Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
49 result(s) for "Doelling, D."
Sort by:
In-Flight Calibration and Performance of the OSIRIS-REx Touch And Go Camera System (TAGCAMS)
The Touch And Go Camera System (TAGCAMS) is a three-camera-head instrument onboard NASA’s OSIRIS-REx asteroid sample return mission spacecraft. The purpose of TAGCAMS is to facilitate navigation to the target asteroid, (101955) Bennu; confirm acquisition of the asteroid sample; document asteroid sample stowage; and provide supplementary imaging for OSIRIS-REx science investigations. During the almost two-year OSIRIS-REx outbound cruise phase we pursued nine TAGCAMS imaging campaigns to check, calibrate and characterize the camera system’s performance before asteroid arrival and proximity operations began in late 2018. The TAGCAMS in-flight calibration dataset provides the relevant information to enable the three cameras to complete their primary observation goals during asteroid operations. The key performance parameters that we investigated in flight included: linearity, responsivity (both point source and extended body), dark current, hot pixels, pointing, image geometry transformation, image quality and stray light. Analyses of the in-flight performance either confirmed the continued applicability of the TAGCAMS ground test results or substantially improved upon the ground test knowledge. In addition, the TAGCAMS calibration observations identified the source of a spacecraft outgassing feature that guided successful remediation efforts prior to asteroid arrival.
THE GLOBAL SPACE-BASED INTER-CALIBRATION SYSTEM
The Global Space-based Inter-Calibration System (GSICS) is a new international program to assure the comparability of satellite measurements taken at different times and locations by different instruments operated by different satellite agencies. Sponsored by the World Meteorological Organization and the Coordination Group for Meteorological Satellites, GSICS will intercalibrate the instruments of the international constellation of operational low-earth-orbiting (LEO) and geostationary earth-orbiting (GEO) environmental satellites and tie these to common reference standards. The intercomparability of the observations will result in more accurate measurements for assimilation in numerical weather prediction models, construction of more reliable climate data records, and progress toward achieving the societal goals of the Global Earth Observation System of Systems. GSICS includes globally coordinated activities for prelaunch instrument characterization, onboard routine calibration, sensor intercomparison of near-simultaneous observations of individual scenes or overlapping time series, vicarious calibration using Earth-based or celestial references, and field campaigns. An initial strategy uses high-accuracy satellite instruments, such as the NASA Moderate Resolution Imaging Spectroradiometer (MODIS) and Atmospheric Infrared Sounder (AIRS) and the European Organisation for the Exploitation of Meteorological Satellites (EUMETSAT)'s Centre National d'Études Spatiales (CNES) Infrared Atmospheric Sounding Interferometer (IASI), as space-based reference standards for intercalibrating the operational satellite sensors. Examples of initial intercalibration results and future plans are presented. Agencies participating in the program include the Centre National d'Études Spatiales, China Meteorological Administration, EUMETSAT, Japan Meteorological Agency, Korea Meteorological Administration, NASA, National Institute of Standards and Technology, and NOAA.
Radiative Climate Forcing by the Mount Pinatubo Eruption
Radiative flux anomalies derived from the National Aeronautics and Space Administration (NASA) spaceborne Earth Radiation Budget Experiment were used to determine the volcanic radiative forcing that followed the eruption of Mount Pinatubo in June 1991. They are the first unambiguous, direct measurements of large-scale volcanic forcing. The volcanic aerosols caused a strong cooling effect immediately; the amount of cooling increased through September 1991 as shortwave forcing increased relative to the longwave forcing. The primary effects of the aerosols were a direct increase in albedo over mostly clear areas and both direct and indirect increases in the albedo of cloudy areas.
Clouds and the Earth’s Radiant Energy System (CERES) FluxByCldTyp Edition 4 Data Product
The Clouds and the Earth’s Radiant Energy System (CERES) project has provided the climate community 20 years of globally observed top of the atmosphere (TOA) fluxes critical for climate and cloud feedback studies. The CERES Flux By Cloud Type (FBCT) product contains radiative fluxes by cloud type, which can provide more stringent constraints when validating models and also reveal more insight into the interactions between clouds and climate. The FBCT product provides 1° regional daily and monthly shortwave (SW) and longwave (LW) cloud-type fluxes and cloud properties sorted by seven pressure layers and six optical depth bins. Historically, cloud-type fluxes have been computed using radiative transfer models based on observed cloud properties. Instead of relying on radiative transfer models, the FBCT product utilizes Moderate Resolution Imaging Spectroradiometer (MODIS) radiances partitioned by cloud type within a CERES footprint to estimate the cloud-type broadband fluxes. The MODIS multichannel derived broadband fluxes were compared with the CERES observed footprint fluxes and were found to be within 1% and 2.5% for LW and SW, respectively, as well as being mostly free of cloud property dependencies. These biases are mitigated by constraining the cloud-type fluxes within each footprint with the CERES Single Scanner Footprint (SSF) observed flux. The FBCT all-sky and clear-sky monthly averaged fluxes were found to be consistent with the CERES SSF1deg product. Several examples of FBCT data are presented to highlight its utility for scientific applications.
