Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
26
result(s) for
"Derval, Nicolas"
Sort by:
Fast Simulation of Mechanical Heterogeneity in the Electrically Asynchronous Heart Using the MultiPatch Module
by
Walmsley, John
,
Prinzen, Frits W.
,
Delhaas, Tammo
in
Algorithms
,
Animals
,
Bundle-Branch Block - complications
2015
Cardiac electrical asynchrony occurs as a result of cardiac pacing or conduction disorders such as left bundle-branch block (LBBB). Electrically asynchronous activation causes myocardial contraction heterogeneity that can be detrimental for cardiac function. Computational models provide a tool for understanding pathological consequences of dyssynchronous contraction. Simulations of mechanical dyssynchrony within the heart are typically performed using the finite element method, whose computational intensity may present an obstacle to clinical deployment of patient-specific models. We present an alternative based on the CircAdapt lumped-parameter model of the heart and circulatory system, called the MultiPatch module. Cardiac walls are subdivided into an arbitrary number of patches of homogeneous tissue. Tissue properties and activation time can differ between patches. All patches within a wall share a common wall tension and curvature. Consequently, spatial location within the wall is not required to calculate deformation in a patch. We test the hypothesis that activation time is more important than tissue location for determining mechanical deformation in asynchronous hearts. We perform simulations representing an experimental study of myocardial deformation induced by ventricular pacing, and a patient with LBBB and heart failure using endocardial recordings of electrical activation, wall volumes, and end-diastolic volumes. Direct comparison between simulated and experimental strain patterns shows both qualitative and quantitative agreement between model fibre strain and experimental circumferential strain in terms of shortening and rebound stretch during ejection. Local myofibre strain in the patient simulation shows qualitative agreement with circumferential strain patterns observed in the patient using tagged MRI. We conclude that the MultiPatch module produces realistic regional deformation patterns in the asynchronous heart and that activation time is more important than tissue location within a wall for determining myocardial deformation. The CircAdapt model is therefore capable of fast and realistic simulations of dyssynchronous myocardial deformation embedded within the closed-loop cardiovascular system.
Journal Article
Prevalence and Prognostic Role of Various Conduction Disturbances in Patients With the Brugada Syndrome
by
Haïssaguerre, Michel
,
Cardin, Christelle
,
Delay, Marc
in
Brugada Syndrome - complications
,
Brugada Syndrome - epidemiology
,
Brugada Syndrome - physiopathology
2013
Prevalence and prognostic value of conduction disturbances in patients with the Brugada syndrome (BrS) remains poorly known. Electrocardiograms (ECGs) from 325 patients with BrS (47 ± 13 years, 258 men) with spontaneous (n = 143) or drug-induced (n = 182) type 1 ECG were retrospectively reviewed. Two hundred twenty-six patients (70%) were asymptomatic, 73 patients (22%) presented with unexplained syncope, and 26 patients (8%) presented with sudden death or implantable cardioverter-defibrillator appropriated therapies at diagnosis or during a mean follow-up of 48 ± 34 months. P-wave duration of ≥120 ms was present in 129 patients (40%), first degree atrioventricular block (AVB) in 113 (35%), right bundle branch block (BBB) in 90 (28%), and fascicular block in 52 (16%). Increased P-wave duration, first degree AVB, and right BBB were more often present in patients after drug challenge than in patients with spontaneous type 1 ST elevation. Left BBB was present in 3 patients. SCN5A mutation carriers had longer P-wave duration and longer PR and HV intervals. In multivariate analysis, first degree AVB was independently associated with sudden death or implantable cardioverter-defibrillator appropriated therapies (odds ratio 2.41, 95% confidence interval 1.01 to 5.73, p = 0.046) together with the presence of syncope and spontaneous type 1 ST elevation. In conclusion, conduction disturbances are frequent and sometimes diffuse in patients with BrS. First degree AVB is independently linked to outcome and may be proposed to be used for individual risk stratification.
Journal Article
Evaluation and optimization of novel extraction algorithms for the automatic detection of atrial activations recorded within the pulmonary veins during atrial fibrillation
by
Pascale, Patrizio
,
Roten, Laurent
,
Luca, Adrian
in
Ablation
,
Activation detection
,
Adaptive algorithms
2022
Background and objective
The automated detection of atrial activations (AAs) recorded from intracardiac electrograms (IEGMs) during atrial fibrillation (AF) is challenging considering their various amplitudes, morphologies and cycle length. Activation time estimation is further complicated by the constant changes in the IEGM active zones in complex and/or fractionated signals. We propose a new method which provides reliable automatic extraction of intracardiac AAs recorded within the pulmonary veins during AF and an accurate estimation of their local activation times.
