Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
51 result(s) for "Eickhoff, Alexander"
Sort by:
Feasibility and Radiological Outcome of Minimally Invasive Locked Plating of Proximal Humeral Fractures in Geriatric Patients
Background: Proximal humerus fractures are common injuries in the elderly. Locked plating showed high complication and reoperation rates at first. However, with second-generation implants and augmentation, minimally invasive locked plating might be a viable alternative to arthroplasty or conservative treatment. Material and Methods: A retrospective chart review was performed for all patients with proximal humerus fractures treated between 2014 and 2020 with locked plating. All patients over 60 years of age who underwent surgery for a proximal humerus fracture with plate osteosynthesis (NCB, Philos, or Philos with cement) during the specified period were included. Pathological fractures, intramedullary nailing, or arthroplasty were excluded. Primary outcome measurements included secondary displacement and surgical complications. Secondary outcomes comprised function and mortality within one year. Results: A total of 249 patients (mean age 75.6 +/− 8.9 years; 194 women and 55 men) were included in the study. No significant difference in the AO fracture classification could be found. Ninety-two patients were surgically treated with first-generation locked plating (NCB, Zimmer Biomet, Wayne Township, IN, USA), 113 patients with second-generation locked plating (Philos, Depuy Synthes, Wayne Township, IN, USA), and 44 patients with cement-augmented second-generation locked plating (Philos, Traumacem V+, Depuy Synthes). A 6-week radiological follow-up was completed for 189 patients. In all groups, X-rays were performed one day after surgery, and these showed no differences concerning the head shaft angle between the groups. The mean secondary varus dislocation (decrease of the head shaft angle) after six weeks for first-generation locked plating was 6.6 ± 12° (n = 72), for second-generation locked plating 4.4 ± 6.5 (n = 83), and for second-generation with augmentation 1.9 ± 3.7 (n = 35) with a significant difference between the groups (p = 0.012). Logistic regression showed a significant dependency for secondary dislocation for the type of treatment (p = 0.038), age (p = 0.01), and preoperative varus fracture displacement (p = 0.033). Significantly fewer surgical complications have been observed in the augmented second-generation locked plating group (NCB: 26.3%; Philos 21.5%; Philos-augmented 8.6%; p = 0.015). Range of motion was documented in 122 out of 209 patients after 3 months. In the Philos-augmented group, 50% of the patients achieved at least 90° anteversion and abduction, which was only about a third of the patients in the other 2 groups (NCB 34.8%, n = 46; Philos 35.8%, n = 56; augmented-Philos 50.0%, n = 20; p = 0.429). Conclusion: Minimally invasive locked plating is still a valuable treatment option for geriatric patients. With augmentation and modern implants, the complication rate is low and comparable to those of reverse shoulder arthroplasty reported in the literature, even in the challenging group of elderly patients.
Mortality After Iliosacral Screw Fixation for Osteoporotic Pelvic Ring Fractures
Background Fragility fractures of the posterior pelvic ring are associated with osteoporosis and are becoming more common with demographic change. Known limitations of conservative therapy include a significant loss of autonomy and high mortality. Surgical stabilisation using percutaneous sacroiliac (SI) or trans-iliac trans-sacral (TITS) screws, has been established to increase mobility, but long-term results have not yet been studied. Materials and Methods 138 patients with percutaneous SI and TITS screw fixation of the posterior pelvic ring in osteoporotic fragility fractures were followed up for more than a year postoperatively in this retrospective study. Thereby, all patients were operated in the conventional supine position in a hybrid operating room consisting of a fixed, robot-assisted 3D flat-panel detector and a navigation system. Results 34 patients were male and 104 female. The mean age was 77.6 ± 9 years. 26 patients were ASA 1 + 2, 93 patients ASA 3 and 19 patients ASA 4. 80 fractures were classified as FFP 2, 23 FFP 3 and 35 FFP 4. Time to surgery was 127.5 ± 113.2 hours. Hospitalisation lasted an average of 15.7 ± 8.5 days. At the time of discharge, 68.8% of the patients had regained their original mobility, while 31.2% remained limited. The home situation remained unchanged in 73.9% of the patients, worsened in 26.1% and improved in 2.8%. 90.6% of the screw fixations showed no signs of loosening. In 9.4%, loosening could not be ruled out radiologically, but a surgical revision was not necessary. The 1-year mortality rate was 10.1%. Conclusion Percutaneous navigated screw fixation of the posterior pelvic ring in fragility fractures is a simple, safe, minimally invasive and precise method with good clinical results in terms of rapid recovery with early mobilization of patients to maintain autonomy and reduce mortality. Further clinical studies with controlled cohorts and a large number of patients with long follow-up periods should be carried out to compare the procedure with other methods. In particular, the question of an additional standardized treatment of the anterior pelvic ring in unstable dislocated fragility fractures should be investigated.
