Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Series Title
      Series Title
      Clear All
      Series Title
  • Reading Level
      Reading Level
      Clear All
      Reading Level
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Content Type
    • Item Type
    • Is Full-Text Available
    • Subject
    • Publisher
    • Source
    • Donor
    • Language
    • Place of Publication
    • Contributors
    • Location
34 result(s) for "Dobbelsteen, Andy van den"
Sort by:
Sustainable energy landscapes : designing, planning, and development
\"With experts from different related fields discussing their approaches to energy-conscious planning and design, this comprehensive book presents state-of-the-art research, education, and design practice with respect to sustainable energy landscapes. It also addresses how to quantify the impact of energy transition both on landscape quality and energy economy, issues of growing importance. Focusing on the municipal and regional scale, where energy-conscious interventions are effective and stakeholders can participate actively in the transition process, the text illustrates practical applications of emerging methods using case studies from across the globe\"-- Provided by publisher.
Moving Beyond Diesel Generators: Exploring Renewable Backup Alternatives for Data Centers
This study investigates sustainable alternatives to diesel generators for data centre backup power, focusing on renewable diesel (HVO), Hydrogen energy storage (HES), batteries (Lithium-ion and Sodium Sulfur) and Compressed Air Energy Storage (CAES). As environmental scrutiny of data centres grows, the need for cleaner energy sources intensifies. Our research assesses various storage technologies’ energy performance metrics, environmental impacts, and economic feasibility. HVO is a seamless substitute for conventional diesel, compatible with existing infrastructure and less carbon-intensive. CAES offers lower life cycle emissions and operational costs but is geographically dependent. While currently more costly, batteries could achieve better economics with increased operational hours. However, extending the backup duration increases their capital and operating costs significantly, which is less advantageous than other technologies, where only fuel costs increase with longer backup times. For existing data centres transitioning to sustainable energy, HVO is optimal; for new facilities, CAES is ideal if geography allows, with HES as a robust alternative. This analysis offers a pathway for data centres to adopt sustainable, cost-effective energy storage solutions and reduce carbon footprints through on-site renewables or green energy procurement.
Correction: Medici et al. Safety and Health Concerns for the Users of a Playground, Built with Reused Rotor Blades from a Dismantled Wind Turbine. Sustainability 2020, 12, 3626
In a few interviews after the paper’s publication, Superuse Studios declared that it would be appropriate and relevant to specify that they commissioned the initial research from where this research paper derives and that they provided a solution regarding one of the main issues after the commissioned research and before the publication of this research paper [...]
A Parametric Modelling Approach for Energy Retrofitting Heritage Buildings: The Case of Amsterdam City Centre
The city of Amsterdam has ambitious goals to achieve a 95% reduction in carbon emissions by 2050 and to phase out natural gas by 2040. Disconnecting the building stock from natural gas requires well-ventilated and well-insulated buildings and a switch to renewable energy sources, making optimal use of heat pumps and sustainable heating solutions available locally. Most buildings in the historical city centre are protected and often insufficiently insulated, leading to increased energy use and a poor thermal environment. Standard retrofitting interventions may be restricted, requiring new approaches to balancing the need for energy efficiency and the preservation of heritage significance. With the case of the Amsterdam City Centre, the goal of this research is to present a parametric modelling approach for energy retrofitting heritage buildings and to identify minimum requirements for preparing the residential stock to lower temperature heat (LTH). Using parametric design and bottom-up energy modelling, the research estimates that a 69.1% of natural gas reduction could be achieved when upgrading the buildings to lower temperature (LT). Results of this paper also demonstrate how the applied approach can be used to guide decisions on the improvement in energy performance of the historic built environment.
Safety and Health Concerns for the Users of a Playground, Built with Reused Rotor Blades from a Dismantled Wind Turbine
This paper analyses the user safety of a playground built out of reused blades from a dismantled wind turbine. Located in Rotterdam and designed by the Netherlands architecture firm Superuse Studios, the playground, called “Wikado”, represents an example of the circular economy applied to the built environment. With reused materials, Wikado represents a saving in resources and energy, when compared to a standard playground built with primary materials. Furthermore, the playground creates a unique design experience for its users, who can still recognise the original rotor blades following their transformation into slides, platforms, and tunnels. However, the safety of the playground could be questioned. This paper will analyse the materials and products used in the playground and their condition some years after opening. The analysis focuses on the risks of human health during the use of the playground. It considers the shape and the sharpness of the rotor blades, its components such as glass fibres and epoxy resin. As a result of the analysis, two risk analysis conceptual models help to assess the health concerns regarding the contact with the materials, and some yellow drops leaching from the rotor blades. This analysis informs the contemporary debate concerning the reuse of materials, and more generically, the circular economy applied to the built environment: whether it is recommended and safe to reuse materials for a different function from that which they were originally designed. This paper will explain that in the analysed case study, it can be safe to reuse materials for a different function, but only with the appropriate precautions.