Methods
First, two recently developed algorithms were evaluated and optimized on 118 recordings of pulmonary vein IEGM taken from 35 patients undergoing ablation of persistent AF. The adaptive mathematical morphology algorithm (AMM) uses an adaptive structuring element to extract AAs based on their morphological features. The relative-energy algorithm (Rel-En) uses short- and long-term energies to enhance and detect the AAs in the IEGM signals. Second, following the AA extraction, the signal amplitude was weighted using statistics of the AA sequences in order to reduce over- and undersensing of the algorithms. The detection capacity of our algorithms was compared with manually annotated activations and with two previously developed algorithms based on the Teager–Kaiser energy operator and the AF cycle length iteration, respectively. Finally, a method based on the barycenter was developed to reduce artificial variations in the activation annotations of complex IEGM signals.
Results
The best detection was achieved using Rel-En, yielding a false negative rate of 0.76% and a false positive rate of only 0.12% (total error rate 0.88%) against expert annotation. The post-processing further reduced the total error rate of the Rel-En algorithm by 70% (yielding to a final total error rate of 0.28%).
Conclusion
The proposed method shows reliable detection and robust temporal annotation of AAs recorded within pulmonary veins in AF. The method has low computational cost and high robustness for automatic detection of AAs, which makes it a suitable approach for online use in a procedural context.
Journal Article
Ante-mortem characterization of sudden deaths as first-manifestation in Italy
2022
PurposeThere is a relative paucity of data on ante-mortem clinical characteristics of young (age 1 to 35 years) sudden death (SD) victims. The aim of the study was to characterize ante-mortem characteristics of SD victims, in a selected national cohort identified by a web search.MethodsA dataset of all SD (January 2010 and December 2015) was built from national forensic data and medical records, integrated with Google search model. Families were contacted to obtain consent for interviews. Data were obtained on ante-mortem symptoms. ECG characteristics and autopsy data were available.ResultsOut of 301 SD cases collected, medical and family history was available in 132 (43.9%). Twenty-eight (21.1%) had a positive family history for SD. SD occurred during sport/effort in 76 (57.6%). One hundred twelve (85%) SD cases had no prior reported symptoms. Autopsy data were available in 100/132 (75.8%) cases: an extra cardiac cause was identified in 20 (20%). Among the 61 cases with a cardiac diagnosis, 21 (34%) had hypertrophic cardiomyopathy. Among the 19 (19%) victims without structural abnormalities, molecular autopsy identified pathogenic variants for channelopathies in 9 cases. Ten (10%) victims had no identifiable cause.ConclusionsMost SD were due to cardiac causes and occurred in previously asymptomatic patients. SD events mainly occurred during strenuous activity. In a minority of cases, no cause was identified. The web-based selection criteria, and incomplete data retrieval, need to be carefully taken into account for data interpretation and reproducibility.
Journal Article
Persistent atrial fibrillation ablation: conventional versus driver-guided strategy
by
Shah, Ashok J
,
Haïssaguerre, Michel
,
Lim, Han S
in
Ablation
,
atrial fibrillation
,
Cardiac arrhythmia
2015
While pulmonary vein isolation for paroxysmal atrial fibrillation (AF) is highly effective, catheter ablation for persistent AF remains a challenge with varying clinical success reported. Several ablation techniques have been proposed to target persistent AF, with the additional ablation of complex fractionated electrograms and linear lesions shown to provide incremental success to pulmonary vein isolation alone. Recently, several studies have suggested the presence of localized drivers (re-entrant or focal) in AF. By targeting these drivers, clinical outcomes may be maintained while minimizing the extent of ablation. This article will focus on the conventional stepwise ablation approach for persistent AF versus driver-guided ablation with the use of newer mapping technologies.
