Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
59
result(s) for
"G. Haefeli"
Sort by:
A scintillating fibre beam profile monitor for the experimental areas of the SPS at CERN
2016
The CERN Super Proton Synchrotron (SPS) delivers a wide spectrum of particle beams (hadrons, leptons and heavy ions) that can vary greatly in momentum and intensity. The profile and position of these beams are measured using particle detectors. However, the current systems show several problems that limit the quality of such monitoring. We have researched a new monitor made of scintillating fibres read-out with Silicon Photomultipliers (SiPM), which has the potential to perform better in terms of material budget, range of intensities measured and available detector size. In addition, it also has particle counting capabilities, extending its use to spectrometry or Time-Of-Flight measurements. Its radiation hardness is good to guarantee years of functioning. We have successfully tested a first prototype of this detector with different particle beams at CERN, giving accurate profile measurements over a wide range of energies and intensities. It only showed problems during operation with lead ion beams, believed to come from crosstalk between the fibres. Investigations are ongoing on alternative photodetectors, the electronics readout and solutions to the fibre crosstalk.
Journal Article
Noninvasive LHC transverse beam size measurement using inelastic beam-gas interactions
by
Würkner, B.
,
Jacobsson, R.
,
Kuonen, A.
in
Large Hadron Collider
,
Luminosity
,
Measuring instruments
2019
The beam-gas vertex (BGV) detector is an innovative instrument measuring noninvasively the transverse beam size in the Large Hadron Collider (LHC) using reconstructed tracks from beam-gas interactions. The BGV detector was installed in 2016 as part of the R&D for the High-Luminosity LHC project. It allows beam size measurements throughout the LHC acceleration cycle with high-intensity physics beams. A precision better than 2% with an integration time of less than 30 s is obtained on the average beam size measured, while the transverse size of individual proton bunches is measured with a resolution of 5% within 5 min. Particles emerging from beam-gas interactions in a specially developed gas volume along the beam direction are recorded by two tracking stations made of scintillating fibers. A scintillator trigger system selects, on-line, events with tracks originating from the interaction region. All the detector elements are located outside the beam vacuum pipe to simplify the design and minimize interference with the accelerated particle beam. The beam size measurement results presented here are based on the correlation between tracks originating from the same beam-gas interaction vertex.
Journal Article
Erratum to: Measurement of $$\\psi (2S)$$ ψ(2S) meson production in pp collisions at $$\\sqrt{s}=7\\,\\hbox {TeV}$$ s=7TeV
2020
This erratum corrects measurements of the prompt and secondary (from-b).
Journal Article
First LHC transverse beam size measurements with the beam gas vertex detectorResearch supported by the HL-LHC project
2017
The Beam Gas Vertex detector (BGV) is an innovative beam profile monitor based on the reconstruction of beam-gas interaction vertices which is being developed as part of the High Luminosity LHC project. Tracks are identified using several planes of scintillating fibres, located outside the beam vacuum chamber and perpendicular to the beam axis. The gas pressure in the interaction volume is adjusted such as to provide an adequate trigger rate, without disturbing the beam. A BGV demonstrator monitoring one of the two LHC beams was fully installed and commissioned in 2016. First data and beam size measurements show that the complete detector and data acquisition system is operating as expected. The BGV operating parameters are now being optimised and the reconstruction algorithms developed to produce accurate and fast reconstruction on a CPU farm in order to provide real time beam profile measurements to the LHC operators.
Journal Article
First LHC transverse beam size measurements with the beam gas vertex detector Research supported by the HL-LHC project
2017
The Beam Gas Vertex detector (BGV) is an innovative beam profile monitor based on the reconstruction of beam-gas interaction vertices which is being developed as part of the High Luminosity LHC project. Tracks are identified using several planes of scintillating fibres, located outside the beam vacuum chamber and perpendicular to the beam axis. The gas pressure in the interaction volume is adjusted such as to provide an adequate trigger rate, without disturbing the beam. A BGV demonstrator monitoring one of the two LHC beams was fully installed and commissioned in 2016. First data and beam size measurements show that the complete detector and data acquisition system is operating as expected. The BGV operating parameters are now being optimised and the reconstruction algorithms developed to produce accurate and fast reconstruction on a CPU farm in order to provide real time beam profile measurements to the LHC operators.