Early-Stage Design Considerations for the Energy-Efficiency of High-Rise Office Buildings
Decisions made at early stages of the design are of the utmost importance for the energy-efficiency of buildings. Wrong decisions and design failures related to a building’s general layout, shape, façade transparency or orientation can increase the operational energy tremendously. These failures can be avoided in advance through simple changes in the design. Using extensive parametric energy simulations by DesignBuilder, this paper investigates the impact of geometric factors for the energy-efficiency of high-rise office buildings in three climates contexts: Amsterdam (Temperate), Sydney (Sub-tropical) and Singapore (Tropical). The investigation is carried out on 12 plan shapes, 7 plan depths, 4 building orientations and discrete values for window-to-wall ratio. Among selected options, each sub-section determines the most efficient solution for different design measures and climates. The optimal design solution is the one that minimises, on an annual basis, the sum of the energy use for heating, cooling, electric lighting and fans. The results indicate that the general building design is an important issue to consider for high-rise buildings: they can influence the energy use up to 32%. For most of the geometric factors, the greatest difference between the optimal and the worst solution occurs in the sub-tropical climate, while the tropical climate is the one that shows the smallest difference. In case of the plan depth, special attention should be paid in the case of a temperate climate, as the total energy use can increase more than in other climates. Regarding energy performance, the following building geometry factors have the highest to lowest influence: building orientation, plan shape, plan depth, and window-to-wall ratio.
Synergetic integration of vertical farms and buildings: reducing the use of energy, water, and nutrients
Vertical farms use some resources very efficiently. However, their electricity use is considerable, and a significant amount of waste heat is produced. This paper investigates how the integration of vertical farms in buildings could reduce the use of energy, water, and nutrients collectively across both entities by leveraging potential resource synergies. The paper considered the integration of vertical farms in apartments, offices, restaurants, swimming pools, and supermarkets located in the Netherlands. For each typology, the floor area heated and the amount of building users fed by one m 2 of one production layer within the vertical farm was calculated, along with required outputs of water and nutrients from the building to sustain the vertical farm. The energy savings of different integration strategies were calculated for each building typology in comparison to a non-integrated approach. Results showed that the synergetic integration of vertical farms with buildings reduced the year-round energy use of the climate systems of both entities collectively by between 12 and 51%. The integration of vertical farms with buildings decreases the use of energy, water, and nutrients from external sources and offers great potentials to reduce the environmental impacts of both entities, whilst producing food in urban environments.
Effects of Architectural Space Layouts on Energy Performance: A Review
As one of the most important design tasks of building design, space layout design affects the building energy performance (BEP). In order to investigate the effect, a literature review of relevant papers was performed. Ten relevant articles were found and reviewed in detail. First, a methodology for studying the effects of space layouts on BEP were proposed regarding design variables, energy indicators and BEP calculation methods, and the methodologies used in the 10 articles were reviewed. Then, the effects of space layouts on energy use and occupant comfort were analysed separately. The results show that the energy use for heating, cooling, lighting and ventilation is highly affected by space layouts, as well as thermal and visual comfort. The effects of space layouts on energy use are higher than on occupant comfort. By changing space layouts, the resulting reductions in the annual final energy for heating and cooling demands were up to 14% and 57%, respectively, in an office building in Sweden. The resulting reductions in the lighting demand of peak summer and winter were up to 67% and 43%, respectively, for the case of an office building in the UK, and the resulting reduction in the air volume supplied by natural ventilation was 65%. The influence of other design parameters, i.e., occupancy and window to wall ratio, on the effects of space layouts on BEP was also identified.
The Effect of Geometry Parameters on Energy and Thermal Performance of School Buildings in Cold Climates of China
This paper discusses the role of geometry parameters including building shape, window to wall ratio, room depth, and orientation on the energy use and thermal comfort of school buildings in cold climates of China. The annual total energy demand and summer thermal discomfort time were compared through computer simulations with DesignBuilder. Furthermore, a questionnaire was conducted that related to the students’ subjective preference for various building geometry parameters. Results showed that a maximum of 13.6% of energy savings and 3.8% of thermal comfort improvement when compared to the reference case could be achieved through variations in geometry parameters. The H shape performed the best when the building thermal performance and students’ preferences were considered, as well as the various design options for architects. Window to wall ratio, room depth, and orientation should also be carefully addressed in terms of different building types. The results of this study can serve as a reference for architects and school managers in the early design stages of schools in cold climates of China.
Relationship Analysis and Optimisation of Space Layout to Improve the Energy Performance of Office Buildings
Architectural space layout has proven to be influential on building energy performance. However, the relationship between different space layouts and their consequent energy demands has not yet been systematically studied. This study thoroughly investigates such a relationship. In order to do so, a computational method was developed, which includes a method to generate space layouts featuring energy-related variables and an assessment method for energy demand. Additionally, a design of experiments was performed, and its results were used to analyse the relationship between space layouts and energy demands. In order to identify their relationship, four types of design indicators of space layout were proposed, both for the overall layout and for each function. Finally, several optimisations were performed to minimise heating, cooling and lighting demands. The optimisation results showed that the maximum reduction between different layouts was up to 54% for lighting demand, 51% for heating demand and 38% for cooling demand. The relationship analysis shows that when comparing the four types of design indicators, the façade area-to-floor area ratio showed a stronger correlation with energy demands than the façade area ratio, floor area ratio and height-to-depth ratio. Overall, this study shows that designing a space layout helps to reduce energy demands for heating, cooling and lighting, and also provides a reference for other researchers and designers to optimise space layout with improved energy performance.