Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
2
result(s) for
"Fidopiastis, Niki"
Sort by:
Radiation Sterilization: Dose Is Dose
by
Bryans, Trabue
,
Fidopiastis, Niki
,
Luebke, Michelle
in
Deactivation
,
Dosimetry
,
Electron beams
2020
In the radiation sterilization arena, the question often arises as to whether radiation resistance of microorganisms might be affected by the energy level of the radiation source and the rate of the dose delivered (kGy/time). The basis for the question is if the microbial lethality is affected by the radiation energy level and/or the rate the dose is delivered, then the ability to transfer dose among different radiation sources could be challenged. This study addressed that question by performing a microbial inactivation study using two radiation sources (gamma and electron beam [E-beam]), two microbial challenges (natural product bioburden and biological indicators), and four dose rates delivered by three energy levels (1.17 MeV [gamma], 1.33 MeV [gamma], and 10 MeV [high-energy E-beam]). Based on analysis of the data, no significant differences were seen in the rate of microbial lethality across the range of radiation energies evaluated. In summary, as long as proof exists that the specified dose is delivered, dose is dose.
Journal Article