Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
4
result(s) for
"Eichhorn, Anna L."
Sort by:
Torsional and lateral eigenmode oscillations for atomic resolution imaging of HOPG in air under ambient conditions
2022
Combined in-plane and out-of-plane multifrequency atomic force microscopy techniques have been demonstrated to be important tools to decipher spatial differences of sample surfaces at the atomic scale. The analysis of physical properties perpendicular to the sample surface is routinely achieved from flexural cantilever oscillations, whereas the interpretation of in-plane sample properties via force microscopy is still challenging. Besides the torsional oscillation, there is the additional option to exploit the lateral oscillation of the cantilever for in-plane surface analysis. In this study, we used different multifrequency force microscopy approaches to attain better understanding of the interactions between a super-sharp tip and an HOPG surface focusing on the discrimination between friction and shear forces. We found that the lateral eigenmode is suitable for the determination of the shear modulus whereas the torsional eigenmode provides information on local friction forces between tip and sample. Based on the results, we propose that the full set of elastic constants of graphite can be determined from combined in-plane and out-of-plane multifrequency atomic force microscopy if ultrasmall amplitudes and high force constants are used.
Journal Article
Adsorbate Formation/Removal and Plasma‐Induced Evolution of Defects in Graphitic Materials
2023
The preparation of adsorbate‐free graphene with well‐defined layer numbers is a current challenge in materials and surface science and required to fabricate graphene‐based nanodevices, such as used in nanoelectromechanical systems. One strategy to tailor the layer number is oxygen‐plasma treatment of few‐layer graphene/graphite flakes. However, when graphitic materials are stored in air under ambient conditions, it is almost inevitable that adsorbates deposit on their surfaces. When precisely removing individual graphene layers from graphitic flakes by oxygen‐plasma treatment, the amount and type of adsorbates strongly affect the required plasma‐treatment process and duration. To examine the removal/etching mechanism involved in removing such layers, few‐layer graphene/graphite flakes, with areas of different layer numbers, are stored in ambient air and stepwise exposed to oxygen plasma in a shielded configuration. The flakes are then successively analyzed by multifrequency atomic force microscopy together with Raman spectroscopy, focusing on etching rate, and adsorbate and defect evolution. Combined in‐plane and out‐of‐plane tip–adsorbate–substrate interaction analysis facilitates discrimination of different types of adsorbates (water, polycyclic aromatic hydrocarbons, and linear alkanes) and their formation with time. The results demonstrate the potential regarding the development of an efficient method for cleaning of graphitic surfaces and ablation of individual graphene layers. The preparation of adsorbate‐free graphene with well‐defined layer numbers is a current challenge in materials science. By stepwise storage and plasma treatment of few‐layer graphene/graphite flakes analyzed by multifrequency atomic force microscopy together with Raman spectroscopy, this study demonstrates the potential regarding the development of an efficient method for cleaning of graphitic surfaces and ablation of individual graphene layers.
Journal Article
Feasibility Study on Cardiac Arrhythmia Ablation Using High-Energy Heavy Ion Beams
by
Constantinescu, Anna
,
Takami, Mitsuru
,
Helmbrecht, Stephan
in
59/78
,
639/766/419/1131
,
692/4019
2016
High-energy ion beams are successfully used in cancer therapy and precisely deliver high doses of ionizing radiation to small deep-seated target volumes. A similar noninvasive treatment modality for cardiac arrhythmias was tested here. This study used high-energy carbon ions for ablation of cardiac tissue in pigs. Doses of 25, 40, and 55 Gy were applied in forced-breath-hold to the atrioventricular junction, left atrial pulmonary vein junction, and freewall left ventricle of intact animals. Procedural success was tracked by (1.) in-beam positron-emission tomography (PET) imaging; (2.) intracardiac voltage mapping with visible lesion on ultrasound; (3.) lesion outcomes in pathohistolgy. High doses (40–55 Gy) caused slowing and interruption of cardiac impulse propagation. Target fibrosis was the main mediator of the ablation effect. In irradiated tissue, apoptosis was present after 3, but not 6 months. Our study shows feasibility to use high-energy ion beams for creation of cardiac lesions that chronically interrupt cardiac conduction.
Journal Article
A pilot study of evaluation of semi-rigid and flexible catheters for less invasive surfactant administration in preterm infants with respiratory distress syndrome—a randomized controlled trial
by
Hofstätter, Edda
,
Brandner, Johannes
,
Schütz, Sebastian
in
Birth weight
,
Care and treatment
,
Caregivers
2022
Background
In respiratory distress syndrome, many neonatology centers worldwide perform minimal invasive surfactant application in premature infants, using small-diameter catheters for endotracheal intubation and surfactant administration.
Methods
In this single-center, open-label, randomized-controlled trial, preterm infants requiring surfactant administration after birth, using a standardized minimal invasive protocol, were randomized to two different modes of endotracheal catheterization: Flexible charrière-4 feeding tube inserted using Magill forceps (group 1) and semi-rigid catheter (group 2). Primary outcome was duration of laryngoscopy. Secondary outcomes were complication rate (intraventricular hemorrhage, soft-tissue damage in first week of life) and vital parameters during laryngoscopy. Between 2019 and 2020, 31 infants were included in the study. Prior to in-vivo testing, laryngoscopy durations were studied on a neonatal airway mannequin in students, nurses and doctors.
Results
Mean gestational age and birth weight were 27 + 6/7 weeks and 1009 g; and 28 + 0/7 weeks and 1127 g for group 1 and 2, respectively. Length of laryngoscopy was similar in both groups (61.1 s and 64.9 s) overall (p.77) and adjusted for weight (p.70) or gestational age (p.95). Laryngoscopy failed seven times in group 1 (43.8%) and four times (26.7%) in group 2 (p.46). Longer laryngoscopy was associated with lower oxygen saturation with lowest levels occurring after failed laryngoscopy attempts. Secondary outcomes were similar in both groups. In vitro data on 40 students, 40 nurses and 12 neonatologists showed significant faster laryngoscopy in students and nurses group 2 (
p
< .0001) unlike in neonatologists (p.13).
Conclusion
This study showed no difference in laryngoscopy duration in endotracheal catheterization when comparing semi-rigid and flexible catheters for minimal invasive surfactant application in preterm infants. In accordance with preliminary data and in contrast to published in-vitro trials, experienced neonatologists were able to perform endotracheal catheterization using both semi-rigid and flexible catheters at similar rates and ease, in vitro and in vivo.
Trial registration
ClinicalTrials.gov.
NCT05024435
Registered 27 August 2021—Retrospectively registered.
Journal Article