Fixation techniques and stem dimensions in hinged total knee arthroplasty: a finite element study
2016
IntroductionNo evidence-based guidelines are available to determine the appropriate stem length, and whether or not to cement stems in revision total knee arthroplasty (TKA). Therefore, the objective of this study was to compare stresses and relative movement of cemented and uncemented stems of different lengths using a finite element analysis.Materials and methodsA finite element model was created for a synthetic tibia. Two stem lengths (95 and 160 mm) and two types of fixation (cemented or press fit) of a hinged TKA were examined. The average compressive stress distribution in different regions of interest, as well as implant micromotions, was determined and compared during lunge and squat motor tasks.ResultsBoth long and short stems in revision TKA lead to high stresses, primarily in the region around the stem tip. The presence of cement reduces the stresses in the bone in every region along the stem. Short stem configurations are less affected by the presence of cement than the long stem configuration. Press-fit stems showed higher micromotions compared to cemented stems.ConclusionsLowest stresses and micromotion were found for long cemented stems. Cementless stems showed more micromotion and increased stress levels especially at the level of the stem tip, which may explain the clinical phenomenon of stem-end pain following revision knee arthroplasty. These findings will help the surgeon with optimal individual implant choice.
Journal Article
Concomitant glenohumeral pathologies in high-grade acromioclavicular separation (type III – V)
by
Malcherczyk, Dominik
,
Markel, Jochen
,
Ruchholtz, Steffen
in
Acromio-clavicular joint separation
,
Acromioclavicular joint
,
Articular cartilage
2017
Background
Acromioclavicular joint (ACJ) dislocations are common injuries of the shoulder associated with physical activity. The diagnosis of concomitant injuries proves complicated due to the prominent clinical symptoms of acute ACJ dislocation. Because of increasing use of minimally invasive surgery techniques concomitant pathologies are diagnosed more often than with previous procedures.
Methods
The aim of this study was to identify the incidence of concomitant intraarticular injuries in patients with high-grade acromioclavicular separation (Rockwood type III – V) as well as to reveal potential risk constellations. The concomitant pathologies were compiled during routine arthroscopically assisted treatment in altogether 163 patients (147 male; 16 female; mean age 36.8 years) with high-grade acromioclavicular separation (Rockwood type III:
n
= 60; Rockwood type IV: n = 6; Rockwood type V:
n
= 97).
Results
Acromioclavicular separation occurred less often in women than men (1:9). In patients under 35, the most common cause for ACJ dislocation was sporting activity (37.4%). Rockwood type V was observed significantly more often than the other types with 57.5% (Rockwood type III = 36.8%, Rockwood type IV 3.7%). Concomitant pathologies were diagnosed in 39.3% of the patients with that number rising to as much as 57.3% in patients above 35 years. Most common associated injuries were rotator cuff injuries (32.3%), chondral defects (30.6%) and SLAP-lesions (22.6%). Of all patients, 8.6% needed additional reconstructive surgery.
Conclusion
Glenohumeral injuries are a much more common epiphenomenon during acromioclavicular separation than previously ascertained. High risk group for accompanying injuries are patients above 35 years with preexisting degenerative disease. The increasing use of minimally invasive techniques allows for an easier diagnosis and simultaneous treatment of the additional pathologies.
Journal Article
The effect of ankle tape on joint position sense after local muscle fatigue: a randomized controlled trial
by
Klasan, Antonio
,
Heyse, Thomas J.
,
El-Zayat, Bilal Farouk
in
Adult
,
Ankle Injuries - physiopathology
,
Ankle Injuries - prevention & control
2018
Background
Ankle tape is widely used by athletes to prevent ankle sprain. Although there is growing evidence that ankle tape improve joint position sense, but yet it is not clear even if tape improve joint position sense after muscle fatigue, because fatigue impair joint position sense and raise the risk of ankle sprain. The aim of this study is to examine the effect of ankle tape on joint position sense after local muscle fatigue.
Method
This trial is a randomized controlled trial. 34 healthy subjects participated in this trial. Subjects were randomized distributed into two groups: with tape and without tape. Active and passive absolute error and variable error mean values for two target positions of the ankle joint (15° inversions and inversion minus 5°) before and after fatigue protocol consisted of 30 consecutive maximal concentric/concentric contractions of the ankle evertors and invertors. In this trail joint position sense for all subjects was assessed using The Biodex System isokinetic dynamometer 3, this system is used also for fatigue protocol.
