Ultrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trial
by
Heg, Dik
,
Roffi, Marco
,
Muller, Olivier
in
Absorbable Implants
,
Aged
,
Anti-Bacterial Agents - administration & dosage
2014
Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent.
We did a randomised, single-blind, non-inferiority trial with minimum exclusion criteria at nine hospitals in Switzerland. We randomly assigned (1:1) patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes undergoing percutaneous coronary intervention to treatment with biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Randomisation was via a central web-based system and stratified by centre and presence of ST segment elevation myocardial infarction. Patients and outcome assessors were masked to treatment allocation, but treating physicians were not. The primary endpoint, target lesion failure, was a composite of cardiac death, target vessel myocardial infarction, and clinically-indicated target lesion revascularisation at 12 months. A margin of 3·5% was defined for non-inferiority of the biodegradable polymer sirolimus-eluting stent compared with the durable polymer everolimus-eluting stent. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01443104.
Between Feb 24, 2012, and May 22, 2013, we randomly assigned 2119 patients with 3139 lesions to treatment with sirolimus-eluting stents (1063 patients, 1594 lesions) or everolimus-eluting stents (1056 patients, 1545 lesions). 407 (19%) patients presented with ST-segment elevation myocardial infarction. Target lesion failure with biodegradable polymer sirolimus-eluting stents (69 cases; 6·5%) was non-inferior to durable polymer everolimus-eluting stents (70 cases; 6·6%) at 12 months (absolute risk difference −0·14%, upper limit of one-sided 95% CI 1·97%, p for non-inferiority <0·0004). No significant differences were noted in rates of definite stent thrombosis (9 [0·9%] vs 4 [0·4%], rate ratio [RR] 2·26, 95% CI 0·70–7·33, p=0·16). In pre-specified stratified analyses of the primary endpoint, biodegradable polymer sirolimus-eluting stents were associated with improved outcome compared with durable polymer everolimus-eluting stents in the subgroup of patients with ST-segment elevation myocardial infarction (7 [3·3%] vs 17 [8·7%], RR 0·38, 95% CI 0·16–0·91, p=0·024, p for interaction=0·014).
In a patient population with minimum exclusion criteria and high adherence to dual antiplatelet therapy, biodegradable polymer sirolimus-eluting stents were non-inferior to durable polymer everolimus-eluting stents for the combined safety and efficacy outcome target lesion failure at 12 months. The noted benefit in the subgroup of patients with ST-segment elevation myocardial infarction needs further study.
Clinical Trials Unit, University of Bern, and Biotronik, Bülach, Switzerland.
Journal Article
Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial
by
Koolen, Jacques
,
Lüscher, Thomas F
,
Erbel, Raimund
in
Absorbable Implants
,
Angina pectoris
,
Angiography
2007
Coronary stents improve immediate and late results of balloon angioplasty by tacking up dissections and preventing wall recoil. These goals are achieved within weeks after angioplasty, but with current technology stents permanently remain in the artery, with many limitations including the need for long-term antiplatelet treatment to avoid thrombosis. We report a prospective multicentre clinical trial of coronary implantations of absorbable magnesium stents.
We enrolled 63 patients (44 men; mean age 61·3 [SD 9·5 years]) in eight centres with single de novo lesions in a native coronary artery in a multicentre, non-randomised prospective study. Follow-up included coronary angiography and intravascular ultrasound at 4 months and clinical assessment at 6 months and 12 months. The primary endpoint was cardiac death, non-fatal myocardial infarction, or clinically driven target lesion revascularisation at 4 months
71 stents, 10–15 mm in length and 3·0–3·5 mm in diameter, were successfully implanted after pre-dilatation in 63 patients. Diameter stenosis was reduced from 61·5 (SD 13·1%) to 12·6 (5·6%) with an acute gain of 1·41 mm (0·46 mm) and in-stent late loss of 1·08 mm (0·49 mm). The ischaemia-driven target lesion revascularisation rate was 23·8% after 4 months, and the overall target lesion revascularisation rate was 45% after 1 year. No myocardial infarction, subacute or late thrombosis, or death occurred. Angiography at 4 months showed an increased diameter stenosis of 48·4 (17·0%). After serial intravascular ultrasound examinations, only small remnants of the original struts were visible, well embedded into the intima. Neointimal growth and negative remodelling were the main operating mechanisms of restenosis.
