV offsets were individualized for each patient to yield the narrowest QRSd during BiV pacing. QRSd changes were compared by ANOVA and post hoc Tukey-Kramer tests.ResultsOne hundred and three patients were enrolled (65.7 ± 12.1 years, 67% male, 37% ischemic, EF 26.4 ± 6.5%, PR 190.3 ± 39.1 ms). Relative to intrinsic conduction (QRSd of 165 ± 16 ms), BiV reduced QRSd by 11.9% to 145 ± 18 ms (P < 0.001 vs intrinsic), and MPP reduced QRSd by 13.3% to 142 ± 19 ms (P < 0.001 vs intrinsic). However, enabling SyncAV with a patient-optimized offset nearly doubled this QRSd reduction. BiV + SyncAV reduced QRSd by 22.0% to 128 ± 13 ms (P < 0.001 vs BiV), while MPP + SyncAV reduced QRSd further by 25.6% to 122 ± 14 ms (P < 0.05 vs BiV + SyncAV).ConclusionSyncAV can significantly improve acute electrical synchrony beyond conventional CRT, with further improvement achieved by superimposing MPP.