Results
For the variable error (VE), significant mean effect was found for active joint position sense in 15° of inversion after muscle fatigue (
P
< 0, 05). It was a significant decrease in the work in the last third of inversion detected (
P
< 0, 05). There was no significant main effect found for fatigue index of eversion.
Conclusion
Ankle tape can improve joint position sense at the fatigue session when joint position sense becomes worse. As a result, ankle tape may be useful to prevent ankle sprain during playing sports. We suggest athletes and individuals at risk of ankle sprain to apply taping before high-load activity.
Trial registration
The study was retrospectively registered on the ISRCTN registry with study ID
ISRCTN30042335
on 12th December 2017.
Journal Article
Ten-year follow-up of a cemented tapered stem
2018
IntroductionThis stem was cleared by the FDA in 2002 and has been implanted in cementless and cemented versions. Despite its long history, there are no long-term clinical results available for the cemented version of this implant. The aim of this study was to provide such data. It was hypothesized that this implant delivers clinical success comparable to other tapered cemented stems.Materials and methodsA total of 113 hip replacements were performed in 106 patients between October 2007 and December 2009 using the cemented version of this stem. The mean age of the patients at operation was 74.8 years (range 50 91 years). The mean follow-up was 8.9 years with only two patients lost to follow-up. Implant survival was determined using the Kaplan Meier analysis.ResultsStem survival with revision for any reason as the endpoint was 96.4% after 10 years. Survival for stem aseptic loosening was 100%. There were no cases of osteolysis. Clinical outcomes, as shown by Harris Hip Scores, were in line with previous investigations and the rate of adverse events was very low.ConclusionsThis is a modern cemented stem with an excellent survival rate and satisfactory functional outcomes. In this cohort, there were no failures related to the stem through the first decade.
Journal Article
Objective Assessment of shoulder mobility with a new 3D gyroscope - a validation study
by
Wolf, Udo
,
El-Zayat, Bilal Farouk
,
Fuchs-Winkelmann, Susanne
in
Arthrometry, Articular - instrumentation
,
Arthrometry, Articular - methods
,
Arthrometry, Articular - standards
2011
Background
Assessment of shoulder mobility is essential for clinical follow-up of shoulder treatment. Only a few high sophisticated instruments for objective measurements of shoulder mobility are available. The interobserver dependency of conventional goniometer measurements is high. In the 1990s an isokinetic measuring system of BIODEX Inc. was introduced, which is a very complex but valid instrument. Since 2008 a new user-friendly system called DynaPort MiniMod TriGyro ShoulderTest-System (DP) is available. Aim of this study is the validation of this measuring instrument using the BIODEX-System.
Methods
The BIODEX is a computerized robotic dynamometer used for isokinetic testing and training of athletes. Because of its size the system needs to be installed in a separated room. The DP is a small, light-weighted three-dimensional gyroscope that is fixed on the distal upper patient arm, recording abduction, flexion and rotation. For direct comparison we fixed the DP on the lever arm of the BIODEX. The accuracy of measurement was determined at different positions, angles and distances from the centre of rotation (COR) as well as different velocities in a radius between 0° - 180° in steps of 20°. All measurements were repeated 10 times. As satisfactory accuracy a difference between both systems below 5° was defined. The statistical analysis was performed with a linear regression model.
Results
The evaluation shows very high accuracy of measurements. The maximum average deviation is below 2.1°. For a small range of motion the DP is slightly underestimating comparing the BIODEX, whereas for higher angles increasing positive differences are observed.
The distance to the COR as well as the position of the DP on the lever arm have no significant influence. Concerning different motion speeds significant but not relevant influence is detected. Unfortunately device related effects are observed, leading to differences between repeated measurements with any two different devices up to 8° at maximal range of motion (180°).
Conclusions
In summary the results shows high correlation and good reproducibility of measurements. All deviations are inside the tolerance interval of 5°, if one device is used. An unlikely systematic device effect is detected. These laboratory trials are promising for the validation of this system in humans. The challenge for both systems will be the changing of the COR in the shoulder joint at elevations higher than 90°.
