Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
92 result(s) for "Del Din, Silvia"
Sort by:
Entropy of Real-World Gait in Parkinson’s Disease Determined from Wearable Sensors as a Digital Marker of Altered Ambulatory Behavior
Parkinson’s disease (PD) is a common age-related neurodegenerative disease. Gait impairment is frequent in the later stages of PD contributing to reduced mobility and quality of life. Digital biomarkers such as gait velocity and step length are predictors of motor and cognitive decline in PD. Additional gait parameters may describe different aspects of gait and motor control in PD. Sample entropy (SampEnt), a measure of signal predictability, is a nonlinear approach that quantifies regularity of a signal. This study investigated SampEnt as a potential biomarker for PD and disease duration. Real-world gait data over a seven-day period were collected using an accelerometer (Axivity AX3, York, UK) placed on the low back and gait metrics extracted. SampEnt was determined for the stride time, with vector length and threshold parameters optimized. People with PD had higher stride time SampEnt compared to older adults, indicating reduced gait regularity. The range of SampEnt increased over 36 months for the PD group, although the mean value did not change. SampEnt was associated with dopaminergic medication dose but not with clinical motor scores. In conclusion, this pilot study indicates that SampEnt from real-world data may be a useful parameter reflecting clinical status although further research is needed involving larger populations.
Turning Detection During Gait: Algorithm Validation and Influence of Sensor Location and Turning Characteristics in the Classification of Parkinson’s Disease
Parkinson’s disease (PD) is a common neurodegenerative disorder resulting in a range of mobility deficits affecting gait, balance and turning. In this paper, we present: (i) the development and validation of an algorithm to detect turns during gait; (ii) a method to extract turn characteristics; and (iii) the classification of PD using turn characteristics. Thirty-seven people with PD and 56 controls performed 180-degree turns during an intermittent walking task. Inertial measurement units were attached to the head, neck, lower back and ankles. A turning detection algorithm was developed and validated by two raters using video data. Spatiotemporal and signal-based characteristics were extracted and used for PD classification. There was excellent absolute agreement between the rater and the algorithm for identifying turn start and end (ICC ≥ 0.99). Classification modeling (partial least square discriminant analysis (PLS-DA)) gave the best accuracy of 97.85% when trained on upper body and ankle data. Balanced sensitivity (97%) and specificity (96.43%) were achieved using turning characteristics from the neck, lower back and ankles. Turning characteristics, in particular angular velocity, duration, number of steps, jerk and root mean square distinguished mild-moderate PD from controls accurately and warrant future examination as a marker of mobility impairment and fall risk in PD.
Gait Analysis with Wearables Can Accurately Classify Fallers from Non-Fallers: A Step toward Better Management of Neurological Disorders
Falls are the leading cause of mortality, morbidity and poor quality of life in older adults with or without neurological conditions. Applying machine learning (ML) models to gait analysis outcomes offers the opportunity to identify individuals at risk of future falls. The aim of this study was to determine the effect of different data pre-processing methods on the performance of ML models to classify neurological patients who have fallen from those who have not for future fall risk assessment. Gait was assessed using wearables in clinic while walking 20 m at a self-selected comfortable pace in 349 (159 fallers, 190 non-fallers) neurological patients. Six different ML models were trained on data pre-processed with three techniques such as standardisation, principal component analysis (PCA) and path signature method. Fallers walked more slowly, with shorter strides and longer stride duration compared to non-fallers. Overall, model accuracy ranged between 48% and 98% with 43–99% sensitivity and 48–98% specificity. A random forest (RF) classifier trained on data pre-processed with the path signature method gave optimal classification accuracy of 98% with 99% sensitivity and 98% specificity. Data pre-processing directly influences the accuracy of ML models for the accurate classification of fallers. Using gait analysis with trained ML models can act as a tool for the proactive assessment of fall risk and support clinical decision-making.