Journal Article
Sudden Cardiac Arrest Associated with Early Repolarization
by
Haïssaguerre, Michel
,
Scanu, Patrice
,
Lavergne, Thomas
in
Actuarial Analysis
,
Adult
,
Anti-Arrhythmia Agents - therapeutic use
2008
An electrocardiographic pattern of early repolarization (elevation of the QRS–ST junction) is generally believed to be benign. In this study, however, researchers found that among case subjects with idiopathic ventricular fibrillation, the prevalence of early repolarization was significantly increased, as compared with that among control subjects. These findings will lead to a reconsideration of the clinical significance of early repolarization.
Researchers found that among case subjects with idiopathic ventricular fibrillation, the prevalence of early repolarization was significantly increased. These findings will lead to a reconsideration of the clinical significance of early repolarization.
Sudden cardiac arrest remains a major public health problem that accounts for approximately 350,000 deaths annually in the United States. Despite advances in emergency medical systems, only 3 to 10% of patients who have an out-of-hospital cardiac arrest are successfully resuscitated. The majority of such sudden cardiac arrests are caused by ventricular tachyarrhythmias, which occur in persons without structural heart disease in 6 to 14% of cases.
1
,
2
Some of the latter cases are related to well-recognized electrocardiographic abnormalities that affect ventricular repolarization (e.g., long or short QT intervals or the Brugada syndrome), whereas other cases, in which there are . . .
Journal Article
2024 European Heart Rhythm Association/Heart Rhythm Society/Asia Pacific Heart Rhythm Society/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation
by
Merino, Jose Luis
,
Nitta, Takashi
,
Duytschaever, Mattias
in
Ablation
,
Arrhythmia
,
Cardiac arrhythmia
2024
In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.
Journal Article
Advanced Imaging Integration for Catheter Ablation of Ventricular Tachycardia
by
Haïssaguerre, Michel
,
Ly, Buntheng
,
Bordachar, Pierre
in
Ablation
,
Arrhythmias, Cardiac
,
Blood clots
2023
Purpose of Review
Imaging plays a crucial role in the therapy of ventricular tachycardia (VT). We offer an overview of the different methods and provide information on their use in a clinical setting.
Recent Findings
The use of imaging in VT has progressed recently. Intracardiac echography facilitates catheter navigation and the targeting of moving intracardiac structures. Integration of pre-procedural CT or MRI allows for targeting the VT substrate, with major expected impact on VT ablation efficacy and efficiency. Advances in computational modeling may further enhance the performance of imaging, giving access to pre-operative simulation of VT. These advances in non-invasive diagnosis are increasingly being coupled with non-invasive approaches for therapy delivery.
Summary
This review highlights the latest research on the use of imaging in VT procedures. Image-based strategies are progressively shifting from using images as an adjunct tool to electrophysiological techniques, to an integration of imaging as a central element of the treatment strategy.
Journal Article
2024 European Heart Rhythm Association/Heart Rhythm Society/Asia Pacific Heart Rhythm Society/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation
by
Merino, Jose Luis
,
Nitta, Takashi
,
Gerstenfeld, Edward P.
in
Ablation
,
Ablation (Surgery)
,
Antiarrhythmics
2024
In the last three decades, ablation of atrial fibrillation (AF) has become an evidence‐based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society
Journal Article
Anatomical Treatment Strategies for Persistent Atrial Fibrillation with Ethanol Infusion within the Vein of Marshall—Current Challenges and Future Directions
by
Haïssaguerre, Michel
,
Bouyer, Benjamin
,
Mené, Roberto
in
Ablation
,
Ablation (Surgery)
,
Atrial fibrillation
2024
Currently, pulmonary vein isolation (PVI) is the gold standard in catheter ablation for atrial fibrillation (AF). However, PVI alone may be insufficient in the management of persistent AF, and complementary methods are being explored. One such method takes an anatomical approach—improving both its success rate and lesion durability may lead to improved treatment outcomes. An additional approach complementary to the anatomical one is also attracting attention, one that focuses on epicardial conduction. This involves ethanol ablation of the vein of Marshall (VOM) and can be very effective in blocking epicardial conduction related to Marshall structure; it is becoming incorporated into standard treatment. However, the pitfall of this “Marshall-PLAN”, a method that combines an anatomical approach with ethanol infusion within the VOM (Et-VOM), is that Et-VOM and other line creations are not always successfully completed. This has led to cases of AF and/or atrial tachycardia (AT) recurrence even after completing this lesion set. Investigating effective adjunctive methods will enable us to complete the lesion set with the aim to lower the rates of recurrence of AF and/or AT in the future.
Journal Article