This study shows that biodegradable magnesium stents can achieve an immediate angiographic result similar to the result of other metal stents and can be safely degraded after 4 months. Modifications of stent characteristics with prolonged degradation and drug elution are currently in development.
Journal Article
Decreased Rate of Coronary Restenosis after Lowering of Plasma Homocysteine Levels
by
Roffi, Marco
,
Hess, Otto M
,
Flammer, Yvonne
in
Angioplasty
,
Angioplasty, Balloon, Coronary
,
Biological and medical sciences
2001
In this double-blind study, a combination of folate, vitamin B
12
, and pyridoxine was found to reduce the rate of restenosis in patients who had undergone coronary angioplasty. There was less benefit in patients who had received stents than in those who had not. Vitamin therapy also resulted in lower plasma homocysteine levels, a potential mechanism of the clinical effect.
A relatively simple and inexpensive intervention reduced the risk of restenosis after coronary angioplasty.
The occurrence of restenosis after percutaneous coronary angioplasty remains an important limitation of the procedure,
1
and effective pharmacotherapy has been elusive.
2
–
5
Thus, the observation that the total plasma homocysteine level is an important predictor of cardiovascular risk
6
,
7
and correlates with the severity of coronary artery disease
8
,
9
has led to interest in its potential role in restenosis. Although the mechanism of homocysteine-induced vascular damage is not known, a number of potential links have been suggested.
10
–
14
We have previously shown that patients with plasma homocysteine levels below 9 μmol per liter have a 49 percent lower rate of . . .
Journal Article
Validity of Charlson Comorbidity Index in patients hospitalised with acute coronary syndrome. Insights from the nationwide AMIS Plus registry 2002–2012
by
Rickli, Hans
,
Bertel, Osmund
,
Puhan, Milo A
in
Acute Coronary Syndrome - epidemiology
,
Acute Coronary Syndrome - therapy
,
Acute coronary syndromes
2014
Objective This study aimed to assess the impact of individual comorbid conditions as well as the weight assignment, predictive properties and discriminating power of the Charlson Comorbidity Index (CCI) on outcome in patients with acute coronary syndrome (ACS). Methods A prospective multicentre observational study (AMIS Plus Registry) from 69 Swiss hospitals with 29 620 ACS patients enrolled from 2002 to 2012. The main outcome measures were in-hospital and 1-year follow-up mortality. Results Of the patients, 27% were female (age 72.1±12.6 years) and 73% were male (64.2±12.9 years). 46.8% had comorbidities and they were less likely to receive guideline-recommended drug therapy and reperfusion. Heart failure (adjusted OR 1.88; 95% CI 1.57 to 2.25), metastatic tumours (OR 2.25; 95% CI 1.60 to 3.19), renal diseases (OR 1.84; 95% CI 1.60 to 2.11) and diabetes (OR 1.35; 95% CI 1.19 to 1.54) were strong predictors of in-hospital mortality. In this population, CCI weighted the history of prior myocardial infarction higher (1 instead of −0.4, 95% CI −1.2 to 0.3 points) but heart failure (1 instead of 3.7, 95% CI 2.6 to 4.7) and renal disease (2 instead of 3.5, 95% CI 2.7 to 4.4) lower than the benchmark, where all comorbidities, age and gender were used as predictors. However, the model with CCI and age has an identical discrimination to this benchmark (areas under the receiver operating characteristic curves were both 0.76). Conclusions Comorbidities greatly influenced clinical presentation, therapies received and the outcome of patients admitted with ACS. Heart failure, diabetes, renal disease or metastatic tumours had a major impact on mortality. CCI seems to be an appropriate prognostic indicator for in-hospital and 1-year outcomes in ACS patients. ClinicalTrials.gov Identifier NCT01305785
Journal Article
Impact of total ischemic time on manual thrombus aspiration benefit during primary percutaneous coronary intervention
2018
The benefits of manual thrombus aspiration (TA) during primary percutaneous coronary intervention (pPCI) for ST-elevation myocardial infarction (STEMI) remain uncertain. We assessed the influence of total ischemic time (TIT) on clinical outcomes among STEMI patients undergoing manual TA during pPCI.