An Objective Methodology for the Selection of a Device for Continuous Mobility Assessment
Continuous monitoring by wearable technology is ideal for quantifying mobility outcomes in “real-world” conditions. Concurrent factors such as validity, usability, and acceptability of such technology need to be accounted for when choosing a monitoring device. This study proposes a bespoke methodology focused on defining a decision matrix to allow for effective decision making. A weighting system based on responses (n = 69) from a purpose-built questionnaire circulated within the IMI Mobilise-D consortium and its external collaborators was established, accounting for respondents’ background and level of expertise in using wearables in clinical practice. Four domains (concurrent validity, CV; human factors, HF; wearability and usability, WU; and data capture process, CP), associated evaluation criteria, and scores were established through literature research and group discussions. While the CV was perceived as the most relevant domain (37%), the others were also considered highly relevant (WU: 30%, HF: 17%, CP: 16%). Respondents (~90%) preferred a hidden fixation and identified the lower back as an ideal sensor location for mobility outcomes. Overall, this study provides a novel, holistic, objective, as well as a standardized approach accounting for complementary aspects that should be considered by professionals and researchers when selecting a solution for continuous mobility monitoring.
Gait Asymmetry Post-Stroke: Determining Valid and Reliable Methods Using a Single Accelerometer Located on the Trunk
Asymmetry is a cardinal symptom of gait post-stroke that is targeted during rehabilitation. Technological developments have allowed accelerometers to be a feasible tool to provide digital gait variables. Many acceleration-derived variables are proposed to measure gait asymmetry. Despite a need for accurate calculation, no consensus exists for what is the most valid and reliable variable. Using an instrumented walkway (GaitRite) as the reference standard, this study compared the validity and reliability of multiple acceleration-derived asymmetry variables. Twenty-five post-stroke participants performed repeated walks over GaitRite whilst wearing a tri-axial accelerometer (Axivity AX3) on their lower back, on two occasions, one week apart. Harmonic ratio, autocorrelation, gait symmetry index, phase plots, acceleration, and jerk root mean square were calculated from the acceleration signals. Test–retest reliability was calculated, and concurrent validity was estimated by comparison with GaitRite. The strongest concurrent validity was obtained from step regularity from the vertical signal, which also recorded excellent test–retest reliability (Spearman’s rank correlation coefficients (rho) = 0.87 and Intraclass correlation coefficient (ICC21) = 0.98, respectively). Future research should test the responsiveness of this and other step asymmetry variables to quantify change during recovery and the effect of rehabilitative interventions for consideration as digital biomarkers to quantify gait asymmetry.
Classification of Neurological Patients to Identify Fallers Based on Spatial-Temporal Gait Characteristics Measured by a Wearable Device
Neurological patients can have severe gait impairments that contribute to fall risks. Predicting falls from gait abnormalities could aid clinicians and patients mitigate fall risk. The aim of this study was to predict fall status from spatial-temporal gait characteristics measured by a wearable device in a heterogeneous population of neurological patients. Participants (n = 384, age 49–80 s) were recruited from a neurology ward of a University hospital. They walked 20 m at a comfortable speed (single task: ST) and while performing a dual task with a motor component (DT1) and a dual task with a cognitive component (DT2). Twenty-seven spatial-temporal gait variables were measured with wearable sensors placed at the lower back and both ankles. Partial least square discriminant analysis (PLS-DA) was then applied to classify fallers and non-fallers. The PLS-DA classification model performed well for all three gait tasks (ST, DT1, and DT2) with an evaluation of classification performance Area under the receiver operating characteristic Curve (AUC) of 0.7, 0.6 and 0.7, respectively. Fallers differed from non-fallers in their specific gait patterns. Results from this study improve our understanding of how falls risk-related gait impairments in neurological patients could aid the design of tailored fall-prevention interventions.