Is new always better: comparison of the femoral neck system and the dynamic hip screw in the treatment of femoral neck fractures
BackgroundHip fractures in the elderly population are common and the number of patients is rising. For young and geriatric patients with undisplaced fractures osteosynthesis is the primary type of treatment. The dynamic hip screw (DHS) is around for many years and proved its value especially in displaced fractures. Since 2018 the femoral neck system (FNS) is available as an alternative showing promising biomechanical results. The aim of this study is to evaluate clinical results of the FNS and compare it to the DHS.Materials and methodsPatients older than 18 years with Garden I–IV fractures that were treated with osteosynthesis in a level 1 trauma center were included in the study. Between January 2015 and March 2021, all patients treated with FNS (1-hole plate, DePuy-Synthes, Zuchwil, Switzerland) or DHS (2-hole plate, DePuy-Synthes, Zuchwil, Switzerland) for proximal femur fractures were included in the study. Closed reduction was achieved using a traction table. All operations were carried out by experienced orthopedic trauma surgeons. Primary outcome measures were rate of implant failure (cut out) and surgical complications (hematoma, infection). Secondary outcome measures were Hb-difference, length of hospital stay and mortality.ResultsOverall, 221 patients were included in the study. 113 were treated with FNS, 108 with DHS. Mean age was 69 ± 14 years. There were 17.2% Garden I, 47.5% Garden II, 26.7% Garden III and 8.6% Garden IV fractures. No difference between the groups for age, body mass index (BMI), Charlson comorbidity index (CCI), time to surgery, Pauwels and Garden classification, rate of optimal blade position or tip apex distance was found. FNS showed lower pre- to postoperative Hb-difference (1.4 ± 1.1 g/l vs. 2.1 ± 1.4 g/l; p < 0.05), shorter operating time (36.3 ± 11.6 min vs. 54.7 ± 17.4 min; p < 0.05) and hospital stay (8.8 ± 4.3 d vs. 11.2 ± 6.8 d; p < 0.05). Surgical complications (FNS 13.3% vs. DHS 18.4%, p > 0.05), rate of cut out (FNS 12.4% vs. DHS 10.2%, p > 0.05) and mortality (FNS 3.5%; DHS 0.9%; p > 0.05) showed no difference between the groups. Logistic regression showed that poor blade position was the only significant predictor for cut out and increased the risk by factor 7. Implant related infection (n = 3) and hematoma/seroma (n = 6) that needed revision was only seen in DHS group.ConclusionFNS proved to be as reliable as DHS in all patients with hip fractures. Not the type of implant but blade positioning is still key to prevent implant failure. Still due to minimal invasive approach implant related infections and postoperative hematomas might have been prevented using the FNS.
