Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
47 result(s) for "Gao, Guo-Xuan"
Sort by:
Comparing outcomes of single-port insufflation endoscopic breast-conserving surgery and conventional open approach for breast cancer
Background In the surgical treatment of breast cancer, the goal of surgeons is to continually create and improve minimally invasive surgical techniques to increase patients’ quality of life. Currently, routine breast-conserving surgery is often performed using two obvious incisions. Here, we compare the clinical efficacy and aesthetic outcomes of a novel technique using one incision, called ‘single-port insufflation endoscopic breast-conserving surgery’ (SIE-BCS), vs. conventional breast-conserving surgery (C-BCS) in patients with early-stage breast cancer. Methods A total of 180 patients with stage I or stage II breast cancer participated in this study, of whom 63 underwent SIE-BCS and 117 underwent C-BCS. Logistic regression analysis was conducted to assess the risk of local recurrence and metastasis. Aesthetic outcomes were evaluated using the BREAST-Q scale. Results The mean operation time was significantly longer for SIE-BCS (194.9 ± 71.5 min) than for C-BCS (140.3 ± 56.9 min), but the mean incision length was significantly shorter for SIE-BCS than for C-BCS (3.4 ± 1.2 cm vs. 8.6 ± 2.3 cm). While both surgeries yielded similar BREAST-Q ratings for satisfaction with breasts and sexual well-being, SIE-BCS was associated with significantly better ratings for physical well-being (chest area) and psychological well-being. Additionally, SIE-BCS was associated with decreased rates of adverse effects of radiation. The preliminary analysis showed that SIE-BCS did not increase the risk of local recurrence or metastasis. Conclusion The novel single-port insufflation endoscopic assisted BCS technique is feasible, safe, and improves patients’ postoperative comfort and psychological well-being, as compared to the conventional technique.
Prognostic value of tumor-infiltrating lymphocyte subtypes in residual tumors of patients with triple-negative breast cancer after neoadjuvant chemotherapy
After neoadjuvant chemotherapy (NAC), non-pathological complete response of breast cancer patients can benefit from tailored adjuvant chemotherapy. However, it is difficult to select patients with poorer prognosis for additional adjuvant chemotherapy to maximize the benefits. Our study aimed to explore whether the subtypes of tumor-infiltrating lymphocytes (TILs) in residual tumors (RT) is related to the prognosis of triple-negative breast cancer (TNBC) after NAC. Data from patients with primary TNBC consecutively diagnosed at the Breast Disease Center of Peking University First Hospital from 2008 to 2014 were retrieved, and the cases with RT in the breast after NAC were enrolled. TILs subtypes in RT were observed by double-staining immunohistochemistry, and counted with the median TILs value per square millimeter as the cut-off to define high versus low TILs density in each subtype. The relationships between the TIL density of each subgroup and the clinicopathological characteristics of the RT after NAC patients were analyzed by Fisher exact test. Disease-free survival (DFS) and overall survival (OS) were analyzed by the Kaplan-Meier method and log-rank statistics. A total of 37 eligible patients were included in this study, and the median follow-up period was 50 months (range 17-106 months). There was no significant correlation between the infiltrate density of CD4, CD8, CD20, and CD68 lymphocytes and clinic-pathological characteristics. Significantly better prognosis was observed in patients with high CD4-TILs (DFS: P = 0.005, OS: P = 0.021) and high CD8-TILs (DFS: P = 0.018) and low CD20-TILs (OS: P = 0.042). Further analysis showed that patients with CD4/CD20 ratio greater than 1 (DFS: P = 0.001, OS: P = 0.002) or CD8/CD20 ratio greater than 1 (DFS: P = 0.009, OS: P = 0.022) had a better prognosis. Subtypes of TILs in RT is a potential predictive biomarker of survival in TNBC patients after NAC.