ACHIEVING CLIMATE CHANGE ABSOLUTE ACCURACY IN ORBIT
The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5–50μm), the spectrum of solar radiation reflected by the Earth and its atmosphere (320–2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a “NIST [National Institute of Standards and Technology] in orbit.” CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.
A kernel-driven BRDF model to inform satellite-derived visible anvil cloud detection
Satellites routinely observe deep convective clouds across the world. The cirrus outflow from deep convection, commonly referred to as anvil cloud, has a ubiquitous appearance in visible and infrared (IR) wavelength imagery. Anvil clouds appear as broad areas of highly reflective and cold pixels relative to the darker and warmer clear sky background, often with embedded textured and colder pixels that indicate updrafts and gravity waves. These characteristics would suggest that creating automated anvil cloud detection products useful for weather forecasting and research should be straightforward, yet in practice such product development can be challenging. Some anvil detection methods have used reflectance or temperature thresholding, but anvil reflectance varies significantly throughout a day as a function of combined solar illumination and satellite viewing geometry, and anvil cloud top temperature varies as a function of convective equilibrium level and tropopause height. This paper highlights a technique for facilitating anvil cloud detection based on visible observations that relies on comparative analysis with expected cloud reflectance for a given set of angles, thereby addressing limitations of previous methods. A 1-year database of anvil-identified pixels, as determined from IR observations, from several geostationary satellites was used to construct a bidirectional reflectance distribution function (BRDF) model to quantify typical anvil reflectance across almost all expected viewing, solar, and azimuth angle configurations, in addition to the reflectance uncertainty for each angular bin. Application of the BRDF model for cloud optical depth retrieval in deep convection is described as well.
Angular Distribution Models for Top-of-Atmosphere Radiative Flux Estimation from the Clouds and the Earth’s Radiant Energy System Instrument on the Terra Satellite. Part II: Validation
Errors in top-of-atmosphere (TOA) radiative fluxes from the Clouds and the Earth’s Radiant Energy System (CERES) instrument due to uncertainties in radiance-to-flux conversion from CERES Terra angular distribution models (ADMs) are evaluated through a series of consistency tests. These tests show that the overall bias in regional monthly mean shortwave (SW) TOA flux is less than 0.2 W m−2 and the regional RMS error ranges from 0.70 to 1.4 W m−2. In contrast, SW TOA fluxes inferred using theoretical ADMs that assume clouds are plane parallel are overestimated by 3–4 W m−2 and exhibit a strong latitudinal dependence. In the longwave (LW), the bias error ranges from 0.2 to 0.4 W m−2 and regional RMS errors remain smaller than 0.7 W m−2. Global mean albedos derived from ADMs developed during the Earth Radiation Budget Experiment (ERBE) and applied to CERES measurements show a systematic increase with viewing zenith angle of 4%–8%, while albedos from the CERES Terra ADMs show a smaller increase of 1%–2%. The LW fluxes from the ERBE ADMs show a systematic decrease with viewing zenith angle of 2%–2.4%, whereas fluxes from the CERES Terra ADMs remain within 0.7%–0.8% at all angles. Based on several months of multiangle CERES along-track data, the SW TOA flux consistency between nadir- and oblique-viewing zenith angles is generally 5% (<17 W m−2) over land and ocean and 9% (26 W m−2) in polar regions, and LW TOA flux consistency is approximate 3% (7 W m−2) over all surfaces. Based on these results and a theoretically derived conversion between TOA flux consistency and TOA flux error, the best estimate of the error in CERES TOA flux due to the radiance-to-flux conversion is 3% (10 W m−2) in the SW and 1.8% (3–5 W m−2) in the LW. Monthly mean TOA fluxes based on ERBE ADMs are larger than monthly mean TOA fluxes based on CERES Terra ADMs by 1.8 and 1.3 W m−2 in the SW and LW, respectively.
Assessment of the Visible Channel Calibrations of the VIRS on TRMM and MODIS on Aqua and Terra
Several recent research satellites carry self-calibrating multispectral imagers that can be used for calibrating operational imagers lacking complete self-calibrating capabilities. In particular, the visible (VIS, 0.65 μm) channels on operational meteorological satellites are generally calibrated before launch, but require vicarious calibration techniques to monitor the gains and offsets once they are in orbit. To ensure that the self-calibrating instruments are performing as expected, this paper examines the consistencies between the VIS channel (channel 1) reflectances of the Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on the Terra and Aqua satellites and the version 5a and 6 reflectances of the Visible Infrared Scanner (VIRS) on the Tropical Rainfall Measuring Mission using a variety of techniques. These include comparisons of Terra and Aqua VIS radiances with coincident broadband shortwave radiances from the well-calibrated Clouds and the Earth’s Radiant Energy System (CERES), time series of deep convective cloud (DCC) albedos, and ray-matching intercalibrations between each of the three satellites. Time series of matched Terra and VIRS data, Aqua and VIRS data, and DCC reflected fluxes reveal that an older version (version 5a, ending in early 2004) of the VIRS calibration produced a highly stable record, while the latest version (version 6) appears to overestimate the sensor gain change by ∼1% yr−1 as the result of a manually induced gain adjustment. Comparisons with the CERES shortwave radiances unearthed a sudden change in the Terra MODIS calibration that caused a 1.17% decrease in the gain on 19 November 2003 that can be easily reversed. After correction for these manual adjustments, the trends in the VIRS and Terra channels are no greater than 0.1% yr−1. Although the results were more ambiguous, no statistically significant trends were found in the Aqua MODIS channel 1 gain. The Aqua radiances are 1% greater, on average, than their Terra counterparts, and after normalization are 4.6% greater than VIRS radiances, in agreement with theoretical calculations. The discrepancy between the two MODIS instruments should be taken into account to ensure consistency between parameters derived from them. With the adjustments, any of the three instruments can serve as references for calibrating other satellites. Monitoring of the calibrations continues in near–real time and the results are available via the World Wide Web.