Free-living gait characteristics in ageing and Parkinson’s disease: impact of environment and ambulatory bout length
Background Gait is emerging as a powerful diagnostic and prognostic tool, and as a surrogate marker of disease progression for Parkinson’s disease (PD). Accelerometer-based body worn monitors (BWMs) facilitate the measurement of gait in clinical environments. Moreover they have the potential to provide a more accurate reflection of gait in the home during habitual behaviours. Emerging research suggests that measurement of gait using BWMs is feasible but this has not been investigated in depth. The aims of this study were to explore (i) the impact of environment and (ii) ambulatory bout (AB) length on gait characteristics for discriminating between people with PD and age-matched controls. Methods Fourteen clinically relevant gait characteristics organised in five domains (pace, variability, rhythm, asymmetry, postural control) were quantified using laboratory based and free-living data collected over 7 days using a BWM placed on the lower back in 47 PD participants and 50 controls. Results Free-living data showed that both groups walked with decreased pace and increased variability, rhythm and asymmetry compared to walking in the laboratory setting. Four of the 14 gait characteristics measured in free-living conditions were significantly different between controls and people with PD compared to two measured in the laboratory. Between group differences depended on bout length and were more apparent during longer ABs. ABs ≤ 10s did not discriminate between groups. Medium to long ABs highlighted between-group significant differences for pace, rhythm and asymmetry. Longer ABs should therefore be taken into account when evaluating gait characteristics in free-living conditions. Conclusion This study provides encouraging results to support the use of a single BWM for free-living gait evaluation in people with PD with potential for research and clinical application.
Real-World Wrist-Derived Digital Mobility Outcomes in People with Multiple Long-Term Conditions: A Comparison of Algorithms
Digital Mobility outcomes can serve as objective biomarkers of health, but their validation in populations with multiple long-term conditions (MLTCs) based on wrist-worn devices remains unexplored. We refined, improved, and introduced novel algorithms, specifically tailored and adapted for (i) gait sequence detection, (ii) initial contact identification, and (iii) stride length estimation from a single wrist-worn device. Validation was performed using data from 28 participants with co-occurring MLTCs performing a 2.5 h real-world monitoring session. Reference data from an established multi-sensor system were used to assess algorithm performance across diverse gait patterns of co-occurring MLTCs. Twenty-eight participants (mean age 70.4 years, 43% females) had a median of three co-occurring MLTCs. Among six gait sequence detection methods, improved versions of the Kheirkhahan algorithm performed best (accuracy = 0.92, specificity = 0.96). For initial contact detection (nine methods tested), Shin’s algorithm achieved the highest performance index (0.85) followed by McCamley (0.84). Stride length estimation was most accurate using novel approaches based on the Weinberg method (performance index > 0.70). The proposed fine-tuned algorithms, the newly developed adaptive variants, and the foot-length augmented versions demonstrated robust performance, surpassing many existing methods and addressing the complexity of gait patterns in MLTCs. These findings enable scalable, real-time mobility monitoring in complex clinical populations using accessible wearable technology.
How can we improve Comprehensive Geriatric Assessment for older people living with frailty in primary care and community settings? A qualitative study
ObjectiveWith advancing age comes the increasing prevalence of frailty and increased risk of adverse outcomes (eg, hospitalisation). Evidence for comprehensive geriatric assessment (CGA), a multidimensional holistic model of care, is mixed in community settings. Uncertainties remain, such as the key components of CGA, who delivers it, and the use of technology. This study aimed to understand the perspectives, beliefs and experiences, of both older people and health professionals, to improve the current CGA and explore factors that may impact on CGA delivery in community settings.DesignA qualitative interview study was conducted with older people and healthcare professionals (HCPs) identified using a maximum variation strategy. Data were analysed using an abductive analysis approach. The non-adoption, abandonment, scale-up, spread and sustainability framework and the theoretical framework of acceptability guided the categorisation of the codes and identified categories were mapped to the two frameworks.SettingEngland, UK.Results27 people were interviewed, constituting 14 older people and 13 HCPs. We identified limitations in the current CGA: a lack of information sharing between different HCPs who deliver CGA; poor communication between older people and their HCPs and a lack of follow-up as part of CGA. When we discussed the potential for CGA to use technology, HCPs and older people varied in their readiness to engage with it.ConclusionsViable solutions to address gaps in the current delivery of CGA include the provision of training and support to use digital technology and a designated comprehensive care coordinator. The next stage of this research will use these findings, existing evidence and stakeholder engagement, to develop and refine a model of community-based CGA that can be assessed for feasibility and acceptability.