Intraoperative 3D imaging in plate osteosynthesis of proximal humerus fractures
IntroductionProximal humerus fractures are common and often associated with osteoporosis in the elderly. Unfortunately, the complication and revision rate for joint-preserving surgical treatment using locking plate osteosynthesis is still high. Problems include insufficient fracture reduction and implant misplacement. Using conventional intraoperative two dimensional (2D) X-ray imaging control in only two planes, a completely error-free assessment is not possible.Materials and methodsThe feasibility of intraoperative three-dimensional (3D) imaging control for locking plate osteosynthesis with screw tip cement augmentation of proximal humerus fractures was retrospectively studied in 14 cases with an isocentric mobile C-arm image intensifier set up parasagittal to the patients.ResultsThe intraoperative digital volume tomography (DVT) scans were feasible in all cases and showed excellent image quality. One patient showed inadequate fracture reduction in the imaging control, which then could be corrected. In another patient, a protruding head screw was detected, which could be replaced before augmentation. Cement distribution in the humeral head was consistent around the screw tips with no leakage into the joint.ConclusionThis study shows that insufficient fracture reduction and implant misplacement can be easily and reliably detected by intraoperative DVT scan with an isocentric mobile C-arm set up in the usual parasagittal position to the patient.
Epidemiology, patterns, and mechanisms of pediatric trauma: a review of 12,508 patients
BackgroundPediatric traumas are common and remain a unique challenge for trauma surgeons. Demographic data provide a crucial source of information to better understand mechanisms and patterns of injury. The aim of this study was to provide this information to improve treatment strategies of potentially preventable morbidity and mortality in children.Material and methodsA retrospective review of every pediatric trauma treated in the emergency department (ED) between 2015 and 2019 was performed. Inclusion criteria were the age between 0 and 14 years and admission to the ED after trauma. Demographic data, time of presentation, mechanism of injury and pattern of injury, treatment, and outcome were analyzed. Different injury patterns were assessed in relation to age group, sex, mechanism of injury and treatment.ResultsA total of 12,508 patients were included in this study. All patients were stratified into five age groups: babies under the age of 1 (8.8%), toddlers between 1 and 3 (16.8%), preschool children between 4 and 6 (19.3%), young school children between 7 and 10 (27.1%), and young adolescents between 11 and 14 (27.9%). The predominant sex in all age groups was male. 47.7% of patients were admitted between 4 and 10 pm; 14.8% of the patients arrived between 10 pm and 8 am. Peak months of admissions were May to July. Overall, 2703 fractures, 2924 lacerations and superficial tissue injury, 5151 bruises, 320 joint dislocations, 1284 distortions, 76 burns, and 50 other injuries were treated. Most common mechanisms for fractures were leisure activities, falls, and sports-related activities. Forearm fractures were the most common fractures (39.5%) followed by humerus fractures (14%) and fractures of the hand (12.5%). A total of 700 patients with fractures (25.9%) needed surgery. 8.8% of all patients were hospitalized for at least one day. 4 patients died in the hospital (0.03%).ConclusionDespite of higher risk, severe injuries in children are rare. Minor injuries and single fractures are common. Treatment should be managed in specialized centers to ensure an interdisciplinary care and fast recovery. Peak times in the late afternoon and evening and summer months should be taken into consideration of personnel planning.
3D C-arm navigated acromioclavicular joint stabilization
Introduction Surgical treatment options for acromioclavicular joint separations are varied. Frequently, suspension devices (SD) are inserted for stabilization under arthroscopic view. This study investigates the feasibility and accuracy of three-dimensional (3D) digital-volume-tomography (DVT) C-arm navigated implantation with regard to the general trend toward increasingly minimally invasive procedures. Materials and methods The implantation of a TightRope ® suture button system (SD) via a navigated vertical drill channel through the clavicle and coracoid was investigated in 10 synthetic shoulder models with a mobile isocentric C-arm image intensifier setup in the usual parasagittal position. Thereby, in addition the placement of an additive horizontal suture cerclage via a navigated drill channel through the acromion was assessed. Results All vertical drill channels in the Coracoclavicular (CC) direction could be placed in a line centrally through the clavicle and the coracoid base. The horizontal drill channels in the Acromioclavicular (AC) direction ran strictly in the acromion, without affecting the AC joint or lateral clavicle. All SD could be well inserted and anchored. After tensioning and knotting of the system, the application of the horizontal AC cerclage was easily possible. The image quality was good and all relevant structures could be assessed well. Conclusion Intraoperative 3D DVT imaging of the shoulder joint using a mobile isocentric C-arm in the usual parasagittal position to the patient is possible. Likewise, DVT navigated SD implantation at the AC joint in CC and AC direction on a synthetic shoulder model. By combining both methods, the application in vivo could be possible. Further clinical studies on feasibility and comparison with established methods should be performed.