We conducted a retrospective study of patients enrolled in the Acute Myocardial Infarction in Switzerland Plus registry. STEMI patients undergoing pPCI with (TA group) or without (PCI-alone group) manual TA were stratified based on short (<3 hours), intermediate (3-6 hours), and long (>6 hours) TIT. The primary endpoint was in-hospital all-cause mortality. The secondary endpoint was in-hospital major adverse cardiac events (MACE), a composite of all-cause death, myocardial reinfarction and stroke.
Between 2008 and 2014, 4’154 patients (TA 48%) were included. Risk-adjusted in-hospital all-cause mortality was not different between TA and PCI-alone groups (OR 1.29; 95%CI 0.83-1.98; p=0.26), whereas there was significantly increased risk of MACE (OR 1.52; 95%CI 1.05-2.19; p=0.03) in patients treated with manual TA compared with PCI-alone. There was no significant difference between manual TA and PCI-alone with respect to risk-adjusted all-cause mortality according to TIT groups, but risk-adjusted MACE rates were significantly higher in the group of patients with long TIT treated with manual TA compared with PCI-alone (OR 2.42; 95%CI 1.16-5.04; p=0.02).
In a large registry of STEMI patients, manual TA was not associated with lower risk-adjusted in-hospital all-cause mortality compared with PCI-alone regardless of TIT but was associated with significantly greater risk of MACE. In patients with prolonged TIT, manual TA was associated with higher risk-adjusted MACE rates compared with PCI-alone.
Journal Article
Requirement of JNK2 for Scavenger Receptor A: Mediated Foam Cell Formation in Atherogenesis
2004
In vitro studies suggest a role for c-Jun N-terminal kinases (JNKs) in proatherogenic cellular processes. We show that atherosclerosis-prone ApoE-/-mice simultaneously lacking JNK2 ($ApoE^{-/-} JNK2^{-/-}$mice), but not ApoE-/-
$JNK1^{-/-}$mice, developed less atherosclerosis than do ApoE-/-mice. Pharmacological inhibition of JNK activity efficiently reduced plaque formation. Macrophages lacking JNK2 displayed suppressed foam cell formation caused by defective uptake and degradation of modified lipoproteins and showed increased amounts of the modified lipoprotein-binding and -internalizing scavenger receptor A (SR-A), whose phosphorylation was markedly decreased. Macrophage-restricted deletion of JNK2 was sufficient to decrease atherogenesis. Thus, JNK2-dependent phosphorylation of SR-A promotes uptake of lipids in macrophages, thereby regulating foam cell formation, a critical step in atherogenesis.