Single-port nipple-sparing subcutaneous mastectomy with immediate prosthetic breast reconstruction for breast cancer
IntroductionThis study compares the perioperative results, aesthetic outcome and oncologic safety of single-port insufflation endoscopic nipple-sparing subcutaneous mastectomy combined with immediate reconstruction using prosthesis implantation (SIE-NSM-IRPI) with those of conventional open-nipple and areola-sparing subcutaneous mastectomy combined with immediate reconstruction using prosthesis implantation (C-NSM-IRPI).MethodsIn this retrospective cohort study, 64 early-stage breast cancer patients were divided into SIE-NSM-IRPI (n = 38) and C-NSM-IRPI (n = 26) groups. Perioperative results (operation time, intraoperative blood loss, incision length, drainage duration, and recent complications) were then compared between the two groups. Differences in satisfaction with the breasts, psychosocial well-being, physical well-being (chest) and sexual well-being were analyzed according to the BREAST-Q scale, and survival outcomes were also compared.ResultsThe median follow-up time was 51.5 months. The incision length of SIE-NSM-IRPI was shorter than that of C-NSM-IRPI (P < 0.001). SIE-NSM-IRPI achieved the same detection rate and median number of sentinel lymph nodes as C-NSM-IRPI (3.00vs. 4.00, P = 0.780). The incidence of prosthesis removal due to infection or prosthesis exposure in the SIE-NSM-IRPI group was lower than that in the C-NSM-IRPI group (P = 0.015). Satisfaction with breasts (82.00vs.59.00, P < 0.001), psychosocial well-being (93.00vs.77.00, P = 0.001) and physical well-being (chest) (89.00vs.82.00, P < 0.001) scores were higher in the SIE-NSM-IRPI group. There were no significant differences between the two groups in disease-free survival (hazard ratio = 0.829, 95% confidence interval = 0.182–3.779) and overall survival (hazard ratio = 1.919, 95% confidence interval = 0.169–21.842).ConclusionIn this selected cohort of patients with early breast cancer, SIE-NSM-IRPI was comparable to C-NSM-IRPI, considering oncologic safety and detection of sentinel lymph nodes. It had a lower incidence of prosthesis removal, shorter incision length, and was associated with better patient satisfaction with the breasts. More random clinical trials of this novel approach in a larger cohort of Chinese patients with an extended follow-up period are needed in the future.
Single-port endoscopic-sentinel lymph node biopsy combined with indocyanine green and carbon nanoparticles in breast cancer
BackgroundIn order to explore the surgical safety and the reliability of axillary staging of single-port endoscopic-sentinel lymph node biopsy, we combined it with indocyanine green that was excited by near-infrared fluorescence endoscopy and carbon nanoparticles as a tracer and compared this method to conventional open sentinel lymph node biopsy.MethodsThis is a retrospective and observational study, there were 20 patients in each group and the total sample size was 60: Group 1, single-port endoscopic-sentinel lymph node biopsy combined with indocyanine green and carbon nanoparticles; Group 2, single-port endoscopic-sentinel lymph node biopsy with carbon nanoparticles only; Group 3, conventional sentinel lymph node biopsy with indocyanine green and carbon nanoparticles. Sentinel lymph node detection and upper extremity function were determined to measure the safety and efficacy of the novel single-port endoscopic-sentinel lymph node biopsy (SPE-SLNB) technique to the standard conventional sentinel lymph node biopsy technique.ResultsThe detection rate of sentinel lymph nodes was 100% in Group 1, 100% in Group 2, and 95% in Group 3. There were no significant differences in upper arm function and pain scores between the three groups.ConclusionThe novel technique of combining indocyanine green and carbon nanoparticles with single-port endoscopic-sentinel lymph node biopsy achieved a similar detection rate and mean number of sentinel lymph nodes as conventional sentinel lymph node biopsy. Traditional open surgery requires two different incisions for breast surgery and SLNB. While the most important advantage of SPE-SLNB is that two procedures can be effectively performed through a single-port in the axilla Therefore, for patients who meet the indications, single-port endoscopic-sentinel lymph node biopsy is as safe and reliable as conventional sentinel lymph node biopsy but has the aesthetic advantage of only one incision.
Microstructural evolution of Al-Si coating and its influence on high temperature tribological behavior of ultra-high strength steel against H13 steel
Al-Si coated ultra-high strength steel(UHSS)has been commonly applied in hot stamping process.The influence of austenitizing temperature on microstructure of Al-Si coating of UHSS during hot stamping process and its tribological behavior against H13 steel under elevated temperature were simulatively investigated.The austenitizing temperature of Al-Si coated UHSS and its microstructual evolution were confirmed and analyzed by differential scanning calorimetry and scanning electron microscopy.A novel approach to tribological testing by replicating hot stamping process temperature history was presented.Results show that the hard and stable phases Fe_2Al_5+FeAl_2 formed on Al-Si coating surface after exposure to 930°C for 5 min,which was found to be correlated to the tribological behavior of coating.The friction coefficient of coated steel was more stable and higher than that of uncoated one.The main wear mechanism of Al-Si coated UHSS was adhesion wear,while abrasive wear was dominant for the uncoated UHSS.