Short-term outcome of fragility fractures of the pelvis in the elderly treated with screw osteosynthesis and external fixator
BackgroundThe treatment of fragility fractures of the pelvis is rising challenge for orthopedic trauma surgeons. Operative treatment should allow immediate full weight bearing and early mobilisation but should also be as minimal invasive as possible. Sacroiliac (SI) or transsacral transiliac screws (TSTI) alone or depending on the fracture in combination with an external fixator meets both of these criteria.Material and methodsThe outcome of 121 operatively treated patients with fragility fractures of the pelvis were evaluated in this retrospective study. Depending on the type of fracture the patients were treated with navigated SI screw or TSTI screw alone or in combination with an external fixator. All patients were operated in supine position in a hybrid-OR, which consists of a fixed robotic 3D flatpanel detector (Artis zeego, Siemens Healthineers, Germany) and a navigation system (BrainLab Curve, BrainLab, Germany).Results37 patients were treated with either one or two SI screws and 57 with one TSTI screw. An additional external fixator was combined with SI screws in 17 patients and with TSTI screws in 10 patients. The preoperative pain score was significantly higher compared to the postoperative score (5.1 ± 2.5 vs 2.2 ± 1.9, p < 0.05). Follow-up at 6 month was possible for 106 patients which showed screw loosening in 16.3% of the SI Screws (n = 49) compared to only 5.2% of TSTI screws (n = 57). No screw loosening was seen in the combination of TSTI-screw and external fixator (n = 10). There were two septic and three aseptic pin loosenings of the external fixator. Overall only one patient needed revision surgery due to screw loosening and local irritation. Overall 75.2% (n = 91) of the patients could be released in their home or in a rehabilitation unit and only 14% (n = 17) were released to a nursing home due to immobility despite the operation. Non-surgical complications rate was 21.5%.ConclusionSI or TSTI screws with possible combination with an external fixator show early pain relief and allows most of the patients to keep their former level of independence. With an also low surgical complication rate, it proved to be a safe and reliable treatment for fragility fractures of the pelvis. Due the effective pain relief and the minimal invasive approach, early mobilisation is possible and might prevent typical non-surgical complications which are very common during conservative treatment.
Clinical performance of the Femoral Neck System within 1 year in 125 patients with acute femoral neck fractures, a prospective observational case series
IntroductionOsteosynthesis of femoral neck fractures (FNFs) is an important treatment option, especially for younger patients. We aimed to assess the rate of early implant-related complications in FNF osteosynthesis using the Femoral Neck System (FNS).Patients and methodsConsecutive patients diagnosed with displaced or nondisplaced FNFs were treated with FNS in this prospective, observational, multicenter investigation. Patients were followed up for minimally 3 months and up to 12 months if radiologic bone union and no pain was not achieved beforehand. Predefined treatment-related adverse events (AEs, defined as implant failure, loss of reduction, iatrogenic fractures, deep infection, and surgical revision), radiologic bone union, and patient-reported Harris hip score (HHS) and EQ-5D-5L index score were assessed.ResultsOne hundred and twenty-five patients were included in the study. Thirty-eight (30.4%) fractures were displaced (Garden III and IV), and 37 (29.6%) were vertical fractures (Pauwels type III). Predefined treatment-related AE rate at 3 months was 8 patients, 6.4% (95% CI, 2.8–12.2), and at 12 months, 11 patients, 8.8% (95% CI, 4.5–15.2). Cumulative incidences of bone union were 68% at 3 months, 90% at 6 months, and 98% at 12 months. The mean changes of HHS and EQ-5D-5L index score between preinjury and at 12 months were -7.5 (95% CI, [ – 21.1] to [6.2]) and  – 0.03 (95% CI, [ – 0.21] to [0.15]), respectively; neither were statistically significant.ConclusionThe current study on osteosynthesis of FNFs with the FNS resulted in treatment-related complication rates of 6.4% (95% CI, 2.8–12.2) at 3 months and 8.8% (95% CI, 4.5–15.2) at 12 months. On average, patients returned to preinjury function and quality of life. The current study may also indicate that the conventional wisdom of treating stable FNF in patients aged between 60 and 80 years with osteosynthesis may need to be reconsidered.RegistrationThe study is registered with ClinicalTrials.gov (registration number: NCT02422355).