Journal Article
The LHCb Silicon Tracker – Control system specific tools and challenges
The Experiment Control System (ECS) of the LHCb Silicon Tracker sub-detectors is built on the integrated LHCb ECS framework. Although all LHCb sub-detectors use the same framework and follow the same guidelines, the Silicon Tracker control system uses some interesting additional features for operation and monitoring. The main details are described in this document. Since its design, the Silicon Tracker control system has been continuously evolving in a quite disorganized way. Some major maintenance activities are required in order to keep improving it. A description of those activities can also be found here.
Journal Article
Performance of the LHCb Vertex Locator
2014
The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system is operated in vacuum, uses a bi-phase CO2 cooling system, and the sensors are moved to 7 mm from the LHC beam for physics data taking. The performance and stability of these characteristic features of the detector are described, and details of the material budget are given. The calibration of the timing and the data processing algorithms that are implemented in FPGAs are described. The system performance is fully characterised. The sensors have a signal to noise ratio of approximately 20 and a best hit resolution of 4 microns is achieved at the optimal track angle. The typical detector occupancy for minimum bias events in standard operating conditions in 2011 is around 0.5%, and the detector has less than 1% of faulty strips. The proximity of the detector to the beam means that the inner regions of the n+-on-n sensors have undergone space-charge sign inversion due to radiation damage. The VELO performance parameters that drive the experiment's physics sensitivity are also given. The track finding efficiency of the VELO is typically above 98% and the modules have been aligned to a precision of 1 micron for translations in the plane transverse to the beam. A primary vertex resolution of 13 microns in the transverse plane and 71 microns along the beam axis is achieved for vertices with 25 tracks. An impact parameter resolution of less than 35 microns is achieved for particles with transverse momentum greater than 1 GeV/c.
Performance of the LHCb muon system
2013
The performance of the LHCb Muon system and its stability across the full 2010 data taking with LHC running at ps = 7 TeV energy is studied. The optimization of the detector setting and the time calibration performed with the first collisions delivered by LHC is described. Particle rates, measured for the wide range of luminosities and beam operation conditions experienced during the run, are compared with the values expected from simulation. The space and time alignment of the detectors, chamber efficiency, time resolution and cluster size are evaluated. The detector performance is found to be as expected from specifications or better. Notably the overall efficiency is well above the design requirements
A multidomain intervention against cognitive decline in an at‐risk‐population in Germany: Results from the cluster‐randomized AgeWell.de trial
by
König, Hans‐Helmut
,
Czock, David
,
Luppa, Melanie
in
Activities of daily living
,
Adults
,
Aging
2024
INTRODUCTION We investigated the effectiveness of a multidomain intervention to preserve cognitive function in older adults at risk for dementia in Germany in a cluster‐randomized trial. METHODS Individuals with a Cardiovascular Risk Factors, Aging, and Dementia (CAIDE) risk score ≥ 9 aged 60 to 77 years were recruited. After randomization of their general practitioner (GP), patients received a multidomain intervention (including optimization of nutrition and medication, and physical, social, and cognitive activity) or general health advice and GP treatment as usual over 24 months. Primary outcome was global cognitive performance (composite z score, based on domain‐specific neuropsychological tests). RESULTS Of 1030 participants at baseline, n = 819 completed the 24‐month follow‐up assessment. No differences regarding global cognitive performance (average marginal effect = 0.010, 95% confidence interval: –0.113, 0.133) were found between groups at follow‐up. Perceived restrictions in intervention conduct by the COVID‐19 pandemic did not impact intervention effectiveness. DISCUSSION The intervention did not improve global cognitive performance. Highlights Overall, no intervention effects on global cognitive performance were detected. The multidomain intervention improved health‐related quality of life in the total sample. In women, the multidomain intervention reduced depressive symptoms. The intervention was completed during the COVID‐19 pandemic.
Journal Article