Journal Article
Comparison between bovine bone and titanium interference screws for implant fixation in ACL reconstruction: a biomechanical study
2010
IntroductionThe application of interference screws for the fixation of bone-patellar tendon-bone (BPTB) grafts is a well-established technique in anterior-cruciate ligament reconstruction. Interference screws derived from bovine compact bone are a biological alternative to metallic or biodegradable polymer interference screws.Materials and methodsIn 60 porcine specimens, the tibial part of an anterior-cruciate ligament reconstruction was performed using a BPTB graft. To secure the graft, either an 8-mm titanium interference screw or a self-made bovine interference screw (BC), or a commercial bovine compact bone screw (Tutofix®) was used. The maximum failure load was determined by means of a universal testing machine with computer interface at a testing speed of 50 mm/min. In a second test series, cyclic sub-maximal load was applied to the test specimen from 40 to 400 N with a number of 1,000 load cycles and a frequency of 1 Hz. Subsequently, the maximum failure load was determined. The stiffness of the test specimen was investigated in both test series. Each type of interference screw was tested 10 times.ResultsA secure fixation of the grafts was achieved with all interference screws. In the experiments on the maximum load to failures, the titanium screws showed significantly higher failure loads than the Tutofix® screws (P = 0.005). The stiffness of the grafts fixed with BC screws was significantly higher as compared to the fixation with Tutofix® screws (P = 0.005). After cyclic sub-maximal loading, the maximum failure load of the titanium screws was significantly higher than that of the Tutofix® screws (P = 0.033). The fixation of the BC screws showed a significantly higher failure load (P = 0.021) and stiffness (P = 0.032) than the Tutofix® screw fixation. Except for two screw head fractures and two intra-tendinous graft ruptures, the failure mode was slippage in the interface between interference screw and bone plug.ConclusionInterference screws derived from bovine compact bone show similar good results as the titanium interference screws. Therefore, the safety and in vivo performance of products derived from xenogenic bone should be the focus of further investigations.
Journal Article
Mono- versus polyaxial locking plates in distal femur fractures – a biomechanical comparison of the Non-Contact-Bridging- (NCB) and the PERILOC-plate
by
Krüger, Antonio
,
Ruchholtz, Steffen
,
Zettl, Ralph
in
Aged
,
Aged, 80 and over
,
Biomechanical Phenomena
2014
Background
The aim of this cadaveric study was to compare a polyaxial (NCB®, Zimmer) to a fixed-angle monoaxial locking plate (PERILOC®, Smith & Nephew) in comminuted fractures of the distal femur regarding stability of the construct. Up to date there is no published biomechanical data concerning polyaxial plating in cadaveric distal femurs.
Methods
Fourteen formalin fixed femora were scanned by dual-energy x-ray absorptiometry. As fracture model an unstable supracondylar comminuted fracture was simulated. Fractures were pairwise randomly fixed either with a mono- (group A) or a polyaxial (group B) distal femur plate. The samples were tested in a servohydraulic mechanical testing system starting with an axial loading of 200 N following an increase of 200 N in every step with 500 cycles in every sequence up to a maximum of 2 000 N. The end points were implant failure or relevant loss of reduction. Data records included for each specimen time, number of cycles, axial load and axial displacement. Statistical analysis was performed using the exact Wilcoxon signed rank test.
Results
The mean donor age at the time of death was 75 years. The bone mass density (BMD) of the femurs in both groups was comparable and showed no statistically significant differences. Five bones failed before reaching the maximum applied force of 2000 N. Distribution curves of all samples in both groups, showing the plastic deformation in relation to the axial force, showed no statistically significant differences.
Conclusions
Operative stabilization of distal femur fractures can be successfully and equally well achieved using either a monoaxial or a polyaxial locking plate. Polyaxial screw fixation may have advantages if intramedullary implants are present.
Journal Article
Results of titanium locking plate and stainless steel cerclage wire combination in femoral fractures
by
Efe, Turgay
,
Ruchholtz, Steffen
,
Kreslo, Dimitri
in
Conservative Orthopedics
,
Fractures
,
Internal fixation in fractures
2013
Background:
Some
in vitro
studies warn combining different metals in orthopedic surgery. The aim of this study is to determine the impact of combining titanium and stainless steel on bone healing and the clinical course of patients undergoing internal fxation of femoral fractures.
Materials and Methods:
69 patients with femoral fractures had polyaxial locking plate osteosynthesis. The locking plate was made of a titanium alloy. Two different cohorts were defned: (a) sole plating and (b) additional stainless steel cerclage wiring. Postoperative radiographs and clinical followup were performed at 6 weeks, 3 months and 12 months.