Analysis of partial weight bearing after surgical treatment in patients with injuries of the lower extremity
IntroductionAfter surgical treatment of injuries of the lower extremity, partial weight bearing is often suggested until soft tissue consolidation. It is doubtful, if this recommendation can be implemented, even in the case that a patient is performing partial weight bearing with a physical therapist. Consequently the question remains, if patients are able to implement partial weight bearing after surgery and which factors favor incompliance.Materials and methods49 patients, who underwent surgical treatment after injuries of the lower extremity, were equipped with electronic shoe insoles on both sides. Different weight bearing instructions were given depending on the type of injury and surgery (full weight bearing vs. 20 kg weight bearing vs. non-weight bearing). Besides loading, other factors like age, gender, weight and physical activity were evaluated. Statistical analysis was performed using Chi-square and Fisher’s exact test with significance set at a p value < 0.05.Results25 of the 40 patients, who had to perform non- or partial weight bearing, were not able to follow postoperative instructions (compliance rate 37.5%). The average loading of the whole collective was 32.6 kg (4.8–109.2 kg). The specification of loading had no statistically significant influence on real loading (p-value 0.39). Elderly patients were less able to follow instructions than younger patients (36 vs 30.2 kg). Physically active compared to non-active patients overloaded their injured extremity (37.8 vs 28.7 kg). Patients with a high body mass index (BMI) encountered more difficulties to perform partial weight bearing than lightweight patients (36.9 vs 25.1 kg).ConclusionsMost patients were not able to follow loading limitation, even a few days after surgery and even if the patients were trained by a physiotherapist. Excessive weight bearing-related complications should be evaluated.
3D C-arm navigated suture button implantation for AC joint dislocations - the pilot study
   Purpose The surgical treatment of acute traumatic AC joint dislocations is still a subject of scientific debate in the literature. The arthroscopically assisted stabilization procedure with a suture button system has been successfully established and is widely used in daily practice. It is minimally invasive and allows the anatomical reconstruction of the torn coracoclavicular ligaments in one step with a permanent implant that does not have to be removed in a second operation. This clinical pilot study is the first to describe the new method of navigated suture button implantation with the future aim of further reducing surgical invasiveness and further increasing surgical precision. Materials and methods 10 patients with a Rockwood 3b/5 injury could be included in the prospective study (DRKS00031855) within 5 months according to inclusion and exclusion criteria. Surgical stabilization was performed with a suture button system via a navigated coracoclavicular drill tunnel. Demographic and radiological data as well as information on health and shoulder function were collected from patient records, X-rays, DVT scan and 3 questionnaires (DASH, NHS and Eq. 5D) at the preoperative, intraoperative and postoperative (discharge, 6 weeks and 3 months) time points. Results All operations could be performed within 8.8 days (± 6.81) after trauma. The average operation time was 50.3 min (± 8.81). The mean distance of the drill hole in the clavicle to the AC joint was 26.6 mm (± 2.63). The radiologically measured vertical coracoclavicular distance was 38.8 mm (± 6.16) at discharge and 41.11 mm (± 7.51) at 3 months. This loss of reduction was not statistically significant. In contrast, the DASH, NHS and Eq. 5D results showed significant improvement from discharge to 3 months postoperatively. Conclusion Image-guided 3D C-arm navigated AC joint suture button stabilization is feasible in everyday surgical practice. It may be possible to achieve a further reduction in invasiveness while at the same time increasing the accuracy of implant positioning. Further clinical studies with a larger number of patients and a longer follow-up period are necessary to enable a comparison with conventional methods.