Journal Article
Clinical outcomes with thin versus thick strut polymer-free biolimus-coated stents at 3 years
by
Lipiecki, Janus
,
Sadozai Slama, Sara
,
Garot, Philippe
in
Aged
,
Angioplasty
,
Clinical outcomes
2024
BackgroundFor high bleeding-risk patients (HBR) undergoing percutaneous coronary intervention (PCI), the LEADERS FREE (LF) and LEADERS FREE II (LF II) trials established the safety and efficacy of a stainless steel polymer-free biolimus-coated stent (SS-BCS) with 30 days of dual antiplatelet treatment (DAPT). The LEADERS FREE III (LF III) trial investigated clinical outcomes after PCI with the next-generation cobalt-chromium thin-strut polymer-free biolimus-coated stent (CoCr-BCS) in HBR patients.AimsTo report the final 3-year results of the LF III trial and compare them to LF II.MethodsLF III was a prospective, multicentre, open-label single-arm study to evaluate the safety and efficacy of the CoCr-BCS stent. The primary safety endpoint was the composite of cardiac death (CD), myocardial infarction(MI) or definite/probable stent thrombosis (ST). The primary efficacy endpoint was clinically driven target lesion revascularisation (cd-TLR). We performed a propensity-matched comparison to the 3-year outcomes of LF II.ResultsAfter 3 years, CD/MI/ST had occurred in 57 patients (15%, 95% CI 11.8% to 19%) and cd-TLR in 23 (6.2%, 95% CI 4.1% to 9.2%) patients. In a propensity-matched comparison of patients treated with the CoCr-BCS versus the SS-BCS, there were similar rates of CD (6.6% vs 7.8%, p=0.50), MI (7.1% vs 8.3%, p=0.47) and definite/probable ST (1.1% vs 2%, HR 0.56, 95% CI 0.16 to 1.93, p=0.35). The rates of cd-TLR were 5.3% with CoCr-BCS versus 9.8% with SS-BCS (HR 0.54, 95% CI 0.31 to 0.96, p=0.03).ConclusionLF III confirms the long-term safety and efficacy of the CoCr-BCS in HBR patients treated with 1 month of DAPT.Trial registration numberNCT02843633, NCT03118895.
Journal Article
Ultrathin-strut, biodegradable-polymer, sirolimus-eluting stents versus thin-strut, durable-polymer, everolimus-eluting stents for percutaneous coronary revascularisation: 5-year outcomes of the BIOSCIENCE randomised trial
by
Heg, Dik
,
Roffi, Marco
,
Muller, Olivier
in
Absorbable Implants
,
Acute Coronary Syndrome - complications
,
Acute Coronary Syndrome - mortality
2018
Drug-eluting stents combining an ultrathin cobalt-chromium stent platform with a biodegradable polymer eluting sirolimus have been shown to be non-inferior or superior to thin-strut, durable-polymer, everolimus-eluting stents in terms of 1 year safety and efficacy outcomes.
In the randomised, single-blind, multicentre, non-inferiority BIOSCIENCE trial, we compared biodegradable-polymer sirolimus-eluting stents with durable-polymer everolimus-eluting stents in patients with chronic stable coronary artery disease or acute coronary syndromes. Here, we assess the final 5-year clinical outcomes of BIOSCIENCE with regards to the primary clinical outcome of target lesion failure, which was a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularisation. The primary analysis was done by intention to treat. The BIOSCIENCE trial is registered with ClinicalTrials.gov, number NCT01443104.
2008 (95%) of 2119 patients recruited between March 1, 2012, and May 31, 2013, completed 5 years of follow-up. Target lesion failure occurred in 198 patients (cumulative incidence 20·2%) treated with biodegradable-polymer sirolimus-eluting stents and in 189 patients (18·8%) treated with durable-polymer everolimus-eluting stents (rate ratio [RR] 1·07, 95% CI 0·88–1·31; p=0·487). All-cause mortality was significantly higher in patients treated with biodegradable-polymer sirolimus-eluting stents than in those treated with durable-polymer everolimus-eluting stents (14·1% vs 10·3%; RR 1·36, 95% CI 1·06–1·75; p=0·017), driven by a difference in non-cardiovascular deaths. We observed no difference between groups in cumulative incidence of definite stent thrombosis at 5 years (1·6% in both groups; 1·02, 0·51–2·05; p=0·950).
5-year risk of target lesion failure among all-comer patients undergoing percutaneous coronary intervention is similar after implantation of ultrathin-strut, biodegradable-polymer, sirolimus-eluting stents or thin-strut, durable-polymer, everolimus-eluting stents. Higher incidences of all-cause and non-cardiovascular mortality in patients treated with biodegradable-polymer stents eluting sirolimus than in those treated with durable-polymer stents eluting everolimus warrant careful observation in ongoing clinical trials.
Clinical Trials Unit of the University of Bern and Biotronik.
