Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
56 result(s) for "Formica, Domenico"
Sort by:
Performance Evaluation of Bluetooth Low Energy: A Systematic Review
Small, compact and embedded sensors are a pervasive technology in everyday life for a wide number of applications (e.g., wearable devices, domotics, e-health systems, etc.). In this context, wireless transmission plays a key role, and among available solutions, Bluetooth Low Energy (BLE) is gaining more and more popularity. BLE merges together good performance, low-energy consumption and widespread diffusion. The aim of this work is to review the main methodologies adopted to investigate BLE performance. The first part of this review is an in-depth description of the protocol, highlighting the main characteristics and implementation details. The second part reviews the state of the art on BLE characteristics and performance. In particular, we analyze throughput, maximum number of connectable sensors, power consumption, latency and maximum reachable range, with the aim to identify what are the current limits of BLE technology. The main results can be resumed as follows: throughput may theoretically reach the limit of ~230 kbps, but actual applications analyzed in this review show throughputs limited to ~100 kbps; the maximum reachable range is strictly dependent on the radio power, and it goes up to a few tens of meters; the maximum number of nodes in the network depends on connection parameters, on the network architecture and specific device characteristics, but it is usually lower than 10; power consumption and latency are largely modeled and analyzed and are strictly dependent on a huge number of parameters. Most of these characteristics are based on analytical models, but there is a need for rigorous experimental evaluations to understand the actual limits.
Smart Sensors for Healthcare and Medical Applications
This special issue on \"Smart Sensors for Healthcare and Medical Applications\" focuses on new sensing technologies, measurement techniques, and their applications in medicine and healthcare [...].This special issue on \"Smart Sensors for Healthcare and Medical Applications\" focuses on new sensing technologies, measurement techniques, and their applications in medicine and healthcare [...].
Non-Contact Monitoring of Breathing Pattern and Respiratory Rate via RGB Signal Measurement
Among all the vital signs, respiratory rate remains the least measured in several scenarios, mainly due to the intrusiveness of the sensors usually adopted. For this reason, all contactless monitoring systems are gaining increasing attention in this field. In this paper, we present a measuring system for contactless measurement of the respiratory pattern and the extraction of breath-by-breath respiratory rate. The system consists of a laptop’s built-in RGB camera and an algorithm for post-processing of acquired video data. From the recording of the chest movements of a subject, the analysis of the pixel intensity changes yields a waveform indicating respiratory pattern. The proposed system has been tested on 12 volunteers, both males and females seated in front of the webcam, wearing both slim-fit and loose-fit t-shirts. The pressure-drop signal recorded at the level of nostrils with a head-mounted wearable device was used as reference respiratory pattern. The two methods have been compared in terms of mean of absolute error, standard error, and percentage error. Additionally, a Bland–Altman plot was used to investigate the bias between methods. Results show the ability of the system to record accurate values of respiratory rate, with both slim-fit and loose-fit clothing. The measuring system shows better performance on females. Bland–Altman analysis showed a bias of −0.01 breaths · min − 1 , with respiratory rate values between 10 and 43 breaths · min − 1 . Promising performance has been found in the preliminary tests simulating tachypnea.
On the Orientation Error of IMU: Investigating Static and Dynamic Accuracy Targeting Human Motion
The accuracy in orientation tracking attainable by using inertial measurement units (IMU) when measuring human motion is still an open issue. This study presents a systematic quantification of the accuracy under static conditions and typical human dynamics, simulated by means of a robotic arm. Two sensor fusion algorithms, selected from the classes of the stochastic and complementary methods, are considered. The proposed protocol implements controlled and repeatable experimental conditions and validates accuracy for an extensive set of dynamic movements, that differ in frequency and amplitude of the movement. We found that dynamic performance of the tracking is only slightly dependent on the sensor fusion algorithm. Instead, it is dependent on the amplitude and frequency of the movement and a major contribution to the error derives from the orientation of the rotation axis w.r.t. the gravity vector. Absolute and relative errors upper bounds are found respectively in the range [0.7° ÷ 8.2°] and [1.0° ÷ 10.3°]. Alongside dynamic, static accuracy is thoroughly investigated, also with an emphasis on convergence behavior of the different algorithms. Reported results emphasize critical issues associated with the use of this technology and provide a baseline level of performance for the human motion related application.