Rapid Calibration of Operational and Research Meteorological Satellite Imagers. Part I: Evaluation of Research Satellite Visible Channels as References
Operational meteorological satellites generally lack reliable onboard calibration systems for solar-imaging channels. Current methods for calibrating these channels and for normalizing similar channels on contemporaneous satellite imagers typically rely on a poorly calibrated reference source. To establish a more reliable reference instrument for calibration normalization, this paper examines the use of research satellite imagers that maintain their solar-channel calibrations by using onboard diffuser systems that rely on the sun as an absolute reference. The Visible Infrared Scanner (VIRS) on the Tropical Rainfall Measuring Mission (TRMM) satellite and the second Along-Track Scanning Radiometer (ATSR-2) on the second European Remote Sensing Satellite (ERS-2) are correlated with matched data from the eighth Geostationary Operational Environmental Satellite (GOES-8), the fifth Geostationary Meteorological satellite (GMS-5), and with each other to examine trends in the solar channels. VIRS data are also correlated with the Terra satellite's Moderate Resolution Imaging Spectroradiometer (MODIS) provisional data as a preliminary assessment of their relative calibrations. As an additional check on their long-term stability, the VIRS data are compared to the relevant corresponding broadband shortwave radiances of the Clouds and the Earth's Radiant Energy System (CERES) scanners on TRMM. No statistically significant trend in the calibration of the VIRS 0.65- and 1.64-m channels could be detected from the comparisons with CERES data taken during 1998 and 2000. The VIRS-to-GOES-8 correlations revealed an annual degradation rate for the GOES-8 visible (0.67 m) channel of 7.5% and an initial drop of 16% in the gain from the prelaunch value. The slopes in the GOES-8 visible-channel gain trend lines derived from VIRS data taken after January 1998 and ATSR-2 data taken between October 1995 and December 1999 differed by only 1%-2% indicating that both reference instruments are highly stable. The mean difference of 3%;4.8% between the VIRS;GOES-8 and ATSR-2;GOES-8 gains is attributed to spectral differences between ATSR-2 and VIRS and to possible biases in the ATSR-2 channel-2 calibration. A degradation rate of 1.3% per year found for the GMS-5 visible channel was confirmed by comparisons with earlier calibrations. The MODIS and VIRS calibrations agreed to within 1% to 3%. Some of the differences between VIRS and the provisional MODIS radiances can be explained by spectral differences between the two instruments. The MODIS measures greater reflectance than VIRS for bright scenes. Although both VIRS and ATSR-2 provide temporally stable calibrations, it is recommended that, at least until MODIS calibrations are finalized, VIRS should be used as a reference source for normalizing operational meteorological satellite imagers because of its broader visible filter.
Temporal Interpolation Methods for the Clouds and the Earth’s Radiant Energy System (CERES) Experiment
The Clouds and the Earth’s Radiant Energy System (CERES) is a NASA multisatellite measurement program for monitoring the radiation environment of the earth–atmosphere system. The CERES instrument was flown on the Tropical Rainfall Measuring Mission satellite in late 1997, and will be flown on the Earth Observing System morning satellite in 1998 and afternoon satellite in 2000. To minimize temporal sampling errors associated with satellite measurements, two methods have been developed for temporally interpolating the CERES earth radiation budget measurements to compute averages of top-of-the-atmosphere shortwave and longwave flux. The first method is based on techniques developed from the Earth Radiation Budget Experiment (ERBE) and provides radiation data that are consistent with the ERBE processing. The second method is a newly developed technique for use in the CERES data processing. This technique incorporates high temporal resolution data from geostationary satellites to improve modeling of diurnal variations of radiation due to changing cloud conditions during the day. The performance of these two temporal interpolation methods is evaluated using a simulated dataset. Simulation studies show that the introduction of geostationary data into the temporal interpolation process significantly improves the accuracy of hourly and daily radiative products. Interpolation errors for instantaneous flux estimates are reduced by up to 68% for longwave flux and 80% for shortwave flux.