Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
57 result(s) for "Felkai, R"
Sort by:
Fluorescence imaging of individual ions and molecules in pressurized noble gases for barium tagging in 136Xe
The imaging of individual Ba 2+ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba 2+ ion imaging inside a high-pressure xenon gas environment. Ba 2+ ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with scan area of 1 × 1 cm 2 located inside 10 bar of xenon gas. This form of microscopy represents key ingredient in the development of barium tagging for neutrinoless double beta decay searches in 136 Xe. This also provides a new tool for studying the photophysics of fluorescent molecules and chemosensors at the solid-gas interface to enable bottom-up design of catalysts and sensors. Barium tagging is a key ingredient for future detectors of neutrinoless double beta decay in low-background environments. Here, the authors demonstrate fluorescence imaging of single Ba2+ ions in high pressure Xenon gas, by comparing activity between Ba2+ chelated and unchelated samples of crown-ether chemosensors.
First results of the NEXT-100 detector using 83mKr decays
The NEXT collaboration is investigating the double beta decay of 136 X e using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from 83 m Kr decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for 83 m Kr point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an E - 1 / 2 extrapolation to Q β β yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.
The NEXT-100 Detector
The NEXT collaboration is dedicated to the study of double beta decays of 136Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution (≤ 1% FWHM at the Qββ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at 4 bar and drift fields of 74 V cm–1 and 118 V cm–1, respectively. Alpha decays from the 222Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.
Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging
If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T1 and T2. In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average c̅o̅s̅ ̅θ̅ and T̅₁̅ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.
Performance of an optical TPC Geant4 simulation with opticks GPU-accelerated photon propagation
We investigate the performance of Opticks, a NVIDIA OptiX API 7.5 GPU-accelerated photon propagation tool compared with a single-threaded Geant4 simulation. We compare the simulations using an improved model of the NEXT-CRAB-0 gaseous time projection chamber. Performance results suggest that Opticks improves simulation speeds by between 58.47 ± 0.02 and 181.39 ± 0.28 times relative to a CPU-only Geant4 simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between Opticks and Geant4.
Fluorescence imaging of individual ions and molecules in pressurized noble gases for barium tagging in 136Xe
The imaging of individual Ba2+ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba2+ ion imaging inside a high-pressure xenon gas environment. Ba2+ ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with scan area of 1 × 1 cm2 located inside 10 bar of xenon gas. This form of microscopy represents key ingredient in the development of barium tagging for neutrinoless double beta decay searches in 136Xe. This also provides a new tool for studying the photophysics of fluorescent molecules and chemosensors at the solid-gas interface to enable bottom-up design of catalysts and sensors.
Neutral Bremsstrahlung Emission in Xenon Unveiled
We present evidence of non-excimer-based secondary scintillation in gaseous xenon, obtained using both the NEXT-White time projection chamber (TPC) and a dedicated setup. Detailed comparison with first-principle calculations allows us to assign this scintillation mechanism to neutral bremsstrahlung (NBrS), a process that is postulated to exist in xenon that has been largely overlooked. For photon emission below 1000 nm, the NBrS yield increases from about10−2photon/e−cm−1bar−1at pressure-reduced electric field values of50Vcm−1bar−1to above3×10−1photon/e−cm−1bar−1at500Vcm−1bar−1. Above1.5kVcm−1bar−1, values that are typically employed for electroluminescence, it is estimated that NBrS is present with an intensity around1photon/e−cm−1bar−1, which is about 2 orders of magnitude lower than conventional, excimer-based electroluminescence. Despite being fainter than its excimeric counterpart, our calculations reveal that NBrS causes luminous backgrounds that can interfere, in either gas or liquid phase, with the ability to distinguish and/or to precisely measure low primary-scintillation signals (S1). In particular, we show this to be the case in the “buffer” region, where keeping the electric field below the electroluminescence threshold does not suffice to extinguish secondary scintillation. The electric field leakage in this region should be mitigated to avoid intolerable levels of NBrS emission. Furthermore, we show that this new source of light emission opens up a viable path toward obtaining S2 signals for discrimination purposes in future single-phase liquid TPCs for neutrino and dark matter physics, with estimated yields up to20–50photons/e−cm−1.
Sensitivity of a tonne-scale NEXT detector for neutrinoless double-beta decay searches
The Neutrino Experiment with a Xenon TPC (NEXT) searches for the neutrinoless double-beta (0νββ) decay of 136Xe using high-pressure xenon gas TPCs with electroluminescent amplification. A scaled-up version of this technology with about 1 tonne of enriched xenon could reach in less than 5 years of operation a sensitivity to the half-life of 0νββ decay better than 1027 years, improving the current limits by at least one order of magnitude. This prediction is based on a well-understood background model dominated by radiogenic sources. The detector concept presented here represents a first step on a compelling path towards sensitivity to the parameter space defined by the inverted ordering of neutrino masses, and beyond.
Development of a Multi-Purpose Optical TPC for Neutron-Induced Reaction Studies at SARAF
Neutron-induced reactions play a central role in stellar and Big Bang nucleosynthesis models. Yet many of the cross sections remain poorly constrained at astrophysically relevant energies. To address these needs, we are developing a multi-purpose Optical Time Projection Chamber (OTPC) optimized for precision neutron-reaction studies at the Soreq Applied Research Accelerator Facility (SARAF) upcoming high-intensity, time-of-flight neutron beam. The detector combines a drift chamber filled with CF4-based scintillating gas mixtures, fast photodetectors for prompt scintillation detection, and high-speed optical readout of avalanche-induced secondary scintillation to enable full 3D reconstruction of charged-particle tracks. A prototype system has been assembled and tested. This has enabled systematic characterization of electron drift velocity, charge and light amplification, and 2D optical imaging of alpha-particle tracks in an Ar/CF4 gas mixture. These studies guide the design of a larger, fully integrated OTPC system intended for operation at SARAF. In parallel, we are exploring advanced image sensors to further enhance tracking resolution. We report on recent progress with the prototype and outline the next steps toward commissioning the full system.
Design, characterization and installation of the NEXT-100 cathode and electroluminescence regions
NEXT-100 is currently being constructed at the Laboratorio Subterráneo de Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg of xenon. Charge amplification is carried out via electroluminescence (EL) which is the process of accelerating electrons in a high electric field region causing secondary scintillation of the medium proportional to the initial charge. The NEXT-100 EL and cathode regions are made from tensioned hexagonal meshes of 1 m diameter. This paper describes the design, characterization, and installation of these parts for NEXT-100. Simulations of the electric field are performed to model the drift and amplification of ionization electrons produced in the detector under various EL region alignments and rotations. Measurements of the electrostatic breakdown voltage in air characterize performance under high voltage conditions and identify breakdown points. The electrostatic deflection of the mesh is quantified and fit to a first-principles mechanical model. Measurements were performed with both a standalone test EL region and with the NEXT-100 EL region before its installation in the detector. Finally, we describe the parts as installed in NEXT-100, following their deployment in Summer 2023.