A multi-point heart rate monitoring using a soft wearable system based on fiber optic technology
Early diagnosis can be crucial to limit both the mortality and economic burden of cardiovascular diseases. Recent developments have focused on the continuous monitoring of cardiac activity for a prompt diagnosis. Nowadays, wearable devices are gaining broad interest for a continuous monitoring of the heart rate (HR). One of the most promising methods to estimate HR is the seismocardiography (SCG) which allows to record the thoracic vibrations with high non-invasiveness in out-of-laboratory settings. Despite significant progress on SCG, the current state-of-the-art lacks both information on standardized sensor positioning and optimization of wearables design. Here, we introduce a soft wearable system (SWS), whose novel design, based on a soft polymer matrix embedding an array of fiber Bragg gratings, provides a good adhesion to the body and enables the simultaneous recording of SCG signals from multiple measuring sites. The feasibility assessment on healthy volunteers revealed that the SWS is a suitable wearable solution for HR monitoring and its performance in HR estimation is strongly influenced by sensor positioning and improved by a multi-sensor configuration. These promising characteristics open the possibility of using the SWS in monitoring patients with cardiac pathologies in clinical (e.g., during cardiac magnetic resonance procedures) and everyday life settings.
Modulation of brain plasticity in stroke: a novel model for neurorehabilitation
Key Points Noninvasive brain stimulation (NIBS) is a promising approach to enhance recovery after stroke, but its beneficial effect is limited and the technique is not yet ready for broad clinical use We suggest that the disappointments in NIBS trials are related to over-reliance on the interhemispheric competition and vicariation models of recovery, which are oversimplified and do not apply to all patients with stroke The concept of 'structural reserve' integrates the effects that interhemispheric inhibition and vicariation exert on the unlesioned residual network We propose a unified 'bimodal balance–recovery model' that takes into account this individual residual network The model could be used to tailor treatment for individual patients and increase the efficacy of NIBS in stroke rehabilitation Noninvasive brain stimulation (NIBS) is a promising approach for facilitating recovery of motor function after stroke, but trials assessing its efficacy have provided contradictory results. Di Pino and colleagues propose a unified 'bimodal balance–recovery model' for stroke recovery that takes into account the individual residual structural reserve and could aid tailoring of treatment for individual patients, thereby increasing the efficacy of NIBS in stroke rehabilitation. Noninvasive brain stimulation (NIBS) techniques can be used to monitor and modulate the excitability of intracortical neuronal circuits. Long periods of cortical stimulation can produce lasting effects on brain function, paving the way for therapeutic applications of NIBS in chronic neurological disease. The potential of NIBS in stroke rehabilitation has been of particular interest, because stroke is the main cause of permanent disability in industrial nations, and treatment outcomes often fail to meet the expectations of patients. Despite promising reports from many clinical trials on NIBS for stroke recovery, the number of studies reporting a null effect remains a concern. One possible explanation is that the interhemispheric competition model—which posits that suppressing the excitability of the hemisphere not affected by stroke will enhance recovery by reducing interhemispheric inhibition of the stroke hemisphere, and forms the rationale for many studies—is oversimplified or even incorrect. Here, we critically review the proposed mechanisms of synaptic and functional reorganization after stroke, and suggest a bimodal balance–recovery model that links interhemispheric balancing and functional recovery to the structural reserve spared by the lesion. The proposed model could enable NIBS to be tailored to the needs of individual patients.
A Wearable System with Embedded Conductive Textiles and an IMU for Unobtrusive Cardio-Respiratory Monitoring
The continuous and simultaneous monitoring of physiological parameters represents a key aspect in clinical environments, remote monitoring and occupational settings. In this regard, respiratory rate (RR) and heart rate (HR) are correlated with several physiological and pathological conditions of the patients/workers, and with environmental stressors. In this work, we present and validate a wearable device for the continuous monitoring of such parameters. The proposed system embeds four conductive sensors located on the user’s chest which allow retrieving the breathing activity through their deformation induced during cyclic expansion and contraction of the rib cage. For monitoring HR we used an embedded IMU located on the left side of the chest wall. We compared the proposed device in terms of estimating HR and RR against a reference system in three scenarios: sitting, standing and supine. The proposed system reliably estimated both RR and HR, showing low error averaged along subjects in all scenarios. This is the first study focused on the feasibility assessment of a wearable system based on a multi-sensor configuration (i.e., conductive sensors and IMU) for RR and HR monitoring. The promising results encourage the application of this approach in clinical and occupational settings.