Results:
Cohorts A and B had 36 and 33 patients, respectively. Patient demographics and comorbidities were similar in both groups. In two cases in cohort A, surgical revision was necessary. No complication could be attributed to the combination of titanium and stainless steel.
Conclusion:
The combination of stainless steel cerclage wires and titanium plates does not compromise fracture healing or the postoperative clinical course.
Journal Article
Objective assessment, repeatability, and agreement of shoulder ROM with a 3D gyroscope
by
El-Zayat, Bilal Farouk
,
Fuchs-Winkelmann, Susanne
,
Timmesfeld, Nina
in
Adult
,
Agreements
,
Arthrometry, Articular - instrumentation
2013
Background
Assessment of shoulder mobility is essential for diagnosis and clinical follow-up of shoulder diseases. Only a few highly sophisticated instruments for objective measurements of shoulder mobility are available. The recently introduced DynaPort MiniMod TriGyro ShoulderTest-System (DP) was validated earlier in laboratory trials. We aimed to assess the precision (repeatability) and agreement of this instrument in human subjects, as compared to the conventional goniometer.
Methods
The DP is a small, light-weight, three-dimensional gyroscope that can be fixed on the distal upper arm, recording shoulder abduction, flexion, and rotation. Twenty-one subjects (42 shoulders) were included for analysis. Two subsequent assessments of the same subject with a 30-minute delay in testing of each shoulder were performed with the DP in two directions (flexion and abduction), and simultaneously correlated with the measurements of a conventional goniometer. All assessments were performed by one observer. Repeatability for each method was determined and compared as the statistical variance between two repeated measurements. Agreement was illustrated by Bland-Altman-Plots with 95% limits of agreement. Statistical analysis was performed with a linear mixed regression model. Variance for repeated measurements by the same method was also estimated and compared with the likelihood-ratio test.
Results
Evaluation of abduction showed significantly better repeatability for the DP compared to the conventional goniometer (error variance: DP = 0.89, goniometer = 8.58, p = 0.025). No significant differences were found for flexion (DP = 1.52, goniometer = 5.94, p = 0.09). Agreement assessment was performed for flexion for mean differences of 0.27° with 95% limit of agreement ranging from −7.97° to 8.51°. For abduction, the mean differences were 1.19° with a 95% limit of agreement ranging from −9.07° to 11.46°.
Conclusion
In summary, DP demonstrated a high precision even higher than the conventional goniometer. Agreement between both methods is acceptable, with possible deviations of up to greater than 10°. Therefore, static measurements with DP are more precise than conventional goniometer measurements. These results are promising for routine clinical use of the DP.
Journal Article
An ex vivo continuous passive motion model in a porcine knee for assessing primary stability of cell-free collagen gel plugs
by
Füglein, Alexander
,
Fuchs-Winkelmann, Susanne
,
El-Zayat, Bilal Farouk
in
Animals
,
Biomechanical Phenomena
,
Cartilage
2010
Background
Primary stability of cartilage repair constructs is of the utmost importance in the clinical setting but few continuous passive motion (CPM) models are available. Our study aimed to establish a novel ex vivo CPM animal model and to evaluate the required motion cycles for testing the mechanical properties of a new cell-free collagen type I gel plug (CaReS
®
-1S).
Methods
A novel ex vivo CPM device was developed. Full-thickness cartilage defects (11 mm diameter by 6 mm deep) were created on the medial femoral condyle of porcine knee specimens. CaReS
®
-1S was implanted in 16 animals and each knee underwent continuous passive motion. After 0, 2000, 4000, 6000, and 8000 motions, standardized digital pictures of the grafts were taken, focusing on the worn surfaces. The percentage of worn surface on the total CaReS
®
-1S surface was evaluated with image processing software.
Results
Significant differences in the worn surface were recorded between 0 and 2000 motion cycles (p < 0.0001). After 2000 motion cycles, there was no significant difference. No total delamination of CaReS
®
-1S with an empty defect site was recorded.
Conclusion
The ex vivo CPM animal model is appropriate in investigating CaReS
®
-1S durability under continuous passive motion. 2000 motion cycles appear adequate to assess the primary stability of type I collagen gels used to repair focal chondral defects.
Journal Article