Journal Article
Improved outcomes of elderly patients treated with drug-eluting versus bare metal stents in large coronary arteries: Results from the BAsel Stent Kosten-Effektivitäts Trial PROspective Validation Examination randomized trial
2015
Drug-eluting stents (DES) improve outcomes in elderly patients with small coronary artery disease compared with bare-metal stents (BMS), but randomized data in elderly patients in need of large coronary stents are not available.
Planned secondary analysis of patients ≥75 years recruited to the “BASKET-PROVE” trial, in which 2,314 patients undergoing percutaneous coronary intervention for large (≥3.0 mm) native vessel disease were randomized 2:1 to DES (everolimus- vs sirolimus-eluting stents 1:1) versus BMS. All patients received 12 months of dual antiplatelet therapy. The primary end point was a composite of cardiac death or nonfatal myocardial infarction at 2 years.
Comparison of DES versus BMS among 405 patients ≥75 years showed significantly lower rates of the primary end point for DES (5.0% vs 11.6%; hazard ration (HR) 0.64 [0.44-0.91]; P = .014). Rates of nonfatal myocardial infarction (1.2% vs 5.5%, hazard ration (HR) 0.44 [0.21-0.83]; P = .009), all-cause death (7.4% vs 14.4%; HR 0.7 [0.51-0.95]; P = .02), and target vessel revascularization (TVR) (2.3% vs 6.2%; HR 0.59 [0.34-0.99]; P = .046) were also lower, whereas stent thrombosis and bleeding rates were similar. In contrast, among patients <75 years (n = 1,909), the only significant benefit of DES was a reduced rate of TVR (4.0% vs 8.7%, HR 0.66 [0.55-0.80]; P < .0001).
In patients ≥75 years requiring large (≥3.0 mm) coronary stents, use of DES was beneficial compared with BMS and reduced the rate of ischemic events, mortality, and TVR. These data suggest that DES should be preferred over BMS in elderly patients.
Journal Article
Efficacy and Safety of Abbreviated Eptifibatide Treatment in Patients With ST-Segment Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention
2021
•Eptifibatide mediates potent antithrombotic effects when used in primary PCI.•Standard eptifibatide infusion for several hours increases bleeding complications.•A novel, short eptifibatide regimen retains ischemic protection during primary PCI.•Bleeding complications are greatly reduced by the abbreviated eptifibatide regimen.•Avoiding prolonged eptifibatide treatment may improve clinical outcomes.
The glycoprotein IIb/IIIa inhibitor eptifibatide, administered as bolus followed by infusion, is an adjunctive antithrombotic treatment during primary percutaneous coronary intervention (PCI) in selected patients with ST-segment elevation myocardial infarction (STEMI). Whether both bolus and infusion are necessary to improve outcomes is unknown. We hypothesized that primary PCI with eptifibatide bolus only is non-inferior to the conventional treatment (bolus and infusion) with regard to infarct size, while reducing bleeding complications. We analyzed 720 consecutive STEMI patients receiving eptifibatide bolus only or conventional treatment in an observational case-control study utilizing propensity score matching of clinical and intervention-specific confounders. Infarct size was estimated based on myocardial bound creatine kinase, creatine kinase (CK), and CK area under the curve values, with a prespecified non-inferiority margin of 20%. Major bleeding was defined as type 2, 3, or 5 on the Bleeding Academic Research Consortium classification. Eptifibatide bolus only was administered to 147 patients (20%), which were matched 1:1 to patients receiving conventional treatment. Based on peak myocardial bound creatine kinase, CK and CK area under the curve values, infarct size was −8.4% (95% CI [−31.2%, 14.4%]), −11.6% (95% CI [−33.5%, 10.3%]), and −13.9% (95% CI [−34.1%, 6.2%]) after eptifibatide bolus, respectively, reaching prespecified noninferiority compared with conventional treatment. Bolus treatment significantly reduced major bleeding complications (OR 0.48, 95% CI [0.30, 0.79]). In conclusion, eptifibatide given as abbreviated bolus only to selected STEMI patients who underwent primary PCI was noninferior regarding infarct size and resulted in less bleeding complications compared with conventional bolus and infusion treatment.
Journal Article