Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
2 result(s) for "El-Gowily, Ahmed G."
Sort by:
Methodology for analysis and reporting patterns of failure in the Era of IMRT: head and neck cancer applications
Background The aim of this study is to develop a methodology to standardize the analysis and reporting of the patterns of loco-regional failure after IMRT of head and neck cancer. Material and Methods Twenty-one patients with evidence of local and/or regional failure following IMRT for head-and-neck cancer were retrospectively reviewed under approved IRB protocol. Manually delineated recurrent gross disease (rGTV) on the diagnostic CT documenting recurrence (rCT) was co-registered with the original planning CT (pCT) using both deformable (DIR) and rigid (RIR) image registration software. Subsequently, mapped rGTVs were compared relative to original planning target volumes (TVs) and dose using a centroid-based approaches. Failures were then classified into five types based on combined spatial and dosimetric criteria; A (central high dose), B (peripheral high dose), C (central elective dose), D (peripheral elective dose), and E (extraneous dose). Results A total of 26 recurrences were identified. Using DIR, recurrences were assigned to more central TVs compared to RIR as detected using the spatial centroid-based method ( p  = 0.0002). rGTVs mapped using DIR had statistically significant higher mean doses when compared to rGTVs mapped rigidly (mean dose 70 vs. 69 Gy, p  = 0.03). According to the proposed classification 22 out of 26 failures were of type A (central high dose) as assessed by DIR method compared to 18 out of 26 for the RIR because of the tendencey of RIR to assign failures more peripherally. Conclusions RIR tends to assigns failures more peripherally. DIR-based methods showed that the vast majority of failures originated in the high dose target volumes and received full prescribed doses suggesting biological rather than technology-related causes of failure. Validated DIR-based registration is recommended for accurate failure characterization and a novel typology-indicative taxonomy is recommended for failure reporting in the IMRT era.
Patterns of locoregional failure following post-operative intensity-modulated radiotherapy to oral cavity cancer: quantitative spatial and dosimetric analysis using a deformable image registration workflow
Background We sought to identify spatial/dosimetric patterns of failure for oral cavity cancer patients receiving post-operative IMRT (PO-IMRT). Methods Two hundred eighty-nine OCC patients receiving PO-IMRT were retrospectively reviewed from 2000 to 2012. Diagnostic CT documenting recurrence (rCT) was co-registered with planning CT (pCT) using a validated deformable image registration software. Manually segmented recurrent gross disease (rGTV) was deformed to co-registered pCTs. Mapped rGTVs were compared dosimetrically to planned dose and spatially to planning target volumes using centroid-based approaches. Failures types were classified using combined spatial/dosimetric criteria: A (central high-dose), B (peripheral high-dose), C (central intermediate/low-dose), D (peripheral intermediate/low-dose), and E (extraneous-dose). Results Fifty-four patients with recurrence were analyzed; 26 local recurrence, 19 regional recurrence, and 9 both local and regional recurrence. Median time to recurrence was 4 months (range 0–71). Median rGTVs volume was 3.7 cm 3 (IQR 1.4–10.6). For spatial and dosimetric analysis of the patterns of failure, 30 patients (55.5%) were classified as type A (central high-dose). Non-central high dose failures were distributed as follows: 2 (3.7%) type B, 10 (18.5%) type C, 1 (1.8%) type D, and 9 (16.7%) type E. Non-IMRT failure in the matching low-neck field was seen in two patients. No failures were noted at the IMRT-supraclavicular field match-line. Conclusions Approximately half of patients with local/regional failure had non-central high dose recurrence. Peripheral high dose misses were uncommon reflecting adequate delineation and dose delivery. Future strategies are needed to reduce types C and E failures.