Comparing end-effector position and joint angle feedback for online robotic limb tracking
Somatosensation greatly increases the ability to control our natural body. This suggests that supplementing vision with haptic sensory feedback would also be helpful when a user aims at controlling a robotic arm proficiently. However, whether the position of the robot and its continuous update should be coded in a extrinsic or intrinsic reference frame is not known. Here we compared two different supplementary feedback contents concerning the status of a robotic limb in 2-DoFs configuration: one encoding the Cartesian coordinates of the end-effector of the robotic arm (i.e., Task-space feedback ) and another and encoding the robot joints angles (i.e., Joint-space feedback ). Feedback was delivered to blindfolded participants through vibrotactile stimulation applied on participants’ leg. After a 1.5-hour training with both feedbacks, participants were significantly more accurate with Task compared to Joint-space feedback , as shown by lower position and aiming errors , albeit not faster (i.e., similar onset delay ). However, learning index during training was significantly higher in Joint space feedback compared to Task-space feedback . These results suggest that Task-space feedback is probably more intuitive and more suited for activities which require short training sessions, while Joint space feedback showed potential for long-term improvement. We speculate that the latter, despite performing worse in the present work, might be ultimately more suited for applications requiring long training, such as the control of supernumerary robotic limbs for surgical robotics, heavy industrial manufacturing, or more generally, in the context of human movement augmentation.
Comparison between Chest-Worn Accelerometer and Gyroscope Performance for Heart Rate and Respiratory Rate Monitoring
The demand for wearable devices to simultaneously monitor heart rate (HR) and respiratory rate (RR) values has grown due to the incidence increase in cardiovascular and respiratory diseases. The use of inertial measurement unit (IMU) sensors, embedding both accelerometers and gyroscopes, may ensure a non-intrusive and low-cost monitoring. While both accelerometers and gyroscopes have been assessed independently for both HR and RR monitoring, there lacks a comprehensive comparison between them when used simultaneously. In this study, we used both accelerometers and gyroscopes embedded in a single IMU sensor for the simultaneous monitoring of HR and RR. The following main findings emerged: (i) the accelerometer outperformed the gyroscope in terms of accuracy in both HR and RR estimation; (ii) the window length used to estimate HR and RR values influences the accuracy; and (iii) increasing the length over 25 s does not provide a relevant improvement, but accuracy improves when the subject is seated or lying down, and deteriorates in the standing posture. Our study provides a comprehensive comparison between two promising systems, highlighting their potentiality for real-time cardiorespiratory monitoring. Furthermore, we give new insights into the influence of window length and posture on the systems’ performance, which can be useful to spread this approach in clinical settings.
Cardio-Respiratory Monitoring in Archery Using a Smart Textile Based on Flexible Fiber Bragg Grating Sensors
In precision sports, the control of breathing and heart rate is crucial to help the body to remain stable in the shooting position. To improve stability, archers try to adopt similar breathing patterns and to have a low heartbeat during each shot. We proposed an easy-to-use and unobtrusive smart textile (ST) which is able to detect chest wall excursions due to breathing and heart beating. The sensing part is based on two FBGs housed into a soft polymer matrix to optimize the adherence to the chest wall and the system robustness. The ST was assessed on volunteers to figure out its performance in the estimation of respiratory frequency (fR) and heart rate (HR). Then, the system was tested on two archers during four shooting sessions. This is the first study to monitor cardio-respiratory activity on archers during shooting. The good performance of the ST is supported by the low mean absolute percentage error for fR and HR estimation (≤1.97% and ≤5.74%, respectively), calculated with respect to reference signals (flow sensor for fR, photopletismography sensor for HR). Moreover, results showed the capability of the ST to estimate fR and HR during different phases of shooting action. The promising results motivate future investigations to speculate about the influence of fR and HR on archers’ performance.